校準精度 的英文怎麼說

中文拼音 [jiàozhǔnjīng]
校準精度 英文
accuracy in calibration
  • : 校名詞1. (學校) school 2. (校官) field officer3. (姓氏) a surname
  • : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
  • : Ⅰ形容詞1 (經過提煉或挑選的) refined; picked; choice 2 (完美;最好) perfect; excellent 3 (細)...
  • : 度動詞[書面語] (推測; 估計) surmise; estimate
  • 精度 : precision; accuracy; degree of accuracy; precision accuracy; trueness
  1. During the evaluation method for the precision of missile aiming on the sea, setting up test structure system, confirming demand coordinate, putting up installation and calibration to test frame of missile silo, in the course of navigating, it was analyzed and calculated the direction error that brought by the incorrectness of the position of longitude and latitude

    在海上瞄鑒定方法中,建立了試驗構建體系,確定了必要的坐標系,對彈筒試驗支架進行了裝調、正和實際標定。對艇在航行過程中,由於艇的經、緯確而帶來的定位誤差的影響進行了分析與討論。
  2. Based on the verification regulation of prt, this paper studies the temperature characteristics of prt, suggests a method of improving the accuracy of measurement and supplies the uncertainty of calibration point

    摘要分析了檢定規程對鉑電阻溫計的要求,通過研究鉑電阻溫計的測溫特性,提出了提高鉑電阻溫計測量的方法,並給出了在溫點的測量不確定
  3. On the part of the design of nine - component thrust vector stand, an automatic hydraulic pressure original position calibration system, a scheme of original position calibration, and the great rigidity universal flexible combinatorial underprop are designed. by using the scheme of “ universal flexible combinatorial underprop plus software digital filter ”, the inherent frequency of test stand is improved, and the problem of test stand libration is solved. then, the resolving method of the disturbance between underprops of the moveable frame is proposed, and the disturbance revise equation is deduced

    在推力矢量試車臺設計方面,設計了自動液壓原位系統、原位方案以及大剛萬向柔性組合支撐;採用「萬向柔性組合支撐+軟體數字濾波」的方案,提高了試車臺動架的固有頻率,解決了試車臺動架的振動問題;提出了動架約束互擾問題的解決方法,推導了互擾修正方程;研究了九分力推力矢量測量誤差分析方法,並計算了推力矢量測量
  4. The paper consists of two parts, the first subject is the research on high precision charge calibrator, the other one is the measurement and application of the dynamic testing asics

    本文內容分為兩篇,第一篇題目是高電荷儀的研究,第二篇題目是動態測試專用集成電路的檢測與應用。
  5. Using mass flux controller ( mfc ), gas regulation system achieved accurate mix of two kinds of gases, steel bottle gas ( some compressed gas ) and zero air ( pure air ). for the sake of data transmission between dynamic air regulator and other equipments in the monitoring air quality system, normal digital interface ( rs - 232c ) make correlative role of communication interface so that automatic survey could be achieved

    本儀器採用國際先進的自動控制配氣原理,採用密質量流量控制器( mfc )來控制鋼瓶氣(某種壓縮氣體)與零空氣(純凈無污染的空氣)的混合比來得到確濃氣體,以便於對各種氣體監測儀進行高
  6. As proved by experiments, the present method can effectively restrain the influence of speckle to the laser triangular measurement system and the obtained calibration accuracy is about 0. 05mm within 100mm depth range

    只需對特殊設計的模塊進行一次測量,便可完成對整個測量系統的。該方法能夠有效的抑制激光散斑的影響,具有較高的系統
  7. According to characteristics of the seismic data from the low snr region with complex surface, this paper is started from solving the static correction problem and reasonable eliminating all kinds of disturbance in the seismic data from the low snr region with complex surface. through the whole process of seismic data processing which includes a series of processing methods that are suitable for the low snr region, namely, from the choosing of the floating base - level, the static correction in the field and indoors, the eliminating of all kinds of noise before and after stacking, the velocity analysis with high - resolution, the reasonable techniques of deconvolution before stacking and wavelet processing after stacking, to the method choosing of the high - resolution stacking and the reasonable and accurate offset imaging, a set of the complete and effective flow for processing seismic data from the low snr region with complex surface are finally formed, which can meet the need of explo

    本文針對復雜地表低信噪比地區地震資料的特點,以解決復雜地表低信噪比地區地震資料靜正問題及合理剔除各類干擾為出發點,在整個地震資料處理過程中,從浮動基面的選取、野外及室內靜正、疊前疊后各類噪音的去除、高分析、合理的疊前反褶積及疊后子波處理技術、到選用高的疊加技術及合理確的偏移成像方法等一系列適合於復雜地表低信噪比地區的處理方法,最終形成一套較完整且有效的針對復雜地表低信噪比地區地震資料的處理流程。
  8. In order to enhance the precision, this design proposes that temperature - measuring circuit of platinum resistors and software should be employed to carry on adjustment of measured precision ; it also proposes that the interference of the grid can be reduced by the voltage front feed ; and meanwhile it calls for the application of the photoelectric insulation, the over heating protection and alarm so as to enhance the security performance of the system

    為了提高,本設計還採用了鉑電阻溫測量電路,並利用軟體對測量進行自;通過電壓前饋控制減少電網干擾。此外,設計中還加入了光電隔離措施及過熱自動保護和報警功能,以增強系統的安全性能。
  9. Calibration specification for linear accelerometer used precision centrifuger

    線加速計的密離心機規范
  10. Gps is a planet wireless conductance system which is global and all - weather, gps can offer high precision time orientation information to infinite user, clock precision reachs 10 ? 6 magnitude 。 not only changes traditional time method of quartz crystal clock, but also replaces wireless shortwave and even more lowfrequency signal and tv signal whose overlay range is limited and low precision, offers advantage to geology field task, achieve automatization and high precision of seismic flow observation

    利用gps授時信號全方位、全天候、連續性、實時性和高的特點,以gps信號為基本地時鐘(晶體振蕩時鐘或原子鐘) ,將gps接收機輸出信號的長期穩定和恆溫晶振的短期穩定相結合,應用大規模可編程邏輯器件,設計和實現了由pc104控制的實時在線授時系統。
  11. The accuracy of the calibration is itself important

    校準精度本身很重要。
  12. And the calibrating method being used nowadays can not meet the specific needs, because the operation is complex, and the calibration precision is low

    由於其工作環境特殊,現有的各種密測角方法都不適用。目前採用的標定方法操作復雜,校準精度較低,不能滿足要求。
  13. In chapter 2, the mechanics of distortion of movements for the vibrator, which affect the precision of calibration, are explored in detailed. and the effects of measuring system and automatic control are also researched profoundly

    深入研究了振動臺運動波形失真的機理及對校準精度的影響,同時研究了測量系統、系統穩定性和自動控制技術對校準精度的影響。
  14. The method using square wave excitation presented by the paper is verified by theories and experiments that the method meets the requirement of accuracy, and this method ' s application simplifies manipulations and improve greatly the calibration efficiency

    其中本文提出的方波信號激勵的比較法,理論和實驗證明不僅滿足校準精度要求,而且簡化操作,大大提高了的效率。
  15. In chapter 4, the improvements of automation by developing the high performance vcs controlled by pc are stated, which include the hardware system of vibration measured control instrument ( vmc ), the software system of vcs and the virtual device driver programme ( vxd )

    第四章著重介紹了高性能微機控制系統的開發及對校準精度和自動化程的影響。主要開發了振動裝置測控儀硬體系統、振動測控軟體系統以及vxd虛擬設備驅動程序。
  16. Beam can be seen very easy to make high - precision calibration

    可見光束使高十分簡單易行
  17. Ddsy951 electronic single - phase advace - payment electric energy meter following as meter with a shielded and sealed construction, adops microelectromic technoligy to measure electricity and comes up to standard of gb t17215 - 1998 and gb t18460 - 2001. it collects handles and stores dataset with advanced monolithic processing system. the meter features in good abti - electromagnetism, low power loss, high precision, abstraction - of - electricity prevention, high overload and long service life

    Dtsy951電子式三相預付費液晶電能表下稱電表採用微電子技術計量電能,符合gb t17215 - 1998和gb t18460 - 2001標的電表,採用全屏蔽全封閉結構,用先進的單片機處理系統進行數據的採集處理和保存,具有良好的抗電磁干擾低自耗節電高不需表防竊表高過載長壽命的特點。
  18. Sb2015 - 3 precision decade dc resistance box adopts high voltage glass glaze resistors and special high voltage seal switch. its electric performance is very stable and insulation intension is very high. the resistance value can be adjusted under the condition of ceaselessly opening voltage ( note : the using switch should not be at the point of 0. ) it is easy to operate and suitable to be used to calibrate insulation resistance meter, and suitable to be used as high resistance standard

    3型密十進位直流電阻箱採用高壓玻璃釉電阻器及獨特的高壓密封開關,電性能穩定可靠、絕緣強高、可在不斷開測試電壓的條件下調節電阻值(正在使用的那隻開關不處在「 0 」位置時) 、操作方便,適用於檢定/絕緣電阻表,也可作為高阻標
  19. Sb2015 - 2 precision decade dc resistance box adopts high resistance superfine glass silk and special high voltage seal switch. it electric performance is very stable and insulation intension is very high. the resistance value can be adjusted under the condition of ceaselessly opening voltage ( note : the using switch should not be at the point of 0. ) it is easy to operate and suitable to be used as dc resistance standard to calibrate insulation resistance meter

    2型密十進位直流電阻箱採用高阻玻璃微細絲電阻器及獨特的高壓密封開關,電性能穩定可靠、絕緣強高、可在不斷開測試電壓的條件下調節電阻值(正在使用的那隻開關不處在「 0 」位置時) 、操作方便,適用於檢定/絕緣電阻表,也可作為直流電阻標
  20. To improve interceptor ' s tracking & aiming precision, it is necessary to make qualitative analyses and quantitative measurements about the ao effects related to the interceptor ' s seeker in the high speed real gas, and establish a set of ground simulation / test methods to test the ao effects and its calibration mechanism

    為了提高攔截彈的跟蹤瞄,必須對攔截彈導引頭在高速真實氣體環境下的氣動光學效應進行定性分析和定量測量,並建立能滿足氣動光學效應與正機理研究的地面模擬測試方法。
分享友人