接地電阻計 的英文怎麼說

中文拼音 [jiēdediàn]
接地電阻計 英文
earth resistance meter
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • : Ⅰ動詞1 (計算) count; compute; calculate; number 2 (設想; 打算) plan; plot Ⅱ名詞1 (測量或計算...
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  • 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
  1. According to the topology of the substation and resistance measurements of down - leaders, the erosion diagnosis equation is built and the resistance variations of grounding grid branches are solved, and the erosion of grounding grid could be found through the fuzzy diagnosis regulation

    利用網拓撲結構圖及網引下線間的測量值,建立腐蝕診斷方程,通過求解診斷方程,算出網支路值變化量,採用模糊診斷方法判斷出網導體腐蝕的情況。
  2. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv故障的形式、消弧線圈的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值算模型,在考慮了流變化、中性點取值大小、值變化等多種影響因素的情況下,對中性點經消弧線圈和經小方式下網的過壓水平和點短路流大小進行了數值算,其算結果與科院所作現場試驗進行了比較。
  3. The influences of vertical grounding electrodes on grounding resistance, step and touch voltages were analyzed numerically

    採用數值算方法分析了垂直極對系統的壓及跨步壓等的影響。
  4. It creates the model of layer soil by using the cdegs software, analyses the resistance error which is measured by traditional three - poles way, measures the grounding grids resistance and soil resistance rate of hejin power plant, creates the electromagnetic model of layer soil and grounding grids model of hejin power plant, calculates the step voltage > touch voltage n voltage distribution of earth surface in fault of hejin power plant. in the end, it compares the measuring value and calculating value of grounding grids resistance in hejin power plant

    本文利用cdegs軟體建立分層土壤模型,對傳統三極法測量誤差進行分析;對河津和土壤率進行測量;建立河津廠分層土壤磁模型和網模型;算河津和事故狀態下跨步壓、壓和位分佈;最後對河津實測值與算值進行比較分析。
  5. Electronic co., ltd., a private hi - tech company, professionally makes and markets electronic instruments and gauges, such as digital torque tester, bottle cap torque tester, voltage resistance tester, grounding resistance tester, leakage current tester, insulation resistance tester and etc. lankers quality instruments and gauges are characterized by well - designed structure, high reliability and stability and outstanding performance and are well sold to users in the industries of home appliances, motorcycle, automobile, motor and pharmaceutical

    市藍光子有限公司是一家集科研生產銷售於一體的高科技民營企業,公司擁有雄厚的技術實力,以卓越的設能力,完備的工藝控制和完善可靠的檢測手段,向用戶提供高性價比的子測量儀器。主要產品有:數字扭力測試儀系列瓶蓋扭力測試儀系列耐壓測試儀,測試儀,泄漏流測試儀,絕緣測試儀等安規測試儀系列。
  6. The synchronous rectifying and low power sampling technology is used to reduce the power consumption, flexible external loop compensation, error amplifier output clamp are adopted for better system large signal response. the piecewise slope compensation technology is employed to minimize the consequence of over compensation. the sensor resistor is externally connected, which realize output voltage programmable. the overheat protection and under voltage protection modules are integrated in the die to allow the reliable operation of the system

    同時,路設採用同步整流技術、低功耗流采樣技術降低功耗,提高轉換效率;採用靈活的外部環路補償技術、誤差放大器輸出嵌位技術以實現良好大信號特性;採用分段斜坡補償技術,消除不穩定因素,並最大程度減小過補償帶來的問題;採用外輸出采樣的方式,實現輸出壓的可編程。
  7. Applying relative arithmetic to all kinds of faults and calculating off - line, we can master time - distance relation chart for all kinds of faults. computation indicates : when transmission lines occur faults, the data window of protection algorithm consisting of prefault and postfault data at the same time has important significance. the following methods are useful to achieve the inverse time characteristic : calculating impedance by using flourier in a full cycle, calculating work voltage by using fault component, calculating the torque created by a phase comparator or a magnitude comparator

    實際的算表明:輸線路發生故障后,用故障前後的數據同時充滿保護演算法的數據窗,對于快速切除近區故障具有很重要的意義;同時利用故障前後的數據,下述方法可以比較好實現距離保護的反時限特性:直用全周傅里葉演算法進行算;採用工頻變化量抗繼器進行工作壓的算;採用轉矩的思想進行轉矩的算。
  8. In connection with the situation of application of hook type earthing resistance meter in the transmission division of yichang power supply bureau, taking account of the principle and the environmental requirement of measurement, the problems in application were proposed and analyzed as well. according to the different grounding structure of lightning protection for overhead transmission lines, the proper measuring method was suggested

    針對宜昌供局輸分局鉤式接地電阻計使用情況,通過運用該表測量原理和適用條件,分析並提出使用中存在的問題;對架空送線路防雷構造差異情況,提出正確的測量方法。
  9. In the deregulated power market , the power grid operator is facing many uncertainty and risks risk concept , risk analysis approach and risk management are introduced in chapter ii , the maj or risks of grid operators is analyzed and evaluated in details based on the real situation and data of yueyang city, hunan province , the economic risk resulting from the uncertainty of load prediction of whole system , generation capacity and parallel quantity of the large enterprises self - owned power plant are analyzed meanwhile , the increase of large enterprises self - owned power plant may cause economic and security risks considering different risk , the qualitmive and quantitative approaches are respectively adopted the direct and indirect congestion risks are evaluated based on probabilistic theory and decision theory the retail pricing and trade modes are major areas embracing risks as well chapter iii divides the risks in internal and external ones based on the characteristics of risk and put forward the layered risk management approach

    詳細分析和論述了網經營企業面臨的各種風險。基於湖南省岳陽力市場的實際情況和多年歷史數據,採用定性分析和定量算的手段具體分析了負荷、自備廠發量和上網量預測不確定性以及自備廠的大量增加給網企業帶來的經濟性風險和安全性風險。無論是長期還是短期,塞不僅會對網造成直風險,還可能造成間風險。
  10. Aim at the dtc ' s blemish mentioned above and the direction of dtc technique development, the dissertation put great emphasis on the work as follows, with an eye to exalt dtc system function : ( 1 ) a new speed - flux observer of an induction motor is proposed to enhance the accuracy of flux observing, which is an adaptive closed - loop flux observer and different from the traditions. a new adaptive speed - observation - way is deduced out according to the popov ' s stability theories ; ( 2 ) to improve the performance of dtc at low speed operation, we have to exalt the accuracy of the stator flux estimation and a new way of bp neural network based on extended pidbp algorithm is given to estimate and tune the stator resistance of an induction motor to increase the accuracy of the stator flux estimation ; ( 3 ) digital signal processor is adopted to realize digital control. an device of direct torque control system is designed for experiment using tms320lf2407 chip produced by ti company ; ( 4 ) bring up a distributed direct torque control system based on sercos bus, sercos stand for serial real time communication system agreement which is most in keeping with synchronous with moderate motor control ; ( 5 ) the basic design frame of the hardware and software of the whole control system is given here and some concrete problem in the experiments is described here in detail

    針對上面提到的直轉矩控制的缺陷和未來直轉矩控制技術發展方向,本論文重點做了以下幾個方面的工作,目的在於提高dtc系統的綜合性能: ( 1 )提出一種新型的速度磁鏈觀測器,新型的速度磁鏈觀測器採用自適應閉環磁鏈觀測器代替傳統的積分器從而提高磁鏈觀測的精度,並且根據popov超穩定性理論推導出轉速的新型自適應收斂律; ( 2 )改善系統的低速運行性能,主要從提高低速時對定子磁鏈的估精度入手,提出了一種提高定子磁鏈觀測精度的新思路? ?利用基於bp網路增廣pidbp學習演算法來實時在線修正定子參數; ( 3 )採用數字信號處理器dsp實現系統全數字化硬體控制,結合ti公司生產的tms320lf2407晶元,設了直轉矩控制系統的實驗裝置; ( 4 )提出了基於sercos總線網路化分散式的直轉矩控制系統, sercos ( serialrealtimecommunicationsystem )是目前最適合同步和協調控制的串列實時通信協議; ( 5 )基本勾勒出整個控制系統的硬體和軟體設基本框架,詳細描述一些實驗中的具體的細節問題。
  11. In general, the highest bearable force should be selected to minimize contact resistance ; however, spring contact force can be modified easily by changing the internal spring design and / or material, or simply changing the compressed mechanical height at which the contact finishes

    一般而言,最大可承受力的選擇應最大程度減少;但是,彈簧觸力可輕易通過更改內部彈簧設和/或材料,或者簡單更改壓縮機構觸高度來更改。
  12. Since it is immune to load change, immune to the value of grounded resistance change and its parameters can be easily measured, the fault location algorithm can be widely applied to the power distribution networks

    基於此論文還編制了單相故障定位的算機通用程序。該測距演算法不受負載參數變化的影響,不受過渡值大小的影響。
  13. Firstly, we analyze the transient and steady character of single phase high - impedance grounding fault. secondly, based on wavelet analysis on checking mutational signal and direction high frequency protection theory, utilizing zero sequence current and module current, this paper provides a new scheme including fault starting element, fault phase selection element, directional element and main criterion. this scheme can bear high impedance and is immune to system surge and frequency warp, which gets over the shortcoming of the lack of sensitivity

    由於現有的保護方案無法快速有效切除此類故障,本文在詳細分析了單相高故障的穩態和暫態特性的基礎上,從小波分析原理出發,利用小波變換檢測突變信號的原理,以零序流、模流等為研究對象,結合方向高頻保護的原理,設了一套包含啟動元件、選相元件、方向元件、主保護的保護新方案。
  14. Have studied generator ground model mostly used in detail for middle and big domestic generator units. calculates and deduces fault current as grounding of single phase and third harmonic fault protection schemes. first time contributes overall knowledge about generator neutral grounding of distribution transformer with secondary resistor, in which considered inductance of the transformer to people

    針對大中型發機的兩種主要方式進行了分析,進行了故障流、三次諧波保護的算推導,首次在變高方式有關公式推導中變感抗,從而使人們對變高認識更為全面。
  15. It utilizes zero impedance branch characteristic, combining structure - transform and structure - static short - circuit current calculation method to calculate the short - circuit current directly through the electrical equipment when short - circuit fault takes place at the two sides of the electrical equipment, and settles the problems that the traditional method cannot directly figure out the short - circuit current

    該方法利用零抗支路特點,結合定結構和變結構短路算方法,能夠直求出在氣設備兩側分別發生短路時,通過氣設備(如斷路器)的短路流,從而合理解決了傳統的故障分析方法不能直求出流過設備的短路流的問題。
  16. By analyzing the refraction 、 reflection process of fault transient current traveling wave of high voltage and characteristics of refraction 、 reflection coefficient systematically, a new fault location method of single ended traveling wave is presented. it can not only identify the reflection wave for fault location efficiently, but also not be affected by the structure and length of line. fault earthed resistance 、 fault type 、 system impedance and can locate fault in adjacent areas accurately

    論文深入分析了高壓線路故障暫態流行波的波折、反射過程以及折、反射系數的特點,提出了新的單端行波故障測距方法,它不僅能夠有效識別出測距所用的反射波,而且幾乎不受線路結構、長短、故障、故障類型、系統抗的影響,在近區仍可以準確進行測距;同時模擬波器的特徵,設了低通數字濾波器,對通過了低通數字濾波器的暫態故障流行波再次進行小波分析,並利用本文提出的單端行波故障測距方法進行故障定位,結論是所提出的測距方法在實際應用中仍是有效的。
  17. This paper is based on the pingpong bridge field ground protection, it presents one point to ground protection scheme which include the self - checking method of switches. the two point to ground protection scheme presents self - adapting fault location warp criterion after evaluating the effect on the calculation of fault location made by the change of transient resistance in the process of bridge switch. in order to make up the shortcoming of location warp criterion, this paper presents a comprehensive scheme into which integrate the second harmonic criterion

    本文針對乒乓式保護,結合開關自檢方法提出了完整的一點保護方案:在兩點保護方案中估算了開關切換過程中過渡變化對點位置算的影響,提出了故障位置偏差式兩點的自適應判據,為了彌補該判據的缺陷,提出了結合二次諧波輔助判據的綜合方案。
  18. In this paper, the research was made to solute these problems. the peterson coil compensation system has been designed which can measure capacitor current and damp degree ; a fault selection method of distribution network which was put forward that based on ftu

    本課題就這兩方面的問題進行了深入研究,設了一種消弧線圈自動補償裝置,該裝置可測量系統對流和尼率,具有響應快、準確性高的優點;同時提出了一種基於ftu的配選線方法。
  19. The paper studies the method of grounding resistance measurement and the new technology of decreasing the grounding resistance. the study includes the method and theory of resistance measurement with short electrode wire, the using and design method of kongfu grounding equipment

    本論文從的測量方法和降低措施兩個方面,深入探討了短距測量的原理、方法,以及新型空腹式裝置的使用和設方法。