氣流閘 的英文怎麼說

中文拼音 [liúzhá]
氣流閘 英文
draft damper
  • : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : anchor gate
  • 氣流 : 1 [氣象學] air current; airflow; wind current; airstream2 [語言學] breath氣流紡紗 open end spinni...
  1. Ih = hold current - maximum current at which the device will not trip at 23 still air

    維持電,指在23度靜止的空環境中不會導致該設備『跳』的最大電
  2. Blank detail specification for thyratrons and gas - filled rectifier tubes

    管與充管空白詳細規范
  3. The results show that the damages to the appearance of concrete structures exposed to atmosphere, including honeycombing, cracking along rebar, rebar corrosion, and concrete delamination, are quite serious, that the poor quality of concrete construction, the insufficient thickness of local concrete cover, and the rebar corrosion expansion and dilatancy induced by carbonization of concrete cover are the main causes, and that the main form of damages to the overflow structure is the abrasion resulted from water scouring

    結果表明,水的水上(大中)混凝土結構外觀破損十分明顯,露石露砂、順筋裂縫、鋼筋銹蝕、混凝土破損剝落等已十分嚴重;引起破壞的主要原因是混凝土施工質量較差,局部保護層厚度不足,混凝土保護層碳化引起鋼筋銹蝕脹裂,而水沖刷磨蝕是水結構破壞的主要形式。
  4. Measuring of lightning parameters is the base work of lightning research. it is very important for researching the lightning characteristics, analyzing the accident of lightning, identifying the responsibility of lightning strike outage accident and discussing the strategies of lightning protection. it also can provide precise original data of atmosphere over - voltage for designing insulation co - ordination

    雷電參數的測量是進行雷電研究的基礎工作,對于研究雷電特性、分析雷害事故、鑒定雷擊跳事故責任、探討防雷對策及為絕緣配合設計提供精確的大過電壓原始數據均具有十分重要的意義。
  5. It can endure the surge current from connected capacitor banks without isolation and mechanical damage

    能承受與其配套的最大容量的電容器組合的沖擊,而不發生電絕緣閃絡擊穿和機械損傷。
  6. It = trip current - minimum current at which the device will always trip at 23 still air

    維持電,指在23度靜止的空環境中不會導致該設備『跳』的最大電
  7. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷路器所造成的事故無論是在次數,還是在事故所造成的停電時間上都占據總量60以上。因此,及時了解斷路器的工作狀態對提高供電可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷路器機械特性參數監測方法;提出了二次迴路保護器的概念,並將跳、合線圈完整性監視和二次迴路保護結合起來,給出具有完整性監視功能的二次迴路保護器實現方案;根據斷路器生產廠家提供的斷路器額定短路電分斷次數,計算每次分對應的觸頭電壽命損耗,預測觸頭電壽命;提出根據斷路器殼體溫度和斷路器周圍空溫度結合斷路器熱阻來計算斷路器主觸頭穩態溫升的方法,並根據此時的負荷電間接計算主觸頭迴路的電阻;在硬體電路設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用電壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作電壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  8. The flow regime inside of the tunnel, the characteristics of hydrodynamic load, the hydrodynamic pressure feature at the gate slot and the vent air speed during the shutting of the gate is studied through model test, and then the reliability of the gate, the feature of the vent air speed and the pressure at the gate slot during the shutting of the gate are analyzed based on the test result concerned

    通過模型試驗研究了事故門關閉過程中泄洪洞內的水態、門體的水動力荷載特性以及門槽段動水壓力特性、通孔風速,並根據試驗結果分析了該門動水下門過程中的可靠性,通孔風速特性和門槽段壓力特性。
  9. Secondly, discussed the selection of coolants. by comparing the different character of coolants, which used on the electrical equipments and newly developed ones, and analyzing the cooling condition in commute circuit, rl 13 was chosen for the research. thirdly, the article analyzed the impossibility of the evaporative cooling system of commute circuit and the importance of presser regulation system

    然後詳細闡述了製冷劑的選用原則,通過對以往電設備常用的製冷劑及新合成的製冷劑進行分析比較,根據不同製冷劑的特點,針對晶管在可控硅整電路中的工作特點,暫選氟里昂r113為本文實驗用冷卻介質。
  10. For fire grounding, grounded impedance varies greatly because of air dissociation, and this causes protection set to startup and resume again and again. therefore, the main protection of the fault line ca n ' t cut off the fault quickly and accurately, and may lead to overstep tripping of near lines " protection sets and eventually cause more serious faults on the power system

    同時故障電一般比較小,電突變也很小,有時呈緩慢上升的變化趨勢,對火焰接地來說,由於空游離的緣故,接地阻抗變化很大,使現有保護反反復復啟動、恢復,可能會導致相鄰線路、設備的保護越級跳,使電力系統出現更嚴重的故障。
分享友人