水蒸氣小管 的英文怎麼說

中文拼音 [shuǐzhēngxiǎoguǎn]
水蒸氣小管 英文
gut
  • : 名詞1 (由兩個氫原子和一個氧原子結合而成的液體) water 2 (河流) river 3 (指江、河、湖、海、洋...
  • : Ⅰ動詞1. (蒸發) evaporate2. (利用水蒸氣的熱力使食物熟或熱) steam Ⅱ名詞[中醫] (將藥物隔水蒸熟) steaming
  • : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
  • : Ⅰ形容詞1 (體積、面積、數量、強度等不大) small; little; petty; minor 2 (年紀小的; 年幼的) youn...
  • : Ⅰ名詞1 (管子) pipe; tube 2 (吹奏的樂器) wind musical instrument 3 (形狀似管的電器件) valve;...
  • 水蒸氣 : steam; vapour; water vapour
  1. The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    建立了空冷卻實驗臺,熱的加熱方式為電加熱,工質為.在1 1模型上對分離式熱內凝結換熱特性、不凝性體對凝結換熱的影響及不凝性體的擴散規律進行了試驗,得出分離式熱有一最佳充液率,其值為45 %左右;凝結換熱系數隨著汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性體對分離式熱的凝結換熱僅影響冷凝段下部較部分,通過排閥排出不凝性體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性體對分離式熱冷凝段的影響減少.這些結論可用於分離式熱換熱器的工程設計和控制
  2. Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    文摘:建立了空冷卻實驗臺,熱的加熱方式為電加熱,工質為.在1 1模型上對分離式熱內凝結換熱特性、不凝性體對凝結換熱的影響及不凝性體的擴散規律進行了試驗,得出分離式熱有一最佳充液率,其值為45 %左右;凝結換熱系數隨著汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性體對分離式熱的凝結換熱僅影響冷凝段下部較部分,通過排閥排出不凝性體可有效地改善冷凝段下部的凝結換熱;隨著壓力的增加,不凝性體對分離式熱冷凝段的影響減少.這些結論可用於分離式熱換熱器的工程設計和控制
分享友人