故障安全電路 的英文怎麼說
中文拼音 [gùzhàngānquándiànlù]
故障安全電路
英文
fault secure circuit- 故 : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
- 障 : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
- 全 : Ⅰ形容詞1 (完備; 齊全) complete 2 (整個) whole; entire; full; total Ⅱ副詞(完全; 都) entirely...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 路 : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
- 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
- 電路 : [訊] circuit (ckt); electric circuit; electrocircuit電路板 circuit board; 電路保持 guard of a c...
-
In order to apply esd to practical engineering, the author develops computer - aided events sequence diagram system ( caesds ). taking the power failure of spaceship cooling circuit drove pump as an example, this thesis uses the improved esd method and the esd model constructed by caesds, drawing a conclusion that the improved method and caesds is valid in manned spaceflight risk assessment
並以飛船冷卻迴路驅動泵電源故障為例,綜合運用改進的esd方法,利用caesds對其建立esd模型,最後分析得到結論,說明了改進的方法和caesds在載人航天安全性風險評估中的有效性。Railway fixed equipment. rules for the application for safety equipment in circuit diagrams for failsafe systems
鐵路固定設備.故障安全系統電路圖中安全設備的應用規則The two - point to earth short fault may cause short currents whic h can lead to serious accident. so it is necessary to monitor the state of field windings of turbo - generator and detect the kind of fault and predict its inclination. thus the security level of power system will be improved
由於發電機轉子兩點接地故障時會產生較大的短路電流,導致惡性事故的發生,因此對發電機轉子繞組進行狀態監測,判斷短路故障的形式和趨勢是十分必要,有助於提高系統安全運行水平。Answer : be on duty the task of perambulatory job is the surveillance, examination, moving state that safeguard and records power supply system, discover the unusual situation of equipment and circuitry in time, handle electric breakdown and accident correctly, make sure reliable safety runs power supply system
答:值班巡視工作的任務是監視、檢查、維護和記錄供電系統的運行狀況,及時發現設備和線路的異常情況,正確處理電氣故障和事故,保證供電系統可靠安全運行。Fault location techniques are used to pinpoint location of the fault on a tra - nsmission line. transmission line faults must be located accurately to allow maintena - nce crew to arrive at the scene and repair the faulted section as soon as possible, which can relief the burdens of patrol personnel and reduce the revenue losses due to power outage. the accurate fault location alogrithms play an important role in power system safety, economy and reliability. in this paper, diversified fault location algorithms are summarized. according to the principles of algorithms, they can be classified into two categories : impedence based algorithm and traveling wave based algorithm. based on the analysis and comparission of each algorithm, the corresponding merits and app - lication limitations are presented
精確的故障定位為現場巡線工作人員及時提供準確、可靠的信息,減輕人工巡線的負擔,同時加快線路的恢復供電,減少因停電造成的綜合經濟損失,為提高電力系統運行的安全性、經濟性和可靠性發揮重要的作用。本文總結了現有的各種測距方法,根據測距的原理將其分為阻抗法和行波法兩大類,對各種演算法的優缺點及適用范圍進行了分析,在此基礎上提出了一種組合的測距方案,並對演算法進行了模擬分析。The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance
爭議點主要是在10kv電網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點接地方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網接地電容電流變化、中性點電阻取值大小、接地點接地電阻值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小電阻接地方式下電網的過電壓水平和接地點短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。In the term of restoration reconfiguration, it is necessary to assure that all lines current and nodes voltage are in the limits of safety
故障恢復過程中保證所有的線路電流或節點電壓在安全范圍限度內。The others is fire faul prevenion scheme of double diminuive computer plus disk mp which is a magnetic tape set in the network for back up, in order to preveni data losing because of mainfraxne systcm is wrong, which ensures data safe
其它各供電單位採用雙小型機加磁盤陣列的容錯方案,為保證數據的安全,在網路上設置一臺磁帶庫作為數據備份,防止主機系統故障引起的數據丟失。The product facilitates extensive safety functions including : self diagnostic circuit ( temperature sensor malfunction, heater disconnection, automatic overheat preventive device, ssr short circuit ), over heat preventive device, over current electric leakage breaker, and key lock function
故障自我診斷(溫度傳感器異常、加熱器斷線、自動溫度過升防止功能、 ssr短路) ,過升防止器、過電流漏電保安開關、鍵盤鎖定等安全功能充實。This paper presents two new electric system devices, a grounding and short - circuit fault indicator and an intelligent hybrid dc contactor. the fault indicator may be used in mid to high voltage power system
其中,短路與接地故障顯示裝置可用於檢測中、高壓電力系統短路或接地故障,該裝置具有強弱電隔離、安全性好、安裝方便、能耗低、成本低的特點。The protection constitution of connecting the ground can cut off the troubling electric circuit quickly and effectively before causing the personal casualty, a fire trouble and circuit to damage, and thus protecting the personal safety and reducing the occurrence of the trouble
摘要接地故障保護設置能在故障線路引起人身傷亡、火災事故以及線路損壞之前,迅速有效地切斷故障電路,從而保護人身安全,減少事故的發生。Random failures of generator, transformer, transmission line, protection system and topology of both power station and power network are constructed
根據元件故障的概率分佈,建立靜態安全分析中發電機、變壓器、輸電線路、保護系統的隨機故障模型。The automatic electricity - heat pot adopts the unique mechanical and electrical design which simplifies the operation process and saves energy and time ; it is a complete monitor and control system which detects the following breakdowns : overheat, overpressure, the damage of components, water shortage, short circuit, electricity leakage, misoperation
該炊事鍋在機械和電控上採用了獨特設計,大大簡化了操作過程,省時省力;實現了全方位、多層次的安全監測和控制體系,形成了一個超溫、超壓、元件損壞、缺水干燒、短路漏電、異常操作等故障報警與故障自動處理的完整安全監控體系。According to the rule of mine safety regulations, an intrinsically safe pilot circuit with perfect performance for underground motor intelligent protective systems is put forward, which can effectively avoid the phenomenon of self - starting that is caused by the earthing of control lines before starting motors, at the same time, can reliably cut off the switches to ensure the safety of underground production under operation condition no matter what the faults of short circuit, open circuit and earthing in the control circuits happened
根據煤礦安全規程規定設計了性能完善的本質安全型先導電路,起動前它能有效地防止因控制線接地造成自起動現象的發生,而且在運行中無論控制線發生短路、斷線還是接地故障,它均能可靠跳閘,確保生產的安全,該先導電路的性能指標達到了國內領先水平。Auto power cut - off when standby for 30 minutes or temperature test system failure. it achieves energy save, safety and prolongs life of heater
當30分鐘閑置,或測溫系統出現故障,如焊咀溫度低於警誡線,發熱芯或線路板發生故障時,自動切斷電源,具安全,省電及延長芯頭壽命的優勢。The iced insulators flashover is one of the main faults of the ehv transmission lines in icing regions. icing is especial form of pollution
對覆冰地區的超高壓線路,絕緣子覆冰引起的閃絡已經成為最主要的故障之一,對電力系統的安全運行造成了極大的威脅。Since the 155 mbs connections of coaxial cables or tail optical fibers are most vulnerable to faults in channels and are not able to provide sdh self - healing protection, we should pay special attention to its safety
由於155mbits的同軸電纜或光尾纖連接,是通路中的故障多發點,也是不能提供sdh自愈環保護的地方。因此,要特別注意其安全問題。For real - time monitoring the each work status of fuel cell, on time discovering every kind of equipment failure of, fuel cell of condition monitoring and fault diagnosis system adopts the usb bus system to set up the hardware platform, regarding neural network theory as foundation, creates fault diagnosis model and algorithm, and joining together both of the advantage, guarantees the safe and dependable running of fuel cell system
為了能夠實時監測燃料電池的各個工作狀態、及時發現各種可能出現的設備故障,燃料電池狀態監測與故障診斷系統採用usb總線系統搭建硬體平臺,以神經網路理論為基礎,建立故障診斷模型與演算法,把兩者的優點充分結合,保證了燃料電池系統安全可靠的運行。Based on the investigation of analysis methods for the overvoltage striking on rotating electric machines and its research status at home and abroad, the safety forecast theory and the analysis method for the switching overvoltage of large power stations are firstly presented based on the field - circuit analysis, and the transient field distribution and the insulation condition in the stator winding insulator stricken by the switching overvoltage in large power stations are studied and analyzed on line
本文在分析和總結國內外關于旋轉電機過電壓分析方法及其研究現狀的基礎上,首次提出了基於場路結合的廠站操作過電壓安全預測理論和分析方法。本文研究了大型電站中的操作過電壓沖擊波在發電機定子繞組絕緣介質中暫態電場的實時分佈狀態,在線分析發電機的絕緣工作狀況,搜索發電機內部可能突發絕緣事故的區域,預測發電機內部可能發生絕緣事故的故障點,並重點研究了大型發電機絕緣安全在線預測分析方法和建立了大型發電機絕緣安全評估模型。Through real - time detecting and controlling on the facilities and environment in the central control room, for instance, the setup of the remote control on the air conditioner, the remote control on the real - time recording from 6 - route video cameras and the remote control on the permission of the integrated pan and tilts, the personnel in out access through three main entrances and the informing management for failure identification via phonetic system, the system ensures the safety and effective management in the central control room
通過該系統對機房內的設備及環境進行實時監測與控制,例如:對機房內的空調進行遠程開關機設置通過六路視頻實時錄像,同時允許對一體化球機進行遠程控制對3道重要門進行人員出入控制及出入記錄將重要事故及故障通過電話語音通知機房管理人員,從而確保機房整體系統的安全性,提高機房管理的效率。分享友人