測脈 的英文怎麼說

中文拼音 [mài]
測脈 英文
pulse taking
  • : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
  • : 脈名詞1. (動脈和靜脈的統稱) arteries and veins2. (脈搏的簡稱) pulse 3. (像血管的組織; 連貫成系統的東西) vein
  1. After purging, oxygen pulses are injected until the detection system no longer indicates oxygen adsorption.

    脫氧后,注射氧沖直到檢系統表明不再有氧吸附為止。
  2. We prospectively investigated whether measurements of carotid intima - media thickness in the presence or absence of albuminuria in patients with stable chest pain syndromes can be used as a noninvasive test algorithm for prediction of significant coronary artery disease

    前瞻性研究穩定性胸痛綜合征患者在有/無蛋白尿時的頸動內膜中層厚度量能否作為預重要冠狀動疾病的一種無創性檢查方法。
  3. It is proved that the electric conductivity of ore - forming solution can be used to seek for ore - forming fractures, to select the best mineralization section, to distinguish industrial and non - industrial auriferous quartz veins, to reflect the rich or poor levels of orebodies, to evaluate the stability of orebodies, to judge the denuding levels of ore veins, and to prospect the mineralization in depth

    實踐證明,該方法在以下幾個方面具有應用前景: ( 1 )查找成礦斷裂,優選最佳成礦區段; ( 2 )區分有無工業價值的含金石英; ( 3 )反映礦段或礦體的貧富程度; ( 4 )評定礦體的穩定性或礦化不均勻性; ( 5 )評估礦的剝蝕程度; ( 6 )礦深部成礦預
  4. Trial 3, effect of supplemental copper of different type on no - specific immunity of mice the grouping of experiment animal was the same as trial 1, at 7th, 14th, 21th, 8th, one mouse was injected diluent chinese ink for 10mg / kg avoirdupois with 4 times after weighing, blood was made from eyepit in time of second and 20th minute after injecting, killing the mouse immediately, weighing the liver and spleen, calculate the correct phagocytic index

    試驗三,不同形式銅對小鼠非特異性免疫功能的作用試驗動物分組同試驗一,進入正式試驗期后,在第7天、 14天、 21天、 28天每重復選取1隻小鼠,稱重后按10ml kg體重尾尖靜注入4倍稀釋的中華墨汁,注入墨汁后2min和20min分別從眼眶取血吸光值,最後一次采血后立即處死小鼠,取肝臟和脾臟稱重,計算矯正吞噬指數。
  5. By using the processing method of sliding time window, the problem of the periodicity range ambiguity is solved. meanwhile, the problem of range ambiguity which is produced because the range of target is biger than the maximum range of radar is also solved by using this method. then, the pulse width parameter which is the most important in the parameters of fmicw is analyzed. the stricter restrict is given to ensure the range spectrum has only one beat frequency after signal processing. at last this thesis introduces the different signal processing methods of fmpcw and fmicw

    同時利用該方法解決了fmpcw信號的由於目標距離超過雷達的最大單值距范圍而引起的距離模糊問題。然後對fmicw波形參數中最為重要的沖寬度進行了分析,給出了更為嚴格的約束條件,保證了信號處理后距離譜峰值的唯一性。最後,分別介紹了fmpcw和fmicw信號的不同處理方式,並對兩者不同的時域濾波性能進行了比較,並對二者的差異進行了分析。
  6. Based on the analysis of the beat frequency signal, the expression of the beat frequency phase is deduced. the expression indicates physics meanings of quantities to be detected and supplies theoretical bases for detection methods. by using two - dimensional fft, the range and velocity information of target is got out from the echo. according to the periodicity range ambiguity of symmetrical pulses in fmpcw, the processing method of sliding time window is used

    通過對差頻信號進行的分析,得出了差頻相位的具體表達式,表現出了要檢的各量的物理意義,對檢的方法提供了理論依據。利用二維fft方法,可以有效地提取回波中目標的距離與速度信息。對于fmpcw信號由於均勻沖產生的周期性距離模糊的問題,採取時間波門的處理方法。
  7. The application of cdfi in carotid artery in cerebral infarction

    彩色多普勒血流顯像對腦梗死頸動的檢
  8. The advantage and disadvantage of measurement of propeller - induced pressure by using different equipment is discussed. the method to obtain self - propulsion point for full scale in depressurized towing tank is studied. the measurements of pressure of two propeller models are carried out, the results of the measurement agree with those obtained by cavitation tunnel very well, which proves this measurement is successful, and the theoretical prediction is verified too

    比較了不同試設備用於螺旋槳動壓力試的優缺點,探討了在減壓拖曳水池中實現實船自航點的方法,並進行了兩只螺旋槳模型的動壓力試,經與空泡水洞中動壓力的試結果進行比較,說明該項試是成功的,同時也對動壓力的理論預報結果做了驗證。
  9. Msct had a low sensitiity for detecting lesions in the left circumflex artery ( 59 % ) and in the right coronary artery ( 52 % ), the inestigators note

    研究者表示,多層螺旋ct對于檢出冠狀動左迴旋支和右冠狀動的損傷情況靈敏度較低,前者僅有59 % ,而後者也只有52 % 。
  10. The results show that the measurement result is in concordance with the result of calculation by theory on powder - pulse - booster impulse

    研究結果表明:單擺試驗量火藥沖助推器沖量結果與理論計算結果基本一致,證明了此實驗方法的正確性。
  11. Other common devicesintravenous medication pumps allow the nursing staff to titrate medications ; foley catheters and urine collection bags aid in monitoring urine output ; sequential compression devices squeeze the lower extremities and reduce the incidence of deep venous thrombosis ; transvenous pacemakers stimulate the patient ' s heart to beat ; dialysis machines remove fluid and correct electrolyte and acid - base disturbances ; intraaortic balloon pumps assist the heart ' s contractility ; and neurologic monitoring systems measure intracranial pressure

    其他常用裝置靜內給藥泵由普通護士用於滴定藥物;弗利氏導管和集尿袋幫助監排尿量;連續壓迫裝置擠壓下肢,減少深部靜血栓形成;經靜起搏器刺激病人心臟跳動;透析儀除去液體,糾正電解質和酸堿紊亂;主動內氣囊泵支持心臟收縮;神經病學監系統定顱內壓。
  12. The background count of the detector is 4~6 counts 1 min.

    器的本底計數率為46沖1分。
  13. Ion detection technique has been successfully used in the study of rydberg states of na2 by pulse optical - optical double resonance. high - lying rydberg states near ionization limit have been observed and high sensitive and high gain spectra have been obtained. this technique is very useful for molecular spectroscopy

    本文首次實現了鈉分子體系中離子探測脈沖激光光譜,研究了鈉分子電離限附近的高里德堡態,獲得了高靈敏度和高增益的光譜,拓寬了分子光譜研究領域。
  14. The project adopts pulsed laser ranging in noncoherent detect mode, uses a 905nm pulsed laser diode as the laser source, detects object with a single apd, adopts an optics - mechanics scanner in object space to obtain images, and obtain distance images and intensity images of object simultaneously

    該研究方案採用直接探測脈沖激光距體制,以波長為905nm的沖半導體激光器作為激光光源,利用單元apd探器進行探,採用物空間掃描的光機掃描方式進行掃描成像,能同時獲得目標的距離圖像和強度圖像。
  15. For example, the simultaneous multiple wavelength observation of certain pulsars help astronomers to more precisely determine their radiation emission mechanism

    例如利用這觀法來觀測脈沖星,可幫助天文學家確定其輻射發放機制。
  16. Our item choiced msp430f149, a sort of singlechip as controller, designed our hardware electrocircuit to get the pulse wave singnal, and used msp430f149 to continuously search and calculate the peak - peak value of the pulse wave, and compute oxygen saturaction. in our study, in order to hurdle the dirft of baseline caused by the physiological difference of human bodies. we designed one circuit which can automatically regulate of the baseline of signal

    本文以msp430f149晶元為控制器,設計硬體電路提取搏波信號,連續檢測脈搏波峰?峰值,計算氧飽合度。本課題採用了基線自動調節電路,以克服不同人體生理差異引起的基線漂移;設計了直流截取電路和可控積分放大電路,以滿足臨床連續監的特殊需要,解決信號飽和問題。
  17. According to the distribution of local impulse noise, an adaptive chord deviation method is used to avoid redundant detection or missing of impulse noise at the quick rising, descending or broken line area of data set

    摘要針對現有沖噪聲濾波演算法在處理大斜率區域和斷線型激光掃描數據中存在的多判和漏判問題,提出了一種有效檢測脈沖噪聲的方法。
  18. Regard how to structure the control system of sensorless bldcm with dsp - tms320f240 as the centre in this paper, the detailed argumentation course of the motor startup, bemf terminal voltage measurement and control strategy is given out, give and pay concrete details for the software and hardware realization and experimental result. in order to treat the bldcm control system with dsp clearly, the full paper divides into six chapters altogether : chapter one, introduceing the development course, the structure characteristic and operation principle, etc. of bldcm in the introduction ; chapter two, directed against the startup issue of bldcm, the chapter give and publish the rotor measure pulse orients technology for motor startup in detail ; chapter three, proceed with mathematics model of the bldcm, expounding the control schemes ; chapter four, two important devices introducing : dsp ( 240 tms320f ) and power invertor control chip ( ir2131s ) ; chapter five, give and publish the detail of hardwares of control system ; chapter six, by ccs ide of ti, realize the control schemes in the front chapters with software, offere the procedure flow chart of main subroutine and some key place of programming, the experiment result in addition

    全文共分六章:第一章、緒論中介紹了bldcm的發展歷程、電機本身的結構特點和工作原理等;第二章、針對五位置傳感器bldcm的起動問題,文中詳細給出了檢測脈沖轉子定位起動技術;第三章、從電機的數學模型入手,詳細論述了反電動勢端電壓法和系統的控制策略;第四章、介紹了硬體實現中的兩個重要器件: dsp ( tms320f240 )和功率管逆變器控制晶元( ir2131s ) ;第五章、詳細給出了控制系統的硬體實現細節;第六章、利用ti提供的ccs集成開發環境,將前面章節的控制方案用軟體加以實現,給出了主要部分的程序流程圖和一些編程要點以及實驗結果。
  19. 3. with a view to the theory of surveying frequency on equal precision, introduces the realization of surveying frequency

    3 .從等精度頻法的原理出發,介紹了頻電路的實現方法,並對其頻和測脈寬等功能的實現進行了詳細介紹。
  20. The main purpose of this research on the chinese medicine diagnosis by feeling the pulse is to replace the doctor s fingers with a pulse detecting device to examine the pulse wave, which is converted into digital signal s and fed into a computer system through the usb interface. the viscosity of blood is distinguished whether the amount is normal or not by examining the pulse wave via the computer analysis

    本研究的主要目的是將中醫診的方式電腦化,即利用搏感器取代手指量測脈搏波形,再將它換成數位信號,並透過usb介面傳入電腦,經運算分析辨識后,顯示量測脈搏波形的血液黏度是否正常。
分享友人