有效蒸散 的英文怎麼說

中文拼音 [yǒuxiàozhēngsǎn]
有效蒸散 英文
actual evapotranspiration
  • : 有副詞[書面語] (表示整數之外再加零數): 30 有 5 thirty-five; 10 有 5年 fifteen years
  • : Ⅰ名詞(效果; 功用) effect; efficiency; result Ⅱ動詞1 (仿效) imitate; follow the example of 2 ...
  • : Ⅰ動詞1. (蒸發) evaporate2. (利用水蒸氣的熱力使食物熟或熱) steam Ⅱ名詞[中醫] (將藥物隔水蒸熟) steaming
  • : 散動詞1. (由聚集而分離) break up; disperse 2. (散布) distribute; disseminate; give out 3. (排除) dispel; let out
  • 有效 : effective; valid; efficacious
  1. Using domestic strained integrated resistor as weighing sensor, at89c52 single chip as control unit, combined with arithmetical magnification, analogtodigital conversion ( a / d ), real time clock, liquid crystal display ( lcd ), and series communication interface, a minitype automatic weighing lysimeter is developed. that made measurement of evapotranspiration become conveniently and effectively in studying on water use of crops

    為了方便、地測定植物的,為水分利用研究提供價廉物美、簡單易用的儀器,本研究利用國產的集成電阻應變式稱重傳感器,採用at89c52單片機作為控制單元,結合運算放大、模數轉換、實時時鐘、液晶顯示、數據存儲、串列通信等外圍介面電路,研製了小型自動稱重式儀。
  2. The non - irrigation plantation in moving sand dune and sandy girder areas should adopt some biological and engineering measures such as runoff - collecting to improve effects of rainfall, reduce losses by evaporation and depth leaking, and improving circulation and transformation of water in sandy plantation ecology system by reasonable allocation

    在無灌溉條件的流動沙丘和沙梁地,通過徑流匯集利用,充分實現降雨的化,利用各種生物和工程措施來減少植被系統的無損失和深層滲漏,通過合理配置提高水資源的循環與轉化是沙區發展免灌植被的主要途徑。
  3. B2o3 could barrier the diffusion of o2 and na2so4 steam into interphase downwards of 1273k of volatilization temperature of b2o3

    氧化硼在其揮發溫度( 1273k )以下能夠阻擋氧及部分硫酸鈉汽的進一步擴,從而保護了纖維。
  4. The main products includes various steam and electric heating reaction vessel, conduction oil, outer coil reaction vessel, polyester and resin completed equipments, vacuum reducing concentration tank, methanol and ethanol recovery tower, various corrugated stuffing, high effective membrane evaporator, new - type centrifugal drag membrane evaporator, vacuum rake dryer, condensing drum cut - off machine, shell - and - tube condenser,

    本廠主要產品各類氣電加熱反應鍋,導熱油外盤管反應鍋,聚脂樹脂全套設備,真空減壓濃縮罐,甲醇乙醇回收塔,各類波紋填料,高薄膜發器,新型離心刮板式薄膜發器,真空耙式乾燥機,冷凝滾筒切片機,列管式冷凝器,螺旋板式換熱器,外循環發器,鋁制槽車貯罐,乳化設備,高速剪切分機,種子罐,發酵罐,多功能提取罐,並承接各類非標設備。
  5. On the base of the palmer drought severity model of america and the modificated palmer drought severity model ( 1986 ), we further modificate the palmer drought severity model in the following aspects ; ? 4 stations were chosen to develope the model and adjust the weighting factor ; ? he potential evapotranspiration for an each month was computed by the penman - monteith equation commended by fao ; ( 3 ) the getting of available water capacity of the soil ( awc ) in each station was based on the data of awc that we can find and the characteristic of soil in each station

    在美國帕默爾旱度模式和我國1985年修正的帕默爾旱度模式的基礎上,針對其中存在的問題,從建模選用較多站點、可能計算採用彭曼?蒙特斯公式和土壤田間持水量進一步準確劃分等三個方面進一步修正了帕默爾旱度模式。
  6. Another important conclusion the present study reached is that the controlling of diffusion coefficient do and evaporation coefficient f0 is efficient for the deduction of the possibility of the " popcorn " delaminations, in specific with controlling evaporation coefficient

    對裂尖能量釋放率的影響較大,因此,控制擴系數do和發系數f 。能地降低電子元件發生「爆米花」式脫層斷裂的可能性,尤其是控制發系數f 。
  7. The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴規律進行了試驗,得出分離式熱管一最佳充液率,其值為45 %左右;凝結換熱系數隨著汽壓力的增加略降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制
  8. Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    文摘:建立了空氣冷卻實驗臺,熱管的加熱方式為電加熱,工質為餾水.在1 1模型上對分離式熱管管內凝結換熱特性、不凝性氣體對凝結換熱的影響及不凝性氣體的擴規律進行了試驗,得出分離式熱管一最佳充液率,其值為45 %左右;凝結換熱系數隨著汽壓力的增加略降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對分離式熱管的凝結換熱僅影響冷凝段下部較小部分,通過排氣閥排出不凝性氣體可地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性氣體對分離式熱管冷凝段的影響減少.這些結論可用於分離式熱管換熱器的工程設計和控制
分享友人