比較校準 的英文怎麼說

中文拼音 [jiàojiàozhǔn]
比較校準 英文
comparison calibration
  • : Ⅰ動詞1 (比較; 較量高下、 長短、距離、好壞等) compare; compete; contrast; match; emulate 2 (比...
  • : Ⅰ動詞1 (比較) compare 2 [書面語] (計較) dispute Ⅱ副詞(比較) comparatively; relatively; fair...
  • : 校名詞1. (學校) school 2. (校官) field officer3. (姓氏) a surname
  • : Ⅰ名詞1 (標準) standard; guideline; criterion; norm 2 (目標) aim; target Ⅱ動詞1 (依據; 依照)...
  • 比較 : 1 (對比) compare; compare with; contrast; parallel (with); comparison; by comparison; in comp...
  1. Calibration specification for base circle pitch comparator

    基圓齒距規范
  2. Calibration specification for hand - hold pitch comparator

    手持式齒距規范
  3. The assembly language program collects and processes the data real time. comparing kinds of method of filter and arithmetic of fft, the author select the fir filter to realize pretreatment of signal and radix - 2 fft to distill the characters of librations

    通過對各種濾波方法和fft演算法進行,本套數據檢測和處理系統採用fir濾波對採集到的信號進行預處理,利用基2fft演算法來提取信號的頻率特徵。
  4. Wattmeters will be calibrated by direct comparison method against the laboratory standard wattmeter with phantom load

    功率表將透過直接法及用虛假負載,利用本所的標功率表,加以正。
  5. Calibration specification for optical comparators for angle measurements

    光學測角規范
  6. There are many methods for measuring impedance and commercial lcr meters may have very different working principles. it is more advisable that customers submit their impedance standards for calibration, which in turn can be used to perform in - house checking of their lcr meters. however, the laboratory may offer performance checks for lcr meters using impedance standards

    測量阻抗的方法有多種,故此市面上的電感電容電阻計或有截然不同的操作原理,一種適當的做法是客戶將其阻抗標器送來本所正,然後客戶可利用這些已正的標器替自己的電感電容電阻計進行測試。
  7. Method for calibrating field pyranometers by comparison to a reference pyranometer

    通過與標日射強度計的現場日射強度計方法
  8. Standard test method for calibration of pyrheliometers by comparison to reference pyrheliometers

    日射強度計與基日射強度計進行比較校準的標試驗方法
  9. The method using square wave excitation presented by the paper is verified by theories and experiments that the method meets the requirement of accuracy, and this method ' s application simplifies manipulations and improve greatly the calibration efficiency

    其中本文提出的方波信號激勵的比較校準法,理論和實驗證明不僅滿足精度要求,而且簡化操作,大大提高了的效率。
  10. Vacuum technology. ionization vacuum gauges. calibration by direct comparison

    真空技術.電離真空計.用直接
  11. In view of predecessors " research achievements we put forward a method using square wave excitation and the fast furrier transformation ( fft ) to realize the comparison calibration for the calibration system of piezoelectric accelerometer

    在吸收前人研究成果的基礎上,文中提出了工作用壓電加速度傳感器系統應用方波信號激勵,同時應用快速傅立葉變換( fft )的方法來實現
  12. The calibration of piezoelectric accelerometer is an important area of the shock and vibration measurement technology, and the calibrated piezoelectric accelerometer is divided into standard accelerometer and working accelerometer, usually standard accelerometer is calibrated by absolute method and working accelerometer is calibrated by comparison method

    壓電加速度傳感器的是振動與沖擊測量技術中的一個重要研究領域,被的壓電加速度傳感器有標加速度計和工作用加速度計之分,通常標加速度計用絕對法,工作用加速度計用
  13. Preparation of steel substrates before application of paints and related products - surface roughness characteristics of blast - cleaned steel substrates - method for the calibration of iso surface profile comparators and for the determination of surface profile - stylus instrument procedure

    塗塗料和有關產品前鋼基的制備.噴丸處理鋼基體的表面粗糙度.第4部分: iso表面輪廓儀的方法和表面輪廓的測定方法.觸針儀法
  14. Preparation of steel substrates before application of paints and related products. surface roughness characteristics of blast - cleaned steel substrates. part 4 : method for the calibration of iso surface profile comparators and for the determination of surface profile. stylus instrument procedure

    塗料和有關產品使用前鋼基片的制備.噴丸處理鋼基片的表面粗糙度特性.第4部分: iso表剖面儀的方法和表剖面的測定方法.觸針儀器的程序
  15. In this paper, we begin with actual products designs and then combine the real conditions. on condition that technique conditions requirements were satisfied, by adopting electromagnetic field numerical analysis and experimental research, the electric field distribution inter - phase and to ground of 12kv metalclad withdraw switchgear vacuum circuit breaker is described accurately. the electric field distribution and movement in different conditions are also confirmed

    本文從實際產品設計入手,結合現實情況,在滿足技術條件要求的基礎上,通過採用電磁場的數值模擬分析及實驗研究,確地描述了12kv配電系統中置櫃真空斷路器相間及對地全場域電場分佈情況,確定了中置櫃在不同情況下的電場分佈、變化情況,通過理論的計算和分析,對產品的絕緣進行了核與驗證,通過多種方法的,進而得到合理的布置結構和達到最佳的絕緣配合,為實際產品的開發和設計提供了理論依據。
  16. Based on the theory of system identification and experimental data, the simulating results of many kinds of parameter models have been compared. among them, we can find a parameter model that can precisely express the dynamic character of measurement system. on the system model constructed, the dynamic error of measuring data is processed by inverse filtering method

    本文先後對測試系統進行了多次動態,根據所得實驗數據在系統辨識理論的基礎上,了多種參數模型的模擬效果,尋找到一類能夠確地描述測試系統動態特性的參數化模型,並根據所建立的系統模型,採用反濾波方法改進了測試系統的動態特性。
  17. Center for comparative education of beijing normal university approved by the ministry of education as a key research institute of humanities and social science in universities

    中華人民共和國教育部普通高等學人文社會科學重點研究基地北京師范大學教育研究中心獲成立
  18. Vakuum technology ; standard method for vacuum gauge calibration by direct comparison with a reference vaccum gauge, ionization vacuum gauge

    真空技術.用參測量儀直接比較校準真空計的標方法
  19. Vacuum technology ; standard method for vacuum gauge calibration by direct comparison with a reference vacuum gauge, thermal conductivity gauges

    真空技術.通過與標真空規的直接比較校準真空計的標
  20. This article calculates the finite element modal using the different boundary condition of ccs, dnv, lr and gl, compares the calculation result with the permit stress to prove the safety of structure and then analyzes the results and comes to conclusion

    在計算中,本文分別按照ccs 、 dnv 、 lr 、 gl的邊界條件進行計算求解,將計算結果與ccs 、 dnv 、 lr 、 gl各自的強度標進行核船舶結構強度是否滿足要求。
分享友人