標準量度 的英文怎麼說
中文拼音 [biāozhǔnliángdù]
標準量度
英文
standard measure- 標 : Ⅰ名詞1 [書面語] (樹梢) treetop; the tip of a tree2 (枝節或表面) symptom; outside appearance; ...
- 準 : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
- 量 : 量動1. (度量) measure 2. (估量) estimate; size up
- 度 : 度動詞[書面語] (推測; 估計) surmise; estimate
- 標準 : (衡量事物的準則; 榜樣; 規范) standard; criterion; benchmark; pip; rule; ètalon (衡器); merits
- 量度 : [數學] mensuration; measure; measurement; magnitude量度器 measurer
-
Standard on television : measurement of luminance signal levels
電視標準:亮度信號電平的測量The activatory coal gangue powder ( acgp ), ground cement clinker and natural gypsum are mixed by different ratios to prepare blended cement specimens, and its mortar compressive strength performance, water usage for standard consistency, and flowability of mortar are investigated
摘要將經燃燒等過程進行活化處理的煤矸石細粉與磨至一定比表面積的水泥熟料及天然生石膏混合均勻,製成了活化謀矸石粉摻量比例不同的多組混合水泥,並對其膠砂強度性能、標準稠度用水量、膠砂流動度進行了實驗檢測。Beckmann thermometers are designed to measure small temperature differences. hence the calibration of a beckmann thermometer refers to comparing the true temperature differences obtained from the laboratory s standard thermometers against the observed temperature differences indicated by scale readings of the unit under test
貝克曼溫度計是用於測量微細的溫差,因此本所將其標準溫度計所錄得的真正溫差與接受測試元件的標度讀數所顯示的觀察溫差進行對比,以校正貝克曼溫度計。Standard test method for water
水泥標準稠度用水量凝結時間安定性檢驗方法Results the diagnosis standard of spleen - deficiency syndrome of plc is 34 points ; the sen, spe and acc of the prospective and retrospective examination of it are over 85 %. + lr of them are respectively 9. 6 and 11. 3 ; 34 - 48 points is classified as low grade, 49 - 62 points is classified as medium grade, high grade is 63poiots
結果原發性肝癌脾氣虛證量化診斷標準最低分為34分;量化診斷標準回顧性和前瞻性檢驗的敏感度、特異度、準確度均在85 %以上,陽性似然比分別為9 . 6和11 . 33 ;程度分級標準:輕度34 ~ 48分,中度49 ~ 62分,重度63分。To limit the predicting precision loss in a certain range, author presented a method of bayes modeling and predicting for dynamic errors based on standard value interpolation at intervals during the multi - step prediction after consulting a lot of papers at home and abroad
為將預報精度損失控制在一定的范圍之內,作者在查閱了國內外大量相關文獻之後,提出了基於標準量插入的動態測量誤差的貝葉斯建模預報理論,並根據貝葉斯理論給出了預報值的不確定度。On the base of experiment & study of tile influence of different gypsum on performance of portland - sulphoalminate composite cement system as set time, water requirement of normal consistence, strength, ect, the influence mechanism was discussed
摘要在試驗研究不同石膏品種對硅酸鹽硫鋁酸鹽復合體系水泥凝結時間、標準稠度需水量、強度等性能影響的基礎上,探討了石膏品種對硅酸鹽硫鋁酸鹽復合體系水泥性能的影響機理。Using the inverse model to calculate the distribution of source density, based on gauss smoke plume ' s standard density distribution, environmental capacity of fluoride in the air of northern suburban in xining was found
摘要由高斯煙羽模式推導出的標準濃度分佈推算源強分佈的反演模式方法,計算了西寧市北郊地區環境空氣中氟化物的環境容量。Coordinates of the digital data are in hong kong 1980 grid, and heights are in metres above the hong kong principal datum
數據庫採用香港1980方格網座標系統,參照香港水平基準量度高度,以米為單位。Dynamic gas regulator can provide all air monitors with many kinds of gases whose concentration is very accurate. air monitor could be regulated through these regulating gases
動態氣體校準儀可以為各種氣體監測儀提供多種標準濃度的氣體,便於對氣體監測儀進行精確的校準,以保證其工作的精確度,從而得到準確的空氣質量監測數據。Standard visicosity measure
標準粘度測量First, the error transfer characteristic among subsystems at different space locations is analyzed, and the direct transfer characteristic from discrete standard measure space to the workpiece measure space under measured in measure system is proven. second, the error reconstruction condition and method of mapping from discrete standard measurement system to continuous standard measure space are analyzed. based on the measurement sample stationarity in limited distance, the prediction model ' s limited astringency and mensurability to the dynamic measuring error and the prediction error respectively are proven
分析了不同空間位置子系統間的誤差傳遞特性,證明了在測量系統中離散標準量值空間向被測量工件量值空間的直接傳遞性;分析了離散標準量系統向連續量值空間映射的誤差重構條件和方法;基於測量樣本的有限距離的平穩性,證明了預報模型對動態測量誤差的有限收斂性和預報誤差的可測度性,進而證明了以離散標準量值系統對被測工件預報修正的可行性和合理性。The prepared dna electrochemical sensor was used to determine the nature and quality of complementary dna of standard concentration. then the dna sensor was used to diagnose the clinical blood sample containing hepatitis b virus
利用製成的dna電化學傳感器對溶液中標準濃度的互補dna進行定性和定量檢測,並在此基礎上,將dna傳感器用於臨床乙肝病毒血清的dna診斷。The dual standard quantity ( the work piece and the discrete standard quantity ) mutual measuring and model verification methods are also proposed, which perfects the whole modifying process from data measuring, error separation, model establishment to real correction. after researching the discrete standard quantity system dynamic error separation technique, two error correction methods based on genetic algorithm and neural network mixed modeling technique are established. the two methods are the discrete standard quantity dynamic error direct / synchronous correction and prediction model correction ; the model ' s parameters and model ' s exercising method are also confirmed
設計了雙標準量值(工件和離散標準量)互比測量的模型驗證方法,完善了從數據測量、誤差分離、模型建立到實際修正的整個修正過程;研究了離散標準量系統動態誤差分離技術,建立了基於遺傳進化演算法與神經網路混合建模技術的兩種誤差修正方法? ?離散標準量動態誤差直接(同步)修正方法和預報模型修正方法,並確定了模型結構參數和模型訓練方法;分析了預報模型的多次預報性質,並得出了多次預報與多步預報的等效關系,確定了測量系統的有效預報范圍以及模型參數對泛化誤差的影響;進行了模型的對比實驗驗證和被測工件動態誤差修正試驗,成功地實現了任意二面角和圓分度的實時誤差修正。Test methods for water requirement of normal consistency, setting time and soundness of the portland cements
水泥標準稠度用水量凝結時間安定性檢驗方法Standard test method for water requirement of normal consistency setting time and soundness of the portland cement
水泥標準稠度用水量凝結時間安定性檢驗方法The best process of sulfomethylated poly ( maleic anhydride - co - acrylamide ) is also designed. by testing setting time and water reducing rate of water - reducing agent, we find that the water - reducing ratio of the monoesterified ma - am is 20 %, and the sulfomethylated ma - am is 6. 3 %. they both have good retarding performance
本文還對水泥標準稠度用水量與凝結時間進行測定,得出酯化改性的減水劑減水率達到20 ,磺甲基化改性的減水劑減水率為6 . 3 ,改性產物均有一定的緩凝性。Abstract : the paper say the principle and method of standard quantum insertion method used in the precision turn control of the machine arm, issue the method correctness and capability, and give the structure of standard quantum generator and interface method of location signal
文摘:本文敘述了標準量插入法應用於機械臂精密轉動控制的原理和方法,探討了該方法在實現上的技術可行性,給出角度標準量發生器的結構和定位信號的介面方法。Standard test methods for maximum index density and unit weight of soils using a vibratory table
使用振動臺測定土壤最大標準密度和單位重量的標準試驗方法Standard test methods for minimum index density and unit weight of soils and calculation of relative density
土壤最低標準密度和單位重量的標準試驗方法與相對密度的計算分享友人