接地變壓器 的英文怎麼說

中文拼音 [jiēdebiàn]
接地變壓器 英文
earthing transformer
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : 壓構詞成分。
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  1. The products is of high water hydrophobe device usedin suitable and has the characteristics of aging resistance, resistance, tracking resistance, and corrosive resistance. it can withstand high bent load, strong impact force fn12 - 12 series indoor use high voltage load switch fn12 - 12 and fn12 - 12r is of three phases indoor use ac high voltage load switch for breaking and making the circuit of 50hz, 12kv system under rated loading

    Fn12 - 12和fn12 - 12r組合電是額定電12kv額定頻率50hz的三相高開關設備用於分合負荷電流閉環電流空載和電纜充電電流關合短路電流配裝開關的負荷開關,可以承受短路電流
  2. The second, at the high frequency primary coil, when switch turn on with control signal ( the spwm pulse is modulated ), in the positive or negative semi - period of low frequency modulation signal, transformer coil with same direction voltage. the magnetic flux of transformer core will increase step by step. at the end, it leads to magnetic flux saturation

    二、在高頻原邊,當開關管收控制信號脈沖列(經調制的spwm波列)導通時,在低頻調制信號的正半周或負半周內,施加在繞組上的是同一方向的電磁芯中的磁通可能將級進逐漸增加,導致磁芯飽和,造成磁偏或單向磁化,導致低頻電信號放大失真或由於很大的磁化電流而無法正常工作。
  3. This paper presents the way to configurate the distribution transformer, and the setting method for the stator earth fault protection with the example of hubei tiantang pump - storage power plant

    針對配電裝置提供了一套較完整的配置和整定計算方法,並結合湖北天堂抽水蓄能電站的實例進行計算, ?此類方式提供了可借鑒的方法。
  4. Guide for the grounding of instrument transformer secondary circuits and cases

    儀表用次級線圈電路外殼指南
  5. Sometimes the capacitor is inserted between the anode and the transformer ( as shown in the schematic above ), and sometimes the transformer is connected directly to the anode, and the capacitor inserted in the ground lead

    有的時候耦合電容在屏級和輸出之間(如圖原理圖所示) ,有時耦合到屏級,而電容則連在到端。
  6. As the step - down transformer has no load when the scr is turned off, the system is stable during switching. less transformers, small area the device occupies, the relative simplicity of connection are the other advantages

    這種補償方案由於在晶閘管關斷時降相當于空載,不存在暫態過程的不穩定問題;所用的數目少;佔面積較少;線相對較簡單。
  7. Technology parameter of dksc earthing transformer

    Dksc系列接地變壓器
  8. The basic principle of earthing transformer is analysed. a proper capacity calculation method for earthing transformer is introduced. the calculation example is given too

    分析了接地變壓器的基本原理,介紹了一種比較合理的接地變壓器容量計算方法,並給出了計算實例。
  9. Leeec may produce the special transformer according to the clients requirements including : commutate transformer ; furnace transfo - rmer ; earthing transformer ; isolation transformer

    遼寧易發式電氣設備有限公司可根據客戶需要,生產各種電等級特種,主要有整流電爐接地變壓器隔離等。
  10. The calculation of the selection of the neutral - point earthing - transformer of the generator shows that the selection of its parameters should be matched with one - point earthing protection of the stator of its generator

    對發電機中性點接地變壓器的選型計算表明,其參數選擇必須與發電機定子一點保護相配合。
  11. In the second chapter, equivalent circuit of the eddy current sensor is firstly analyzed. based on that, the carrier signal generating circuit that is realized by the lc periodic circuit is introduced, thus, the carrier signal of standard frequency is obtained through the trimming capacity. subsequently, the disc type rotational armature generator and the rotational coupling transformer are separately leaded in to realize the power supplies of the carrier signal generating circuit and output of the measuring signal

    在傳感設計一章中,首先對渦流傳感進行等效電路分析,在此基礎上分析了由電感、電容諧振電路構成的載波信號發生電路,並通過微調電容獲得了標準頻率的載波信號;下來提出了採用盤式旋轉電樞發電機解決載波信號發生電路電源供給問題的方案,同時通過旋轉耦合的引入,使得測量信號輸出問題很好解決;本章最後給出的一組實驗曲線充分說明了這一方案的可實現性。
  12. The reactive power optimization compensation is to find the suitable compensation place and the best compensation capacitance by adjusting the generator bus voltages, transform taps and reactive compensation capacities in the condition of satisfying power load requirement, which can guarantee the secure and high quality power for consumers. the improved genetic algorithm is applied in this thesis according to the features of reactive power optimization of high voltage transmission bus, which are the non - linear problems with multi - variables and multi - restrictions

    電網無功優化補償是在有功潮流調度給定的情況下,以負荷節點電和線路輸送無功功率作為狀態量,運用優化演算法,調節發電機節點電可調分頭和無功補償裝置,在滿足電力負荷的要求下,尋求合理的無功補償點和最佳補償容量,保證電網能夠安全、優質向用戶供電。
  13. Based on the analysis of the paper, we can draw the conclusion that this device has several issues to be solved to put into use, such as low filtering capacity, large bulk and area the device occupies, complexity of connection, and the hazard of ferro - resonance existing when switching without disconnecting the circuit of the step - up transformer

    經過分析發現,這種補償方案存在一些問題,如濾波能力低,補償裝置體積大,佔面積多,線復雜;並且如果在投切過程中不將升側迴路斷開,存在著發生鐵磁諧振的危險。
  14. Though standard cast resin dry - type transformers can meet the demands of most consumers. we still have to proceed special designing of transformers for special application field and operating conditions, such as single phase transformers, regulating transformers with onload tap changer, double voltage transformers, isolating transformers, rectifying transformers, earthing transformers and transformers with special tapping arrangement, which we are supplying to consumers all over the country

    雖然標準的樹脂絕緣乾式已能滿足大多數用戶的要求,但是對于某些特殊的應用領域與使用條件仍需我們進行特殊設計。諸如單相有載調雙電換隔離整流以及有特殊出線排列的,我公司在不斷提供給各的用戶。
  15. Making use of the idea of the parallel genetic algorithms, presenting the adaptive multiple subpopulation evolutive strategy. presenting extinction and immigration strategy in order to avoid the similar or even same individuals appear. in order to enhance convergence velocity of reactive power optimization of the radial distribution system, combining the characteristic of the radial distribution system, a sensitivity analysis approach was build up for optimal selection of capacitors and mutation of transformer tap changer

    為了提高配電網無功優化的收斂速度,結合配電網的特點,提出採用簡單可行的靈敏度公式選擇無功電容補償的安裝點,並用靈敏度分析頭,使異運算元的選取更符合配電網無功優化問題中關于調節頭的實際情況,減少了一些不必要的異運算,使適應性和魯棒性加強;根據實際情況採用無功補償電容的啟發式異,使異運算元的選取更符合無功優化問題中關于補償電容的實際。
  16. Underground - type, self - cooled, single - phase, distribution transformers with separable insulated high - voltage connectors ; high voltage 25 000 v and below ; low voltage 600 v and below ; 167 kva and smaller

    有可分離絕緣高下型自冷式單相配電:高25000v及以下低600v及以下167kva及更小的
  17. 24940grdv 14400v 240 120v, 167kva transformers - underground - type, self - cooled, single - phase distribution transformers with separable, insulated, high - voltage connectors ; high voltage 24 940 grdy 14 400 v and below and low voltage 240 120 v, 167 kva and smaller

    .帶可分離絕緣高下型自冷式單相配電.高
  18. A manufacturer will often require that an isolation transformer be connected in front of their equipment, and that their equipment be connected to a separate, isolated ground

    他們經常要求在他們的設備前連一個隔離的,他們的設備要連到一個獨立、隔離的點。
  19. Traction transformers are important devices in electric railways system, and secure operation has significant influence on the stability of electric railways system

    =牽引是鐵道電氣化系統中重要的電氣設備,在電氣化鐵道系統中佔有極其重要的位,它的安全運行與否,直關繫到鐵道電氣化系統能否連續穩定的工作。
  20. According to the characteristic of nine - area diagram of substation vol / var coordinated control, this system gives the defination of fuzzy sets and the degree of membership of input / output variables, and designs corresponding control rules. the results of simulation demonstrate the system can satisfy the constrains of the day - adjusting times of the switching of on - load transformer and paralleled compensation capacitors, and ensure voltage quality, reactive power basical balance. considering the var requirement in different load time period and the control demand in load saltation, a improved control scheme is provided. the results of simulation show the improved scheme can meet the demand of vol / var in different load time period, protect the wrong operation when either voltage or reactive power appears saltation, and decrease the times of regulation of the switching of on - load transformer and paralleled compensation capacitors finally, a background software module of substation vol / var coordinated control is designed, based on the supervisory control and data acquisition system of substation

    模擬結果證明該系統能在各種負荷條件下確保電合格和無功基本平衡,且能滿足電站對有載調頭日調節次數和並聯補償電容組的日投切次數的限制。通過考慮不同負荷時段對無功功率的需求和負荷突情況下的控制要求,對上述模糊控制策略進行了改進,模擬結果證明改進后的控制策略能滿足不同負荷時段對電和無功的要求、抑制電或無功突情況下的誤動作,且有效減少了有載調頭和並聯補償電容組的調節次數。最後基於電站scada系統設計了一后臺電無功綜合控制軟體模塊。
分享友人