全髖假體 的英文怎麼說

中文拼音 [quánkuānjiǎ]
全髖假體 英文
total hip prostheses
  • : Ⅰ形容詞1 (完備; 齊全) complete 2 (整個) whole; entire; full; total Ⅱ副詞(完全; 都) entirely...
  • : 名詞(髖部) hip
  • : 假名詞1. (按照規定不工作或不學習的時間; 假期) holiday; vacation 2. (經過批準暫時不工作或不學習的時間; 休假) leave of absence; furlough
  • : 體構詞成分。
  1. Safe fixation location of screw of acetabulum pseudarthrosis

    螺釘固定安位置的確定
  2. Implants for surgery - wear of total hip - joint prostheses - part 1 : loading and displacement parameters for wear - testing machines and corresponding environmental conditions for test

    外科植入物.關節的磨損.第1部分:試驗用磨損試驗機和相應環境條件的負荷和位移參數
  3. Domestic magnesium - silicon jade total hip prosthesis has too low head - neck ratio to result in enough range of motion that fulfilled daily living after total hip arthroplasty

    國產鎂硅玉全髖假體由於頭頸比太小,在任何安置方位內其活動范圍都較小,將難于滿足日常生活需要。
  4. Method : in this study the author established a three - dimensional computerized model of hip joint and tested the range of motion of three different head - neck ratio after total hip arthroplasty

    方法:應用計算機模擬技術建立人工關節三維計算機模型,模擬測試三種不同頭頸直徑比全髖假體外不同安置方位的活動范圍。
  5. Between october 2003 and 2005 june, the authors performed 37 hip anatomic cementless tha in 35 patients with different clinical cases. twenty - five tha in 24 patients with the conventional methods were followed up for average of 18 months

    2 .回顧性分析了未使用模板進行的解剖型非骨水泥固定股骨的24位患者共25例關節置換術,術后進行了平均18個月的隨訪。
  6. The patients were evaluated with harris hip score and radiographic analysis. results : dr - based surgical planning software had better proximal fit on postoperative x rays than the conventional method. in the clinical results the harris hip score using both methods was not significantly different between patients, 94. 5 % of patients had excellent or good results evaluated by harris hip scores post - operation

    再利用開發的基於數字x線股骨置換術前計劃軟對11位患者共12例術前預估后進行關節置換術,術后進行平均9個月的隨訪,上述兩組均通過harris評分及x線片評價臨床效果。
  7. Standard specification for total hip joint prosthesis and hip endoprosthesis bearing surfaces made of metallic, ceramic, and polymeric materials

    金屬陶瓷和聚合材料制關節部內用軸承表面的標準規范
  8. Implants for surgery. partial and total hip joint prostheses. part 5 : determination of resistance to static load of head and neck region of stemmed femoral components

    外科植入物.部分和關節.第5部分:有柄元件對頭和頸靜態負載
  9. Result : range of motion after total hip arthroplasty depended on design parameters such as head - neck ratio, but also on the implantation parameters such as the cup ' s inclination and antevertion, the stem ' s antevertion and their combination of each other

    結果:關節置換術后的活動范圍不僅取決于設計的某些參數,如頭頸直徑比,還取決于安置的某些參數,如臼杯的外展角和前傾角,柄的前傾角,以及臼杯和柄的相互方向等等。
分享友人