接地中性點 的英文怎麼說
中文拼音 [jiēdezhōngxìngdiǎn]
接地中性點
英文
grounded neutral- 接 : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
- 性 : Ⅰ名詞1 (性格) nature; character; disposition 2 (性能; 性質) property; quality 3 (性別) sex ...
- 點 : Ⅰ名詞1 (液體的小滴) drop (of liquid) 2 (細小的痕跡) spot; dot; speck 3 (漢字的筆畫「、」)...
- 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
-
The selection of neutral - point earthing ways of the hydrogenerator of left - bank power station in the three gorges project should be related to one - point earthing protection of the stator of its generator within one hundred percent framework
三峽工程左岸電站水輪發電機中性點接地方式的選擇應和發電機100 %范圍定子一點接地保護相關聯。New designed auto tracing arc eliminating device based on this technique contents more technology, which has sample circuit, wide tuning scope, quick response and low noise. this paper firstly introduces neutral grounding histroy. by analyzing the syntony grounding theory, the transient and stable process of one - phase grounding fault, the threaten to secure run of power system and the importance of exact compensation for capacitive current are cognized
論文中首先介紹了中性點接地方式的發展過程,通過對諧振接地原理和單相接地故障的暫態、穩態分析,認識到接地故障對系統安全運行的危害,通過消弧線圈對接地電容電流的迅速準確補償是減小故障危害的最主要手段。Analysis of ungrounded neutral ac electric network insulation fault
中性點不接地交流電網絕緣故障分析Specification for neutral - to - earth resistance in distrbution system
配電系統中性點接地電阻器To resolve the situation that the sensitivity of present ground fault protection schemes is low for the large - sized hydro - generators, a kind of protection scheme based on the fault component of third - harmonic voltage and two kinds of protection scheme based on the fault component of zero - sequence voltage at the terminals and neutral are developed, and they can obtain higher sensitivity and reliability and provide 100 % protection for the stator windings. the influence of noise on the stator ground fault protection based on the local modulus maximum of wavelet transform is analyzed
針對目前大型水輪發電機定子繞組單相接地保護靈敏度偏低的問題,通過分析單相接地故障后機端和中性點零序電壓的變化特點,提出了一種基於機端和中性點三次諧波電壓故障分量和兩種基於機端和中性點零序電壓故障分量的高靈敏度、高可靠性保護方案,並實現定子繞組的100 %保護。On the grounding manners of neutral point in distribution networks
關于配電網中性點接地方式的探討Choice of grounding method of neutral point in high voltage distributing net
高壓配電網中性點接地方式的選擇Small current grounding power system is a popular neutral grounding mode around the world and is widely used in our country
配電網中性點採用小電流接地在世界范圍內是一種較流行的接地方式,並在我國配電網中得到了廣泛應用。Therefore, the conclusion is valuable to engineering apply, and could be consulted for the selection of the neutral point grounding mode of the civic 10kv network
得出的這些結論具有相當的工程實用價值,為大城市10kv電網中性點接地方式的選擇提供了一定的參考依據。Wavelet analysis theory and its application in power system have been introduced briefly. this paper gives a general overview of various neutral grounding modes. some existing theories schemes on the fault line selection have been summarized systematically
文中簡要介紹了小波分析的理論基礎及其在電力系統中的應用現狀,概述了配電網中性點各種接地方式的優劣,系統歸納了現有的各種選線原理和方案的特點,提出了尚需解決的問題,並給出了分析的結論。The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。Moreover, the epiipc functions properly and stably under well due to the reasonable electrical circuit design and very strong anti - jamming design. this design successfully solves the directionally power current leakage fault action and reject action, and makes it working in both neutral point non - grounded and grounded through resistors or coils under compensate systems and over compensate systems
本次研製的保護器較好地解決了功率方向型漏電的誤動作和拒動作問題,使得它既能較好地運行在中性點不接地的系統中,又能用在中性點經消弧線圈接地的欠補償系統中,同時試用於過補償系統中。The calculation of the selection of the neutral - point earthing - transformer of the generator shows that the selection of its parameters should be matched with one - point earthing protection of the stator of its generator
對發電機中性點接地變壓器的選型計算表明,其參數選擇必須與發電機定子一點接地保護相配合。China ’ s 10kv distribution systems are almost grounded via the arc - suppression coil or not grounded systems
我國10kv配電網大部分是中性點經消弧線圈接地系統或者中性點不接地系統。Analysis of transient characteristics of signals phase earth fault in non - solidly earthed network
中性點非直接接地電網單相接地故障暫態特徵分析The unearthed or compensated neutral networks are mainly applied in our country ’ s distribution systems
我國城鄉的配電網,大多採用主變中性點非直接接地的小電流運行方式。In mode selection of middle and large capacity units nowadays, there mainly have two types of peterson coil grounding and distribution transformer with resistor
在現有大中型發電機中性點接地選擇上,主要有消弧線圈接地方式和接地變高阻接地方式。It has been proved by test results that this protective method is suitable not only for neutral point insulated system, but also for neutral point grounded system through arc suppression coil
實驗結果表明:該保護原理不僅適用於中性點絕緣的供電系統,而且適用於中性點經消弧線圈接地的供電系統,提高了選擇性漏電的動作可靠性,保證了動作值的穩定性。It depends on many factors. in our country, middle and low voltage distribute net system uses non - direct - grounded system including no - grounded system and anti - arc system
我國中低壓配電網多採用小電流接地系統,即中性點不接地或者經消弧線圈接地。After the neutral point is grounded through perterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc
中性點經消弧線圈接地后,有效減小了流過故障點的電容電流,減小了弧光接地過電壓,有利於電弧熄滅。分享友人