接地電阻試驗 的英文怎麼說
中文拼音 [jiēdediànzǔshìyàn]
接地電阻試驗
英文
grounding resistance test- 接 : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 阻 : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
- 試 : 名詞(古代占卜用的器具) astrolabe
- 驗 : 動詞1. (察看; 查考) examine; check; test 2. (產生預期的效果) prove effective; produce the expected result
- 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
- 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
- 試驗 : trial; experiment; test
-
Energy consume, electric strength, insulation resistance, ground conductivity, leakage current, microwave leakage, power input, normal temperature, humidity treatment, glow wire, horizontal flame, vertical flame, tracking, ball pressure, rainproof, water splash, dustproof, salt fog, endurance, motor load test, cord flexing, cord pulling, pull & torque test, lamp replacement, construction check etc
能耗、電氣強度、絕緣電阻、接地連續性、泄漏電流、微波泄漏、功率、溫升、濕熱試驗、灼熱絲、水平燃燒、垂直燃燒、漏電起痕、球壓試驗、防雨淋、防濺水、粉塵、鹽霧、耐久性(壽命)試驗、電機負載試驗、電源線彎折、電源線提拉、拉扭力測試、燈頭互換性、安全結構檢查等。Electrical safety in low voltage distribution systems up to 1000 v a. c. and 1500 v d. c. - equipment for testing, measuring or monitoring of protective measures - part 4 : resistance of earth connection and equipotential bonding
1000v交流和1500v直流的低壓分配系統的電氣安全.防護測量的試驗測量和監測設備.第4部分:地面連接和等電位連接的電阻The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。Check the connection of control circuit shall be in accordance with drawings, the continuity of each circuit, and the insulation resistance against earth
按電路圖檢查控制迴路接線正確,各迴路連續性試驗正確,對地絕緣電阻符合要求。Electrical safety in low voltage distribution systems up to 1 kv a. c. and 1, 5 kv d. c. equipment for testing, measuring or monitoring of protective measures. part 4 : resistance of earth connection and equipotential bonding
最高可達1 kv交流電和1 . 5 kv直流電的低壓配電系統中的電氣安全性.試驗測量或保護測量監測用設備.第4部分:接地和等電位連接電阻Electrical safety in low voltage distribution systems up to 1 kv a. c. and 1, 5 kv d. c. equipment for testing, measuring or monitoring of protective measures. part 5 : resistance to earth
最高可達1 kv交流電和1 . 5 kv直流電的低壓配電系統中的電氣安全性.試驗測量或保護測量監測用設備.第5部分:接地電阻618 method of ground connection resistance measurement is proposed. the effect of some cutting down resistance methods based on theory and practice are researched, large quantities of experiments that affect ground connection resistance have been completed, authentic and reliable data are obtained, conclusion of cutting down the ground connection system resistance of aerospace experiments are drawn. power distribution mode in measurement factory building is explored
就接地電阻測量方法,提出了0 . 618法;對降低接地電阻方法,從理論和實踐兩方面研究幾種降阻方法的效果,並就接地電阻測量和接地電阻阻值的各種影響因素開展了大量實驗,獲得真實可靠數據,在此基礎上開展了進一步研究,為降低航天試驗用接地系統的接地電阻提供了有益的工程實踐經驗和結論。Recurring to rnathematic figure and examples and aiming at such questions as unbalanced current and induced voltage and high frequency interference, this paper has not only researched anti - jamming ability and measuring process of both three - electrode method and four - electrode method which are combined with reverse phase method, but also summarized actual measuring experiences
通過數學推導和實例,圍繞消除地網不平衡電流、電壓極電流極引線問互感電壓、高頻干擾等問題,分析了三極法、四極法結合倒相法測量接地電阻的抗干擾能力和測量過程,並總結了實際測試經驗。分享友人