接地保 的英文怎麼說

中文拼音 [jiēdebǎo]
接地保 英文
ground protection
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ動詞1 (保衛; 保護) defend; protect 2 (保持) keep; preserve; maintain in good condition 3 (...
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  1. The selection of neutral - point earthing ways of the hydrogenerator of left - bank power station in the three gorges project should be related to one - point earthing protection of the stator of its generator within one hundred percent framework

    三峽工程左岸電站水輪發電機中性點方式的選擇應和發電機100 %范圍定子一點接地保護相關聯。
  2. So far, there has existed several kinds of theory of ground fault protection for field winding of generator. in these methods, pingpong bridge field ground protection is a simple and effective one

    目前已有多種原理的發電機勵磁迴路接地保護,其中乒乓式勵磁迴路接地保護是一種簡單有效的護原理。
  3. Protection equipment of generator stator earthing

    發電機定子接地保護裝置
  4. To resolve the situation that the sensitivity of present ground fault protection schemes is low for the large - sized hydro - generators, a kind of protection scheme based on the fault component of third - harmonic voltage and two kinds of protection scheme based on the fault component of zero - sequence voltage at the terminals and neutral are developed, and they can obtain higher sensitivity and reliability and provide 100 % protection for the stator windings. the influence of noise on the stator ground fault protection based on the local modulus maximum of wavelet transform is analyzed

    針對目前大型水輪發電機定子繞組單相接地保護靈敏度偏低的問題,通過分析單相故障后機端和中性點零序電壓的變化特點,提出了一種基於機端和中性點三次諧波電壓故障分量和兩種基於機端和中性點零序電壓故障分量的高靈敏度、高可靠性護方案,並實現定子繞組的100 %護。
  5. The ground faults in the generator stator are by far common faults to which generators are subjected. internal short - circuit faults, which may immediately damage generator, are always preceded by the ground faults. the possibility of internal fault and damages caused by it can be decreased largely if the stator ground fault protection reliably and sensitively operates

    定子繞組單相故障是發電機最常見的一種故障,而且往往是更為嚴重的繞組內部短路故障發生的先兆,定子繞組單相接地保護的可靠與靈敏動作可以大大降低內部短路故障的發生幾率,減少故障造成的損失。
  6. Therefore, the stator ground fault protection plays an important role in the protection system of generator. at present, the large - sized hydro - generators, such as the generators in three gorges power station, require that the stator ground protection must be with very high sensitivity, so that it is beyond the capacity of available protection schemes

    定子繞組單相接地保護是大型發電機繼電護系統中十分重要的一項內容,而現有護方案難以滿足目前大型水輪發電機(如三峽電站機組等)不斷提高的定子繞組單相接地保護靈敏度要求。
  7. Guide for temporary protective grounding systems used in substations

    變電所臨時接地保護系統用指南
  8. Guide for generator ground protection

    發電機接地保護指南
  9. Specification for a. c. voltage - operated earth - leakage circuit breakers

    交流電壓控制的接地保護斷路器規范
  10. Stator earth - fault protection relay

    定子接地保護繼電器
  11. Specification of single phase earthed relay in non - effective earthed power system

    電流系統單相接地保護裝置
  12. On the protection of commutator of the electria e - quipment earthing at underground mines

    淺論下礦山電氣設備的接地保護技術
  13. The application of power leakage protection device in various ground protection system

    漏電護裝置在不同接地保護系統中的應用
  14. Watertight two - pole plug with earthing contact ; 10a 250 v d. c., 16a 250 v a. c

    接地保護觸點的防水的兩極插頭.直流10a 250 v ,交
  15. When the wave wells up the regulation that the voltage is greater than the gas and in charge of, gas in charge of discharge earth connection too high voltage, protect the apparatus systematically

    當浪涌電壓大於氣體管的規定時,氣體管會將過高的電壓放電護系統器材。
  16. The calculation of the selection of the neutral - point earthing - transformer of the generator shows that the selection of its parameters should be matched with one - point earthing protection of the stator of its generator

    對發電機中性點變壓器的選型計算表明,其參數選擇必須與發電機定子一點接地保護相配合。
  17. Generally, single phase grounding fault can cause both high phase current and zero sequence current. proper grounding protection set can act reliably and cut off fault

    一般,單相短路將產生很大的故障相電流和零序電流,相應的接地保護裝置將能可靠動作從而將故障切除。
  18. This paper is focused on the operation of single - phase earthprotection for little earth current system. based on the analyses for several kinds of ground protections, one ground protection with the functions of line selection and ground positioning is proposed for the complex automatic and mordern management for the electric substation. by this means, the economic, reliability, safty and stable operation for the grid can be achieved

    針對小電流系統單相接地保護的運行進行了論述,並分析比較了幾種目前採用的小電流系統單相接地保護的功能及優缺點,建議採用一種既能選線又能定位的小電流系統單相接地保護裝置,以適應綜合自動化和現代化管理的需要,確系統經濟、可靠、安全、穩定運行。
  19. Arc - grounding fault line selection is the paper ' s key point and innovative point about small current grounding power systems. a lot of simulations are made based on the change rule and the character of fault voltage, fault current. the simulation study declare that the use of the method of wavelet analysis can select the fault line when the arc - grounding fault take place, it will play a important directive role in the research of the protection equipment

    對小電流系統電弧故障的選線模擬是本文的重點,也是一個創新點,本文從研究的角度,在深入分析電弧時故障電壓、電流的特點和變化情況的基礎上,進行了大量的選線模擬,模擬表明電弧故障時,小波分析方法也能準確選出故障線路,這對研製高性能的接地保護裝置將起到重要的指導作用。
  20. Under the conditions of high safe coefficient of insulated electrical strength of the stator winding of the generator, the selection of earthing resistance value should meet the needs of matching one - point earthing protection of the stator and limiting the fault current

    在發電機定子繞組絕緣電氣強度有較高的安全系數的情況下,電阻值的選取應主要服從與定子一點接地保護的配合及限制故障電流的需要。