水泵結合器 的英文怎麼說

中文拼音 [shuǐbèngjiē]
水泵結合器 英文
fire department pumper connection
  • : 名詞1 (由兩個氫原子和一個氧原子結合而成的液體) water 2 (河流) river 3 (指江、河、湖、海、洋...
  • : 名詞(吸入和排出流體的機械) pump
  • : 結動詞(長出果實或種子) bear (fruit); form (seed)
  • : 合量詞(容量單位) ge, a unit of dry measure for grain (=1 decilitre)
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 水泵 : water pump; compressed water pump水泵房 pump house; 水泵缸套 hoghead; 水泵工 plugman; 水泵間 [土]...
  • 結合 : 1 (發生密切聯系; 聯合) combine; unite; integrate; link; binding; coalition; cohesion; connectio...
  1. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的變流量系統入手,研究了盤管換熱在部分負荷下流量與換熱量的非線性關系,分析了文獻中介紹的旁通管通流能力選擇的不足之處和一次系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次變流量系統中壓差旁通控製法、回溫度控製法、負荷控製法的精確性,並得出了在一次系統的工況轉換時,採用負荷控製法能使冷機組及其相應在啟停時的負荷變化范圍較小,更符建築物的冷量需求,節能效果較好的論。
  2. At first, modeling of these divvies by rate equations to obtain expressions for threshold and slope efficiency is given. on the case of this theory, the large numbers of literatures and datum are consulted, and the laser is home studied. through rationally selecting and improving the reflector surface, ensuring the beam quality, increasing farthest the absorption path, and improving effective pumping frequency ; through designing the water cooler of yag bar, the volume of laser is half the same internal and international production, and the output power is get to the extremum of the same international production

    並在此基礎上查閱了大量文獻和資料,對該種激光進行了深入的研究,通過對yag棒直徑的理選取併理地改進反射鏡面,從而既保證了光束質量又最大限度的增加了吸收長度,有效的提高了浦效率;在不影響浦的前提下,通過有效縮短yag棒的長度減小輸出損耗;對yag棒的冷系統進行優化構設計,使激光體積減小到國外同類產品體積的一半,而輸出功率已達到國外同類產品的極限值。
  3. Respective simulation of the liquid cooling system and the circulatory system of cooling fluid, which mainly concerns the simulation model of the four major components in the refrigerating system and the water pumps and heat exchangers in the cooling circulatory system. experimental research of the assembled system of liquid cooling system, which yields the system perform parameters of refrigerating capacity and resistance loss in different working conditions. collection and comparison of the experimental data got from simulation and experimental research, which proves simulation and the experiment result are well tallying, hereby, testifies the emulational veracity of the cooling system

    主要對製冷系統中四大部件和冷卻液循環系統中的、換熱進行了數學建模;利用組裝的液冷源系統進行實驗研究,得到不同的工況下系統的製冷量、阻力損失等系統性能參數;對模擬和實驗研究中得到的大量實驗數據進行匯總比較,發現模擬和實驗果吻較好,驗證了液冷源系統模擬的準確性。
  4. According to the supply system composed by parallel connection water pump, many kinds of operation proposals in a single pump were put forward to provide the greatest possible flow on both sides of the demarcation point in the scope of the flux changes ; identified the system of pumps, electromotor, speed governor imitate method of characteristics curve of the power device and its rotating speed, efficiency, energy consumption calculation under different condition ; the analytical methods used for the operational plan for comprehensive evaluation of the economic and safety and optimal results

    摘要針對由並聯組成的供系統,提出了在以單可能提供最大流量為分界點的兩側流量變化范圍內具有多種運行方案;確定了在不同工況下,該系統中、電機、調速特性曲線的擬方法及其各動力裝置中轉速、效率、能耗的計算式;採用解析的方法對各種運行方案進行了經濟性和安全性綜評價,並給出最優果。
分享友人