水流量熱器 的英文怎麼說

中文拼音 [shuǐliúliáng]
水流量熱器 英文
water flow calorimeter
  • : 名詞1 (由兩個氫原子和一個氧原子結合而成的液體) water 2 (河流) river 3 (指江、河、湖、海、洋...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 流量 : rate of flow; flow; runoff; discharge; throughput; (flow) rate; quantity (of flow); flux
  1. Heat convected, a mode of motion developed by such combustion, was constantly and increasingly conveyed from the source of calorification to the liquid contained in the vessel, being radiated through the uneven unpolished dark surface of the metal iron, in part reflected, in part absorbed, in part transmitted, gradually raising the temperature of the water from normal to boiling point, a rise in temperature expressible as the result of an expenditure of 72 thermal units needed to raise i pound of water from 50 to 212 fahrenheit

    燃燒所引起的運動形式之一-,不斷地加速度地從源體傳導給容中的液體,由那凹凸不平未經打磨的黑色鑄鐵面把向周圍發散出去一部分反射回來,一部分被吸收,另一部分被傳導,使的溫度從常溫逐漸升到沸點。這種溫度的上升可作為消費結果標志如下:將一磅從華氏五十度加到二百十二度,需耗七十二單位。
  2. For a soil or rock of water - lacked, a heat transfer theoretical model is developed, which is a steady or unsteady, the results show that reservoir temperature, thermal diffusion coefficient, inlet temperature, flow rate of and run time of ground source heat pumps have an effect directly on heat transfer process of dhe. it can deduce that intermit running is favorable for this type of soils and rocks

    對于貧含地下巖土層建立了穩態與非穩態傳的理論模型,分析結果表明,巖土層的儲溫度、導溫系數、埋地換溫度、以及地源泵系統的運行時間或開停機比,都對埋地換的傳過程產生直接影響,可以推斷,對于該類型巖土層的地源泵系統,採用間歇運行將是有利的。
  3. Choosing the thin silicon steel board to be the vortex heating board material can not only decrease the weight of water heater and make the water heater smaller, but also accord with the tending to skin effect

    選耿薄的硅鋼板作渦板的材料不僅符合渦的趨膚效應,還可以大大減輕的重和減小的體積。
  4. Through measuring residual swhirling flow field in the flue duct of a real boiler, and analysing layout features of front and back platen supe - heaters in large - scale tangential firing boilers, the flue gas energy distribution regularity in horizontal flue duct of tangential firing boilers has been studied

    摘要通過對實際鍋爐煙道煙氣殘余旋轉場的測及大型切圓燃燒鍋爐前、后屏過的布置特點分析,研究了切圓燃燒鍋爐平煙道煙氣能的分佈規律。
  5. The goal is to control the water outlet temperature by manipulating the flow rate of the steam and control the water inlet rate by manipulating the height of the water level in the water tank

    本文中,換的控制任務主要有兩個,首先通過控制箱進口閥門開度,進而控制位,進而控制換進口
  6. By using a same boundary dimensions high efficient and new type copper exchanger substituted carbon steel oil condenser, and increasing flow rate of circulation water to reduce the temperature of freezing oil which feeds into compressor stage, to eliminate the malfunction during compressor operation, and improve running efficiency of the machine

    採取將碳鋼材質的油冷卻更換成等外形尺寸的高效新型銅管換、增加循環的方法,降低了進入二段壓縮機冷凍油溫度,排除了壓縮機運行中的故障,改善了機組的運行效率。
  7. 3. on boiler retrofit, the calculation of fuel burning, the heat calculation of boiler inside structure and convection section, and the design of structure parameter of feed water heat exchanger are made. the flue gas channels " resistance calculation and the boiler strength verifying are also carried out. replacement of water cooling wall improves heat exchanging and decreases loss of heat radiant

    對鍋爐本體進行了燃料燃燒計算、爐膛結構力計算、對面結構力計算、鍋爐給結構參數設計、煙道阻力計算及鍋爐元件強度校核等;改進了冷壁布置使換效果更好,減少輻射換損失;改進對段結構,更充分的利用爐膛出口煙氣余,提高效率;並且進行了煙氣阻力計算、效率計算和能平衡測試,對改進后的稠油燃料和改進前進行了對比,燃燒狀況和效率有明顯改善。
  8. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的變系統入手,研究了盤管換在部分負荷下與換的非線性關系,分析了文獻中介紹的旁通管通能力選擇的不足之處和一次泵系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵變系統中壓差旁通控製法、回溫度控製法、負荷控製法的精確性,並得出了在一次泵系統的工況轉換時,採用負荷控製法能使冷機組及其相應泵在啟停時的負荷變化范圍較小,更符合建築物的冷需求,節能效果較好的結論。
  9. Various forms of combining parts of the invention, by which water in multi - stage recirculating water - heating tank for collector and / or multi - stage confluent water - heating tank, as a whole or separately, can be heated by solar energy collector, or a heat pump, or an electrical heater, fall into the following categories : on sunny day, it ' s enough to use the solar energy collector to heat water, then hot water is stored ; in confrontation with off - peak electricity at night, use the heat pump or the electrical heater to heat water, then hot water is stored ; during the time of a cloudy day without off - peak electricity, use the heat pump to instantly heat water according to the storage capacity of predetermined amount of produced hot water, then hot water is stored

    所述的經太陽能集、或泵、或電加裝置同時或分別對集循環加箱、分級加式匯箱中的進行分級加的組合包括:陽光天可全部採用太陽能集進行加和儲存,夜間峰谷電時段可採用泵或電加裝置進行補充加和儲存,無陽光的非峰谷電時段可根據定設置需求採用泵進行即時加和儲存
  10. An analysis is made of the causes for the problems of the decrease in quench water flowrate, abrasive wear of the coal water pipes, and blockage of the heat exchanger for ash water and the revamp measures, and after an inquiry into them, improvement measures are proposed

    摘要對氣化裝置激冷的降低、黑管道磨損、灰堵塞問題的產生原因及改造措施進行分析和探討,提出改進措施。
  11. There are five parameters need to be measured. there are five channels for input : the displacement of casting - roller, the rotate speed of casting - roller, the pressure of casting and rolling, the casting temperature and the water - speed of cooling water. they are measured by raster, photoelectric coder, strain pressure sensor, thermocouple and turboflowmeter

    系統需要進行監測的參數有五個,即有五路輸入信號:鑄輥位移、鑄輥轉速、鑄軋壓力、澆鑄溫度、冷卻速,分別採用光柵、光電編碼、應變式壓力傳感電偶和渦輪計作為檢測元件。
  12. Through developing a 2 - dimensions heat transfer model of buried pipe - in - pipe heat exchanger and simulating the process by computer, the author figures out inter - relations of factors which influence characteristics of buried pipe - in - pipe heat exchanger, such as pipe diameter, pipe length, ratio of pipe diameters, flow rate, inlet water temperature, patterns of water inlet and outlet, and material features made of pipe, and proposes some optimizing indexes of buried pipe - in - pipe heat exchanger. the author studies the " heat - - short circuit " phenomenon as well and gives < wp = 5 > some important results

    本文通過建立地下套管式埋管換過程的二維傳模型,並藉助計算機對分析結果進行解析,弄清了影響埋管換性能的管徑、管長、管徑比、通過、進溫度、進出方式以及管材等參數的作用,並提出了相應的優化指標,對研究界懸而未決的「短路」問題也進行了細致分析,得出了有關結論。
  13. Main contents for studying of the paper is : ( 1 ) analysing the outcome, characteristic and the problem of the hot water supplydesign second flow method in the europe and the usa. ( 2 ) it is determined that value frequenly of different fixture use in the period of using water high peak. ( 3 ) the relation between the n and the hot watersupply design second flow is got by applying program to computer under the different probablity

    本課題研究的主要內容為: ( 1 )分析對比歐美主要國家設計秒計算方法的結果、特點及存在的問題; ( 2 )根據我國居民生活用特點,由用標準推算出各類型用戶用高峰期的衛生具使用概率; ( 3 )編制計算機程序,計算不同使用概率情況下,給設計秒的關系表; ( 4 )建立設計秒q _ g和給n與使用概率p之間的相關關系; ( 5 )繪制《建築給設計規范》中有關設計秒計算方法的計算用圖表。
  14. The results show that while the mass flow of refrigerant is 1. 85g / s, the inlet temperature of refrigerant is 18. 9, the evaporating pressure is 0. 62mpa, the mass flow of water is 31. 1g / s, and the inlet temperature of water is 36. 9, the refrigerant of miniature evaporator wholly vaporizes in the tube, and the heat transfer rate is 342w. it achieved the demand of design

    經過實驗測試,當製冷劑質為1 . 85g / s ,製冷劑入口溫度為18 . 9 ,蒸發壓力為0 . 62mpa ,的質為31 . 1g / s ,的入口溫度為36 . 9 ,此時,螺旋管蒸發內製冷劑完全蒸發,換342w ,達到了微型蒸發的預期設計要求。
  15. At the same time, experimental study on boiling heat transfer by changing mass flow of refrigerant, mass flow of water, and inlet temperature of water was also finished. and then the performance of miniature evaporator was estimated

    本文完成了液單相、兩相平衡實驗和阻力特性實驗,研究了製冷劑在管內動的壓降;同時進行了微型蒸發動沸騰實驗,通過改變製冷劑質的質的進口溫度等,實現了對微型蒸發的性能評價。
  16. This new technology changes from the traditional method by which the induced and compressor wheel separately are designed and produced to a new one by which the one - piece compressor is designed. on the basis of this new technology and the optimum blade profile, the performance of both the compressor and the turbocharger is largely improved. through the heating power calculation of the compressor, the analysis of the surge and the block of the compressor, the test - bed performance test of the turbocharger, the matching test of turbocharger and diesel engine, the propulsion test of the turbocharger on plateau condition, it is proved that the newly - designed compressor not only has high efficiency, but also improves the flow distribution in the high efficiency area so that the propulsion line can run through the high efficiency area

    主要內容包括:提出一種全新的壓氣機葉輪技術和概念,這種技術將傳統的導風輪和壓氣機分開設計、單獨加工改為整體設計、整體加工的單體葉輪;從增壓與柴油機配機計算所得出的基本參數出發,通過對壓氣機進行力計算,確定壓氣機的基本結構參數;再對葉型以及葉輪輪廓與葉輪罩殼的配合間隙進行優化,對新設計的壓氣機進行喘振和堵塞分析;通過增壓平臺性能試驗,驗證了新設計的壓氣機的性能平得到了較大的提高,達到了提高增壓的整體性能平的目的;通過增壓與柴油機配機試驗、以及增壓用於高原條件下的牽引試驗,驗證了新設計的壓氣機不但具有高效率,還改善了高效率區的分佈,使牽引特性線貫穿高效率區。
  17. Measurements were made of system pressure, mass flow rate of steam, air, and cooling water, temperatures of condensing flow and cooling flow, and the water level of boiler. the major phenomena observed in the present experiment are similar to those by other investigators. the mass flow rate of steam, the system pressure and air content are the most important factors affecting steam condensation

    實驗結果表明,維持二次側冷卻不變,無論對于純凈蒸汽還是含有空氣的蒸汽冷凝,隨著蒸汽發生功率的增大(即蒸汽增大) ,有效冷凝段長度將加長;當蒸汽中含有少空氣,有效冷凝段長度也會明顯加長;提高系統壓力,有效冷凝段長度將縮短。
  18. The simulation results indicated that the air flow, airside pressure drop, water flow and flux of heat exchange in water side decreased with the increase of frosting time, and the airside pressure increased

    模擬結果表明,隨著結霜的增加,空氣側換的換減小,風也將逐漸減小,而阻力卻迅速增加;側換的換減小,也減小。
  19. Manual operating hot water flow through the radiator to control the room temperature, its most economical of thermostatic radiator valve. available for : 3 / 4 ", 1 / 2 " / style : straight valve, angle valve

    手動調節閥,通過手動調節散,以達到控制室內環境溫度的目的,是最經濟的散溫控閥。規格及型號: 3 / 4 」 、 1 / 2 」型式:直型、角型。
  20. In order to decrease heating of driving coil, the structures of electromagnetic circuit and offset magnetic circuit in actuator are carried out design calculation and experimental study, and the shapes of them are optimum designed. the effect of

    研究了驅動線圈的發對執行的微位移精度的影響,在驅動線圈內部設計了冷卻箱以抑制其發,給出了冷卻的計算公式,閑除了冷卻循環系統;以所u的磁場與位移感知型超磁致伸縮微位移執行為核心,構成其微位移驅動系統。
分享友人