接地電極 的英文怎麼說

中文拼音 [jiēdediàn]
接地電極 英文
earth electrode
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : i 名詞1 (頂點; 盡頭) the utmost point; extreme 2 (地球的南北兩端; 磁體的兩端; 電源或電器上電流...
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  • 電極 : electrode; pole
  1. Furthermore, problems easy to make mistake are demonstrated, for instance, grounding resistance of large grounding grid is impedance

    研究論證了被一些研究者錯誤理解的關于大型阻是阻抗、四法及其倒相法測量結果為阻抗等問題。
  2. This paper presents the performance of metal oxide anode material, deployment and configuration of anode ground bed, and makes contrast of grounding resistance and protective potential between metal oxide anode and duriron anode

    文章介紹了金屬氧化物陽材料的性能、陽床的布置及結構,並對比了金屬氧化物陽與高硅鑄鐵陽阻和保護位。
  3. On the other side, measuring errors of grounding resistance and solution of current voltage electrodes reversing has been compared with horizontal two layers and vertical delaminating ( three layers soil )

    比較分析了反向布置、在水平雙層和垂直分層或三層土壤結構中阻測量的誤差和解決辦法。
  4. The influences of vertical grounding electrodes on grounding resistance, step and touch voltages were analyzed numerically

    採用數值計算方法分析了垂直系統的阻、壓及跨步壓等的影響。
  5. It creates the model of layer soil by using the cdegs software, analyses the resistance error which is measured by traditional three - poles way, measures the grounding grids resistance and soil resistance rate of hejin power plant, creates the electromagnetic model of layer soil and grounding grids model of hejin power plant, calculates the step voltage > touch voltage n voltage distribution of earth surface in fault of hejin power plant. in the end, it compares the measuring value and calculating value of grounding grids resistance in hejin power plant

    本文利用cdegs軟體建立分層土壤模型,對傳統三法測量阻誤差進行分析;對河津阻和土壤阻率進行測量;建立河津廠分層土壤磁模型和網模型;計算河津阻和事故狀態下跨步壓、壓和位分佈;最後對河津阻實測值與計算值進行比較分析。
  6. The results show that the vertical grounding electrodes can effectively decrease grounding resistance, step and touch voltages of the grounding system and reduce the influence of seasonal factors on the grounding system

    分析表明,增設垂直能有效減低系統的阻、減小發變站的壓和跨步壓、減小季節因素對網安全性的影響。
  7. Products : rectifers, high silicon cast iron anodes, mmo anodes ( rod, tubularribbon ), titanium conductor bar, sacrificial anodes ( aluminum, magnesiumzinc ), magnesiumzinc ribbon anodes, zinc grounding cell, reference electrodes, test postjunction boxes, thermite ( corrtech exothermic weld metal ) mold, cathodic protection system utilizing solar energy, cp data remote monitoring system, and other accessories

    我們的產品:恆位儀、高硅鑄鐵陽、鈦基混合金屬氧化物陽(帶狀、棒狀、管狀) 、鈦導片、鋅合金陽、鎂合金陽、鋁合金陽、鋅帶鎂帶、長效硫酸銅參比、高純鋅參比、鋅池、陰保護測試樁、鋁熱焊模具和焊劑、太陽能陰保護系統、陰保護參數遠程監測控制系統等全系列陰保護系統配套產品。
  8. Must arrange earthing poles in a side of the base or it around. the earhting resisance should be less than 4ohm to assure that the connent rain water from entering cable room

    必須在組變基礎一側或四周布好阻值應小於4歐姆,並應確保組合式變站與作可靠連
  9. Sy - kang shen, bor - chyun wang, ching - yin lee and tsung - chih lin, “ a modified qft design method for a cascaded multiple loop system and application in idle speed control ”, 1999 international symposium on quantitative feedback theory and robust frequency domain methods, pp. 25 ~ 41, university of natal, durban, south africa, august, ( 1999 )

    [ 22古碧源,李清吟,顏坤鴻,楊仲健,林春福, "二捷運直流供系統之位與雜散流, "第十九屆力工程研討會論文集,第677至681頁, ( 1998 )
  10. Leakage current is one of key factors for the energy resolution of the detectors, the mis detector has lower leakage current thus improve the energy resolution. the mis structure is a good contact type for the cdse detectors

    可見漏流是影響探測器能量解析度的重要因素,具有mis的探測器能有效減小漏流,提高能量解析度,因而是cdse探測器的一種較佳觸方式。
  11. In the 3 ~ 35kv power supply system of our country, the large part is the not solidly earthed neutral system. when the single - phase earthed phenomena happens in this system, this electric power network can run with failure. and in this way the operated cost can reduce greadty. and at the same time the power supply systemic dependability can be improved. but when the single - phase earthed current is large, this electric power system can engender easily arc earthed overvoltage and interphase short circuit by this means

    在我國10 35kv供系統中,主要為中性點非直系統,這種系統在發生單相時,網仍可帶故障運行,這樣可以大大降低運行成本,提高供系統的可靠性,但這種供方式在單相流較大時容易產生弧光壓和相間短路,給供設備造成了大的危害。
  12. If you were to leave a grounded cable stationary in an energized high - frequency electrode for a while, you would notice that the insulation is noticeably warmer where it made contact with the corona field

    如果我們將一根纜穩定放在施以高頻壓的中一會兒?你將注意到與暈有觸的絕緣部分有明顯的變熱。
  13. Recurring to rnathematic figure and examples and aiming at such questions as unbalanced current and induced voltage and high frequency interference, this paper has not only researched anti - jamming ability and measuring process of both three - electrode method and four - electrode method which are combined with reverse phase method, but also summarized actual measuring experiences

    通過數學推導和實例,圍繞消除網不平衡流、引線問互感壓、高頻干擾等問題,分析了三法、四法結合倒相法測量阻的抗干擾能力和測量過程,並總結了實際測試經驗。
  14. Foundation earth electrode

    接地電極
  15. Besides, it has been proved that four - electrode method is suitable for measurement of grounding resistance, which disposes current electrode and voltage electrode according to triangle. finally this paper has corrected one wrong parlance that inherent error exists in four - electrode method

    通過理論和實踐證明了四法適用於流、按三角布置測量阻,並糾正了其他文獻關於四法存在固有誤差的問題,得出四法的固有誤差和三法一致的結論。
  16. Supplementary ground electrode

    補助接地電極
  17. When protecting a building it is permitted to install a separate grounding electrode for special equipment ? if an equipment manufacturer requires this, how do we deal with this problem

    當保護一幢建築時,允許給特殊的設備安裝一個分開的接地電極嗎?如果設備的製造商要求這樣做,我們如何處理這個問題?
  18. Lwy : when protecting a building it is permitted to install a separate grounding electrode for special equipment ? if an equipment manufacturer requires this, how do we deal with this problem

    當保護一幢建築時,允許給特殊的設備安裝一個分開的接地電極嗎?如果設備的製造商要求這樣做,我們如何處理這個問題?
  19. Material and minimum dimensions of earth electrodes with respect to corrosion

    防銹接地電極的材料和最小尺寸
  20. ( 1 ) with the principle of measuring resistance, the paper carries through the theory analysis about possibility of measurement method with short electrode wire

    具體工作包括:從阻的測量原理出發,討論了採用短引線測量阻的可行性。
分享友人