水溫開關 的英文怎麼說

中文拼音 [shuǐwēnkāiguān]
水溫開關 英文
cts coolant temperature switch
  • : 名詞1 (由兩個氫原子和一個氧原子結合而成的液體) water 2 (河流) river 3 (指江、河、湖、海、洋...
  • : Ⅰ形容詞(不冷不熱) warm; lukewarm; hot; gentle; mild Ⅱ名詞1 (溫度) temperature 2 (瘟) acute ...
  • : Ⅰ動詞1 (使開著的物體合攏) close; shut 2 (圈起來) shut in; lock up 3 (倒閉; 歇業) close down...
  • 水溫 : water temperature水溫表 water-thermometer; water temperature gauge; 水溫自動調節器 aquastat
  1. Breaker, refrigerator over - load protection relay, refrigerant high pressure switch, air circulator thermal switch, fuse, overheat protector, alarm

    無熔絲,壓縮機超載保護,冷媒高壓保護,超保護盤缺保護,電磁,故障警告系統,警報器
  2. The central control room of the branch is located in the bank of communications plaza in the lujiazui, shanghai, which adopts the xbrother developed professional security and facility control system which monitors and controls 10 subsystems in the central control room, including : the ups control system ; the coulometer control system ; the leaking control system ; the temperature and humidity control system ; the air conditioning control system ; the video surveillance system ; the sensor of in out water temperature control system ; the access control system ; the switch control system and ; the fire alarm system

    交通銀行機房位於上海浦東新區陸家嘴金融中心的交銀金融大廈內,其機房監控系統採用我司自主研製的專業機房監控系統。對機房內的ups監控系統電量儀監測系統漏監控系統濕度監控系統空調監控系統視頻監控系統進出傳感器監測系統門禁監控系統狀態監控系統消防監控系統等10個子系統進行集中監控,對所有的設備和系統進行工作狀態運行參數報警處理等監視和管理。
  3. By investigation on the relationship between period, quantity, extend of ostrinia furnacalis emergence and meteorological factors in qiqihaer, this paper analyzes the factors which effect on period, quantity, extend of ostrinia furnacalis about annual wave. the beginning time of ostrinia furnacalis pupae emergence depends on average temperature in may and june, weather conditions in july decide whether ostrinia furnacalis pupae finish ahead of time ; the beginning time of eclosion is decided by average lowest temperature and precipitation in may and june, and the end time of eclosion is decided by average lowest temperature in june and july, meantime, the length of time of ostrinia furnacalis eclosion and time of grub emergence influence on the extent of ostrinia furnacalis. an important condition of a great emergence of ostrinia furnacalis is that how temperature matchs humidity, which substantially result in reduction of maize output

    本研究項目通過對齊齊哈爾市玉米螟發生期、發生量、發生程度與氣象條件系的分析,找出玉米螟發生期、發生量、發生程度年際波動的影響因子: 5 、 6月的平均氣決定了玉米螟化蛹始的早晚, 7月的天氣條件決定玉米螟化蛹是否提前結束; 5 、 6月的平均最低氣和降則決定羽化始的早晚, 6 、 7月的平均最低氣又決定了玉米螟羽化結束的早晚;而玉米螟羽化持續時間的長短和幼蟲發生的早晚影響了玉米螟的發生程度;濕條件配合適當與否是促使玉米螟大發生的重要條件,玉米螟大發生又會引起玉米的大幅度減產。
  4. The central authority - in - charge shall guide and assist persons who have developed hot springs prior to the enforcement of this act

    本法施行前,已泉使用者,主管機應輔導取得權。
  5. Safety device containing an audible alarm will break the circuit automatically when the pump is overloaded, temperature overheats or there is a shortage of oil or water

    設想周到的各種電子保護裝置,如無熔絲,缺或缺油,度異常及泵浦過負荷等自動警示系統,迴路能自動切斷,確保安全。
  6. Ctts coolant temperature thermo switch

  7. A 3 - d simulative calculation program concerning temperature field and creep stress field and its pre - processing and post - processing has been developed. by applying this program, temperature field and creep stress field of hydraulic culvert and sluice engineer concrete is simulated. 2

    發了非穩定度場和應力模擬計算的三維有限元計算程序及有限單元法的前後處理程序,運用此程序對工涵閘工程混凝土進行了度場和應力場的計算分析,得出相結論。
  8. Besides the basic requirements of a usual home heater like safety and auto - control on water temperature in tank, the new one was supposed to have more functions, the most important ones of which are temperature control on outlet and remote - switch on / off the machine

    本項目除了通常對電熱器的安全性和度的自動控制等要求外,還希望所設計的控制器具有恆控制、遠程控制等功能。
  9. Voltage meter, current meter, frepuency meter, oil pressure meter, water temperature meter, timer, battery voltage or charging current meter, protection indicator, speed and voltage inching switch and etc

    電壓表電流表頻率表油壓表表計時器電池電壓或充電電流表保護指示燈轉速及電壓微調等。
  10. This control system adopts creditable plc for real control ; it sends many simulating signals collected by old sand temperature of inlet, suction opening temperature of double disk, inner sand temperature of double disk, current of mainframe and current of fan ; meanwhile, the operation signal and switching value signal outputted by material movement transducer is inputted to switching value module of plc ; it gets evidence of water feeding after cpu account ; the operation result of cpu is outputted by switching value of plc to control unlock combination of coarse, middle and thin water feeding electromagnetically operated valve and then gets different water feeding quantity

    該控制系統採用高可靠性的plc可編程序控制器進行實時控制,傳感器所採集的入口舊砂度雙盤抽風口度雙盤內砂主電機電流及鼓風機電流等模擬量信號直接輸入plc的模擬量採集模塊,同時加砂設備運轉信號及加砂設備物料移動檢測傳感器發出的量信號輸入plc的量模塊,由cpu獲取經運算而得到加計算依據, cpu運算結果直接由plc的量輸出控制粗中細加電磁閥的啟組合,而得到不同的加量。
  11. The results of numerical experiments, using the four - dimensional variational data assimilation system of the nonhydrostatic mesoscale model mm5, show that : the tangent linear model and adjoint model conducted by keeping the " on - off " switches the same as the basic state, can provide a good approximation of the first - order information to the nlm perturbation and a good descent direction for the minimization procedure ; switching on and off at every other time step in the kuo cumulus parameterization scheme do n ' t impact the convergence rate of cost function ; the existence of the switches do n ' t impact improvement to the mm5 model rainfall prediction because that not only specific humidity, but also wind, temperature and pressure are assimilated into the model

    非靜力中尺度數值模式mm5的四維變分資料同化系統進行的數值試驗結果表明: 「」變量保持與基態一致,所構造的切向線性模式能夠提供于非線性模式擾動的一階近似,伴隨模式所計算的梯度值能夠為最小化過程提供較好的下降方向;郭氏降參數化方案中對流每隔一個積分步的交替發生並不影響目標函數最小化的收斂速度; 「」變量的存在也不影響將風、度、氣壓和比濕結合起來同化對mm5降預報準確性的提高。
  12. The information includes four types : six analog signals, such as oil quantity, voltage, oil pressure, water temperature, inside and outside temperature ; switching signals, such as the door, window, etc. ; impulse signals, such as car speed, and the rotate speed of engine

    研究了汽車在行駛過程中各狀態參量的數據採集。主要包括四類:油量、油壓、電壓、、車內度和車外度等6路模擬量,全部車燈的故障檢測量,車門、車燈、空調等車上常用量,車速、發動機轉速等。
  13. Ccevs coolant control engine vacuum switch

    冷卻控制引擎真空
  14. The controlling box collects the temperature and the humidity of the experiment box and the temperature of the water tank with platinum resistance transducer that has three paths. then they are sent to the microprocessor 89 c55 to dispose by a / d and sent to the d / a to be an 4 ~ 20 ma output of simulant value. at the same time, the outputs of six paths switch quantity drive respectively the relaies of heightening temperature reducing temperature alarm and so on

    「恆、恆濕控制箱」由三路鉑電阻傳感器採集試驗箱的度、濕度和箱的度,經12位a d送至微處理器89c55處理,送至d a輸出4 20ma模擬量,同時,輸出六路量分別驅動加濕1 、加濕2 、升、降、除濕、報警等繼電裝置。
  15. This water heater is equipped with a high limit control switch that is designed to shut off the power to the elements if the water temperature exceeds170 f ( 77 c )

    本熱器配置高限制控制,用於當熱超過77 c時,閉通向加熱元件的電源。
  16. Cvsco coolant vacuum switch cold open

    控真空冷車打
  17. Cvscc coolant vacuum switch cold closed

    控真空冷車
  18. This series of products can be applied to heating furnace, industrial kiln semiconductor stove, precise temperature control of reaction caldron, boiler heat treatment, temperature control and process control system field such as petrochemical industry light industrial machinery and so on. intelligent manipulator is matching product of pid regulator or dcs and other system, which mainly use to manual regulation under the system running or special condition and to carry out operate as a backup instrument when main machine has happened failure or maintenance. according to field regiurement

    具有5個模擬輸入in1 - in5 2個模擬輸出out1 out2 ,一個量輸入di , 2個量輸出和豐富的控制演算法,適用於鍋爐汽包位三沖量控制或兩沖量控制並可帶汽包位壓力補償功能適用於一般工業過程中度壓力液位流量等各種過程參數的串級控制,前饋控制雙路控制等,並可帶后備操作器。
  19. Replace the front cover. once the tank is full of water, plug in the water heater. turn the switch to " on " and set the temperature dial to the desired setting

    重新安裝前蓋板。等到容器注滿后,將熱器插頭插上。將撥到" on "的位置打電源,將度刻度設置在所需要的度。
  20. Unnecessary energy consumption was cut as far as possible by a series of housekeeping measures such as setting a higher room temperature for cooling systems or reducing water temperature for gas boilers, encouraging staff to use staircases for inter - floor traffic, shortening operation hours of lifts, and routine checking to switch off lights and air conditioners both within and outside office hours

    為盡量減少不必要的能源耗用量,警隊已採取一系列環保管理措施,如調高冷卻系統的室或降低氣體鍋爐的、鼓勵員工使用樓梯、縮短升降機的運作時間,以及經常巡視,確保人員在離辦公室時及辦公時間后掉電燈和冷氣機。