散熱損失 的英文怎麼說

中文拼音 [sǎnsǔnshī]
散熱損失 英文
dissipation heat loss
  • : 散動詞1. (由聚集而分離) break up; disperse 2. (散布) distribute; disseminate; give out 3. (排除) dispel; let out
  • : Ⅰ動詞1 (減少) decrease; lose 2 (損害) harm; damage 3 [方言] (用尖刻的話挖苦人) speak sarcas...
  • 散熱 : heat radiation; radiating; thermolysis; abstract heat; heat dissipation; cooling散熱風門 throttle...
  • 損失 : 1. (失去) lose 2. (失去的東西) loss; wastage
  1. Aimed at the high temperature at furnace roof and wall, great lost of body heat radiation, poor leading heating ability and long soaking time, the compound ceramic fiber coating is used to hold temperature of furnace roof and wall, make the heating loss dropped, shorten soaking time, improve heating ability and reduce evergy consumption

    摘要針對環形爐爐頂爐墻表面溫度高、爐體散熱損失大、導致加能力低、待溫時間偏長的問題,選用了復合陶瓷纖維保溫塗料,使爐體散熱損失減少,待溫時間縮短,加能力提高,且能耗降低。
  2. This paper introduces that the diffuse heat heating furnace is reduced the consumption of fuel is debased and the preferable effect is got, using the multicrystal mullite fibrous stickup lump to heat preservation in heating furnace wall

    摘要採用多晶莫來石纖維貼面塊對加爐爐內壁保溫,減少了爐體的散熱損失,降低了爐子燃耗,取得了較好的效果。
  3. Energy consumption of heating rooms will increase when air exchange rate become large. because the mechanisms of heating methods used currently, such as radiator heating, ceiling heating and warm - air heating, are different from each - other, the indoor thermal environment is not the same when each one of them employed for room heating. for enhancing energy efficiency of heating rooms, indoor thermal comfort and energy saving effects should be investigated when natural ventilation is used to make a good air quality indoors

    房間換氣次數的增加勢必導致供暖房間能耗加大,頂棚輻射、器和風等三種採暖方式由於供暖機理不同,形成的室內環境特徵不同,通風換氣時產生的通風也有所區別,為了提高大換氣量房間的供暖節能效果,必須對不同供暖方式在大換氣量情況下的舒適性與節能效應進行研究。
  4. Via the analysis of heat balance computation model and the computation of online heat balance for industrial coal boiler, this dissertation researched overall input heat, efficient utilized quantity of heat, heat losing of discharge flue gas, heat losing of chemistry and mechanism incomplete combustion, heat losing of dispelling heat of boiler, heat efficiency, air superfluous coefficient, wind speed, wind quantity, computation of primary air circle cutting and whose influence on boiler combustion efficiency

    本文通過對工業煤粉鍋爐平衡計算模型的分析,利用在線平衡計算,研究了總輸入、有效利用量、排煙、化學不完全燃燒、機械不完全燃燒、鍋爐效率、空氣過剩系數、風速、風量及一次風切圓計算以及這些因素對鍋爐燃燒效率的影響。
  5. However carefully boiler casings and steam pipes are sealed, some heat escapes and is lost

    不管鍋爐與蒸汽管封閉的多麼嚴密,還是有一部分耗掉。
  6. Abstract : the causes for low efficiency of the heater in no. 2 crude unit of jpc refinery are described and analyzed including water leaking of steam soot blower, dew point corrosion caused by steam, soot deposits in convection chamber owning to poor soot blowing, high flue gas temperature, no heat recovery of flue gas, and poor performance of insulation lining, etc. by using sonic soot removing system, flue gas recovery system, spray coating of fiber and rock wool, as well as adjustment of flow scheme accordingly in the technical revamping. the dew point corrosion is completely eliminated, the insulation performance is improved, the heat loss is reduced by 1. 25 %, the flue gas temperature is reduced to about 170, and the heater efficiency is increased from 83 % to more than 90 %

    文摘:分析了金陵石油化工公司煉油廠二套常減壓裝置加爐存在的因蒸汽吹灰器漏水,蒸汽引起露點腐蝕及吹灰效果差造成對流室積灰,排煙溫度高,煙氣量未回收利用以及爐子保溫襯里效果差等問題,提出採用聲波除灰系統、煙氣回收系統、纖維噴塗和巖棉噴塗及相應的流程調整等改造措施.測定結果表明,本次技術改造解決了因蒸汽吹灰器漏水所造成的露點腐蝕問題,提高了保溫效果,減少散熱損失1 . 25 % ,排煙溫度降至170左右,裝置的爐效率由83 %左右提高到90 %以上
  7. The causes for low efficiency of the heater in no. 2 crude unit of jpc refinery are described and analyzed including water leaking of steam soot blower, dew point corrosion caused by steam, soot deposits in convection chamber owning to poor soot blowing, high flue gas temperature, no heat recovery of flue gas, and poor performance of insulation lining, etc. by using sonic soot removing system, flue gas recovery system, spray coating of fiber and rock wool, as well as adjustment of flow scheme accordingly in the technical revamping. the dew point corrosion is completely eliminated, the insulation performance is improved, the heat loss is reduced by 1. 25 %, the flue gas temperature is reduced to about 170, and the heater efficiency is increased from 83 % to more than 90 %

    分析了金陵石油化工公司煉油廠二套常減壓裝置加爐存在的因蒸汽吹灰器漏水,蒸汽引起露點腐蝕及吹灰效果差造成對流室積灰,排煙溫度高,煙氣量未回收利用以及爐子保溫襯里效果差等問題,提出採用聲波除灰系統、煙氣回收系統、纖維噴塗和巖棉噴塗及相應的流程調整等改造措施.測定結果表明,本次技術改造解決了因蒸汽吹灰器漏水所造成的露點腐蝕問題,提高了保溫效果,減少散熱損失1 . 25 % ,排煙溫度降至170左右,裝置的爐效率由83 %左右提高到90 %以上
  8. Test method for heat release, flame spread and mass loss testing of insulating materials contained in electrical or optical fiber cables when burning in a vertical cable tray configuration

    電纜或光纜絕緣材料在立式電纜槽裝置中燃燒時火焰傳播和質量測試的試驗方法
  9. Standard test method for heat release, flame spread, smoke obscuration, and mass loss testing of insulating materials contained in electrical or optical fiber cables when burning in a vertical cable tray configuration

    電纜或光纜絕緣材料在立式電纜槽裝置中燃燒時火焰傳播煙的昏暗度和質量測試的標準試驗方法
  10. Methods measuring and evaluating heat loss and thermal insulation efficiency for thermal insulation construction of heating pipeline

    管道保溫結構散熱損失測試與保溫效果評定
  11. Methodds measuring and evaluating heat loss and thermal insulation efficiency for thermal insulation construction of heating pipeline

    管道保溫結構散熱損失測試與保溫效果評定方法
  12. The phase structure of different cu - fe thin films were studied by using grazing incidence x - ray analysis ( gixa ). the texture and residual stress of different cu - fe thin films were measured by scan of x - ray diffraction ( xrd ) and 2 scan with different. the thicknesses of different thin films were characterized by means of small angle x - ray scattering ( saxs ) technique. by using atomic force microscope ( afm ) measured surface roughness of thin films. the component of different thin film was characterized by energy disperse spectrum ( eds ) and x - ray fluorescence ( xrf ). the magnetic properties of cu - fe thin films were measured by means of vibrating sample magnetometer ( vsm ). in addition, the giant magnetoresistance ( gmr ) effects of different films were also measured. the original resistance of the film fabricated by a direction - current magnetron sputtering system is directly affected by bias voltage

    利用掠入射x射線分析( gixa )技術對不同cu - fe薄膜的相結構進行了研究;利用xrd掃描及不同角度的2掃描對薄膜進行了結晶織構及殘余應力分析;運用小角x射線射( saxs )技術測量了薄膜的厚度;採用原子力顯微鏡( afm )觀察了薄膜的表面形貌;運用能量譜( eds )及x射線熒光光譜( xrf )對薄膜進行了成分標定;使用振動樣品磁強計測量了不同cu - fe過飽和固溶體薄膜的磁性能;最後利用自製的磁阻性能測試設備測量了真空磁場處理前後不同薄膜的巨磁阻值。
  13. Measuring heat loss for equipments and pipes

    設備及管道散熱損失的測定
  14. The allowable maximum heat loss prescribed in the national standard is taken as a basic reference by many other related standards

    摘要國家標準《設備及管道保溫技術通則》中規定的允許最大散熱損失值被多個相關標準引用。
  15. Points out the irrationality of the prescription in the standard, and analyses and studies the correlative regulations in the russian standards

    指出該通則中對允許最大散熱損失值的規定存在不妥之處,並分析和研究了俄羅斯相關國家標準中的有關規定。
  16. High thermal efficiency, the principle of heat trans - fer of the cylinder dryer is heat conduction whose conducting direction keeps identical whole opera - toion circle

    因滾筒乾燥機傳機理屬傳導,傳方向在整個操作周期中保持一致,除蓋輻射外,其餘量。
分享友人