  1. On one hand, the enterprise securicor bankenservice gmbh gladly signs your enterprise under the number + 49 561 99 87 - 0 pertinent statements and cost information on safety, admission control, value transport and both on safety systems and fire alarm systems on the other hand

    Securicor bankenservice gmbh是一家現代化的、可靠的專門產品供應商,這家供應商從事安全系統,火警信號裝置器,圖像監控系統,進入監控系統的製造、銷售。
  2. It realizes the functions of storing and transferring the information of fire alarm, displaying time, scanning keyboards, the safe maintenance of system and so on. the part of wireless communication is controlled by at89c2051 mcu, mainly realizing transmitting and receiving data between controller and other detectors. the external signals received by a wireless module are transmitted to mcu through shaping circuit, and the signals of mcu are transmitted by a wireless module through tone modulation circuit

    人機交互部分以單片機c8051f020為核心,為用戶提供一個良好的操作環境,實現了災報息的存儲及調用、時間的顯示、鍵盤的掃描、系統的安全維護等功能;無線通部分由單片機at89c2051來控制,主要實現控制器與其它探測之間的無線發射和接收,無線通訊模塊接收到的外部經過整形電路送入單片機,單片機發出的經過音頻調制再由無線通訊模塊發送出去,這樣實現了數據的無線傳輸;本文還從節能的角度出發,兼顧性能的可靠性,提出了一種合理的無線災報息傳輸模式。
  3. The traditional fire alarm systems are composed of a controller and detectors, and always transmit signals in the way of wireline transmission. however, the problems of long construction period, high rate of hardware fault and high cost of transmission line puzzle the administrators of fire control. but wireless communication in place of wireline communication can solve these problems effectively

    傳統的集散式災自動報系統由災報控制器及災探測組成,其傳輸方面多採用有線傳輸,但是這種形式下的災自動報系統的施工工期長、硬體故障率高、傳輸線成本高等問題常常困擾著消防管理人員,而以無線通代替有線通卻能夠很好地解決這些問題。
  4. Ecr fire alarm should be separate from the fire detection unit failure or must have two different messages

    集控室消防報應與煙探測失效(報)分開,否則必須設有兩個不同的息。
  5. 14 the boiler control board should have necessary sound and light alarming signals, such as flame display, water line, pressure, temperature and other protection device etc

    14鍋爐操作盤上應設有必要的聲、光報,如焰顯示、水位、壓力、溫度高低以及各種保護動作等。