There is not composite enhancing effect to shear resistance of reinforced concrete beams between steel fiber and stirrups
鋼纖維與箍筋之間在提高鋼筋混凝土梁斜截面承載力方面不存在「藕合增強效應」 。Then the coupling beams with new reinforcement layout were made an inquiry into, and the improvement on the seismic behavior by coupling beams diagonally reinforced with a few rows in end regions was found out at last, based on the observations of the experimental phenomena and the analysis of the measurement result, and by the comparison of seismic behavior by making use of hysteretic response, ductility and energy dissipation behavior, a conclusion is presented : the code for design and construction of reinforced concrete high - rise structures ( the draft asked for advise hi 2000 ) ca n ' t ensure that the coupling beams have fairly good seismic ductility ; the result of improvement of the seismic ductility of the coupling beams by the increase hi stirrups besides the strengthen of longitudinal detailing reinforcement was n ' t obvious ; the coupling beams diagonally reinforced with a few rows in end regions have fairly good mechanisms, and the ductility and the behavior of energy dissipation are better than conventionally reinforced concrete coupling beams, so it is suitable to te tised in short coupling beams
本文通過對三根小跨高比(均為l h = 1 . 0 )剪力墻洞口連系梁在低周反復荷載作用下的試驗,了解了嚴格按《鋼筋混凝土高層建築結構設計與施工規程》 ( 2000年徵求意見稿)設計的連梁具有的抗震性能,研究了採取增大連梁配箍量同時加強縱向構造筋的方案對抗震性能的影響,並進一步對新的配筋形式的連梁進行了探討,了解了在連梁梁端配置多排交叉斜筋方案對連梁抗震性能的改善。通過對試驗現象的觀察和量測結果的分析,利用荷載?位移滯回曲線、延性和耗能性能等指標對各個試件的抗震性能進行了比較,最後得出結論: 《鋼筋混凝土高層建築結構設計與施工規程》 ( 2000年徵求意見稿)不能保證小跨高比連梁具有較好的抗震延性:通過增大連梁配箍量同時加強縱向構造筋的方案對改善連梁的抗震延性的效果不太明顯;梁端配置多排交叉斜筋的連梁具有相對較好的受力性能,其延性和耗能性能等各項性能指標均優于普通配筋連梁,宜在深連梁中採用。Inclined stirrups are not effective in beams resisting shear reversals, such as seismic loads, because the reversals will cause cracking parallel to the inclined reinforcement, rendering it ineffective
也就是說,哪怕縱向鋼筋不彎起(保證支座叢筋在上下都足以抵抗地震力產生的彎矩) ,箍筋用斜的,也不行!2. based on the test results published over the word of steel fiber reinforced concrete beams without web reinforcements and with stirrups, the effects of steel fiber to shear resistance and the relationship of steel fiber to stirrups are analyzed, the improvements of steel fiber to failure states of reinforced concrete beams without web reinforcements are discussed. it is proposed that the formula of shear resistance of steel fiber reinforced concrete beams based on the model of the current design and construction spectification of steel fiber reinforced concrete structures ( cecs38 : 92 ), used of the uniaxial tensile strength of steel fiber reinforced concrete, and combined with different formulas specified in current design codes of concrete structures issued by different trades
根據收集到的國內外對鋼筋鋼纖維混凝土無腹筋梁和鋼筋鋼纖維混凝土有腹筋梁的斜截面受力性能試驗研究成果,對鋼纖維在增強鋼筋混凝土無腹筋梁和有腹筋梁斜截面承載力方面的作用及其在箍筋抗剪承載力的關系進行了總結分析,對鋼纖維改善鋼筋混凝土梁破壞形態方面的作用進行了分析討論,提出了採用鋼纖維混凝土軸心抗拉強度指標,基於現行cecs38 : 92 《鋼纖維混凝土結構設計與施工規程》計算模式、能夠與目前國內各行業現行混凝土結構設計規范中不同的鋼筋混凝土梁受剪承載力設計方法配套使用的鋼筋鋼纖維混凝土梁受剪承載力設計方法。分享友人