無功功變計 的英文怎麼說
中文拼音 [wúgōnggōngbiànjì]
無功功變計
英文
varmeter-
To eliminate the bootless power dissipation of the redundant transition of the clock, a design method named det ( double - edge - triggered ) shift register is proposed
摘要從消除時鐘信號冗餘跳變而致的無效功耗的要求出發,提出雙邊沿移位寄存器的設計思想。Then, we propose a design method named det ( double - edge - triggered ) shift register to eliminate the bootless power dissipation of the redundant transition of the clock
接著,從消除時鐘信號冗餘跳變而致的無效功耗的要求出發,提出雙邊沿移位寄存器的設計思想。In this thesis a fuzzy control system used in voltage and reactive power auto regulatory device is designed based on the nine - zone controlling principle. in the fuzzy system, the fuzzy reasoning is mamdani method and the antifuzzy is centroid method. the software matlab is used to calculate the fuzzy system. the fuzzy system divide the voltage - reactive pane into fuzzy zone, in this way the domain - swing between closing domain is eliminated
論文對電壓無功綜合控制技術進行研究,針對傳統九區域分區控制方法無視電壓與無功耦合的缺點,結合變電站電壓無功控制的實踐經驗,在傳統控制方法上引入模糊控制,設計了基於模糊控制的電壓無功綜合控制系統。模糊推理系統中採用mamdani型推理,非模糊化採用重心法,設計中使用matlab進行輔助設計和離線計算。Now the affect and the measure of hypo _ harmonics is in the research. the influence of negative sequence is almost eliminated along with the enlargement of the system ' s capacity and the alternate connection of traction substations. the fixed parallel compensate equipment applied in traction substations consist of a constant capacitor and a constant inductance, so its output is constant
負序電流的問題已經因系統容量的增大、牽引變電所採用輪換接線方式而基本解決,電力部門實行的「反轉正計」 ,使採用對無功功率固定補償方式由於牽引負荷變化頻繁而出現補償容量不足或過補償現象,難以達到滿意效果。The methods of adopting fpga to realize the function of counter, and adopting verilog hdl hardware description language to design every function modules, not only makes the whole design more compact and stable, but also make the alteration of the circuit ’ function merely need to alter the software according to the practical task requires, and needn ’ t alter the hardware connection of the circuit
在計數器功能的實現上採用fpga ( fieldprogrammablegatearray ) ,利用veriloghdl ( hardwaredescriptionlanguage )語言編寫了各個功能模塊,不僅使整個設計更加緊湊、穩定且可靠,而且可以根據實際的任務要求,在無需改變硬體電路板的情況下,通過修改硬體描述語言程序,即可修改電路功能。Technical regulation for designing of reactive power compensation equipment for 330 500kv substations
330 500kv變電所無功補償裝置設計技術規定With the consideration of most of our transformers " taps are changed manually and some fluctuate unnecessarily, this paper presents a supervision system of oltc based on plc control technique. then we combine this system with reactive power compensate device such as shunt capacitor to design a new supervision system of substation voltage and reactive power synthetic control based on plc fieldbus
針對國內變電站電壓調整大多依靠人工調節,且有載調壓變壓器( oltc )分接頭動作頻繁的特點,本文提出了基於plc控制技術的有載調壓監控系統的研製方法,並以此監控系統為基礎,結合併聯補償電容器組等無功補償設備,設計了一種基於plc現場總線的變電站電壓無功監控系統。This approach is called fas. this approach uses characteristics of trigonometric function, respectively computes the amplitude of fundamental component and inactive power current separates them by low pass filter and acquires and inactive power current
該方法利用三角函數的特性,對畸變電流中的基波成分和無功電流分量的振幅分別進行計算,然後經過低通濾波器把它們分離出來,最後得到基波有功和無功電流分量。The study bases on the four operating conditions of which the longnan network will be implemented in the year of 2005 and 2010. first, this paper calculates the power flow distribution that including the line charging reactive power and input of the low - voltage shunt reactor in chengxian s / s. assumed that the bus voltage of tianshui s / s and bikou power plant to be constant, the study count the voltage level of the 330kv and 220kv bus - bar when the 330 / 220kv transformer in standard tap changer position. in order to set control rules
本文基於隴南電網在規劃發展水平年2005年及2010年的四種可能的運行方式下及潮流條件,計算出了計入線路充電無功及投入成縣變低壓並聯電抗器后的潮流分佈,在設定甘肅大網側及碧口電廠側母線電壓恆定條件下,計算了330kv及220kv主變在有載調壓標準分接頭變比下的330kv及220kv母線電壓水平。Secondly, to achieve the independent regulation of active and reactive power output from the generator side which is designed for the purpose of tracing the maximum wind - energy capturing. the paper has analyzed the mathematic model of the ac excited doubly - fed machine and the stator field orientation control strategy of the motor as vscf wind power generator. thirdly, it has put forward and designed the dual pwm converter with the capacity of energy flowing bidirectional aimed at the demand of rotor energy bidirectional flow. the author constructed reliable and integrated experimental system and did a series of experimental study including no - load, cutting - in network and power generation at, below and above the synchronous speed
論文首先分析了風機運行特性及其最佳風能利用原理,通過模擬及實驗驗證了採用直流電機的輸出特性模擬風力機的最大輸出功率曲線的可行性,並給出了模擬系統的硬體結構;然後為了實現交流勵磁發電機有功、無功功率獨立調節機理,分析了交流勵磁雙饋發電機的數學模型和在追蹤最大風能捕獲變速恆頻風力發電時必需的定子磁鏈定向矢量控制策略;針對雙饋發電機轉子能量雙向流動的要求,提出並設計了具有能量雙向流動能力的雙pwm交流勵磁用變頻器;最後為實現從理論到實踐的全面研究,研製出了一套小功率完整的雙pwm變頻器交流勵磁的雙饋風力發電機實驗系統,進行了空載、並網、同步速及上、下的發電運行等一系列的運行實驗;所完成的模擬和實驗研究均驗證了理論、模型和控制策略的正確性、可行性。The power angle characteristics are acquired and compared with the unsaturated curves. it is concluded that the stability limit of the power angle is less than 90 degree. reactive power regulating curves are calculated and compared with those curves when saturation effect is not considered, the result is that u type curves are deviated to the right
通過對同步發電機各種運行曲線的計算,在已有文獻的基礎上更進一步分析了鐵磁材料飽和以及磁場畸變對同步發電機運行特性和參數的影響;求出了空載特性曲線和零功率負載特性曲線,在不同的電樞電流下計算得到的波梯電抗不同;求出了功角特性曲線,與不計飽和時的功角特性曲線相比較,功角穩定極限小於90 ;求出無功調節曲線,與不計飽和時相比較, u型曲線向右偏移。Through theoretic reckoning and simulating analyzing, several control strategies for shunt apf were compared and chose ip - iq arithmetic of the instantaneous reactive power theory control strategy as the right scheme to produce the instructing current. based on it, some new control arithmetic was subjoined to suppress the resonance in system and balance the dc side capacitor voltage. two topologies of main circuit were compared and chose the three - phase voltage - source converter with a split - capacitor as its main circuit structure
通過理論計算和模擬分析,比較了並聯型apf的幾種控制策略的優點和缺點,從中選擇瞬時無功理論控制策略i _ p - i _ q計算方式為指令電流產生的演算法,並在此基礎上增加了抑制系統諧振和平衡直流側電容電壓的控制;比較了並聯型apf主電路的兩種常見形式,從中選擇了三相電壓型變流器的主電路形式;算出適合該apf的直流側電容和出線電感的參數;設計出能有效消除apf產生的高次諧波的高通濾波器。The basic software consists of topology analysis, on - line load flow computation, state estimator, security analysis, dispatchers training simulator, short circuit current computation, and voltage / reactive power optimize, etc. the derived softwares consist of load control, capacitor optimizer configuration, transformer and feeder load distribution, impedance computation of generator, etc. network analysis software is powerful dispatch tool, though witch the current state of the power system can be realize, then improve the security and economic potential
Dms網路分析的基本軟體有:網路結線分析、潮流計算、狀態估計、負荷預報、短路電流計算、電壓無功優化等。派生軟體有:負荷控制、電容器優化配置、變壓器與饋線負荷分配、電源阻抗計算等。網路分析軟體是有力的調度工具,通過它可以了解和掌握當前的運行狀態,從而挖掘安全和經濟方面的巨大潛力。By analyzing the load factor and unbalance factor of distribution transformer, the method of calculating and selecting the low voltage reactive power compensation capacity and compensation equipments, and the connection mode of capacitors were presented
摘要通過對配電變壓器負載率和不平衡率的分析,提出低壓無功補償裝置補償容量的計算選擇方法和電容器的接線方式。In order to instantly and real time eliminate harmonic and compensate reactive power, the definition of traditional reactive power, an integral average during a period, which is confined to apply under some circumstances. for example, when the load power varies swiftly, it will lead to can " t compensate reactive power rapidly
為了實時、快速的補償無功功率和消除諧波,傳統的基於平均值計算出來的功率因數,是以一個周期內積分而得出來的平均值,這在某種情況下就限制了它的應用,如系統負載功率快速變化時,就不能做到迅速、實時地補償無功。Intelligent tri - phase ac active reactive power instrument adopt advanced microprocessor carry out smart control, and to the inputed tri - phase ac voltage and current signal carry out accurate measurement, through cpu automatically count out the tri - phase ac active reactive power value total power, conduct clear and visual display by high brightness led display tube, it can be simultaneously transferred to standard voltage current signal to transmit output, and have super - limit control alarm standard serial communication function etc
智能三相交流有功無功功率儀表採用先進的微處理器進行智能控制,對輸入的三相交流電壓與電流信號進行精確的測量,經過cpu自動計算出三相交流有功無功功率值總功率,由高亮度led數碼管進行清晰直觀的顯示,同時可轉換成標準電壓電流信號變送輸出,並具有超限控制報警標準串列通訊等功能。Adopt advanced microprocessor carry out smart control, and to the inputed tri - phase ac voltage and current signal carry out accurate measurement, through cpu automatically count out the tri - phase ac active reactive power value total power, conduct clear and visual display by high brightness led display tube, it can be simultaneously transferred to standard voltage current signal to transmit output, and have super - limit control alarm standard serial communication function etc
採用先進的微處理器進行智能控制,對輸入的三相交流電壓與電流信號進行精確的測量,經過cpu自動計算出三相交流有功無功功率值總功率,由高亮度led數碼管進行清晰直觀的顯示,同時可轉換成標準電壓電流信號變送輸出,並具有超限控制報警標準串列通訊等功能。The hardware design and its main features of a voltage and reactive power integrated control device which is based on pc industrial control were introduced
摘要介紹一個基於pc工控機的變電站電壓無功綜合自動控制裝置的硬體設計及其主要特點。On the base of it, a piece of data collection special chip with a core of fft is designed with vhdl ( vhsic hardware description language ) in the way of top down system design method, which can finish harmonic analysis and measure the voltage, current, frequency and power of the electric power system
在此基礎上,使用標準的硬體描述語言vhdl設計出一個fft變換內核,並以該內核為核心、採取自上而下的系統設計方法完成了一個電力系統數據採集專用晶元的設計,實現對電力系統的電壓、電流、頻率、有功和無功功率等參數的測量以及各次諧波分析。In chapter 4, a basic controller of hvdc is designed. for the voltage problem at the inverter, this paper adopts the constant reactive current control at the inverter, which is different from the traditional control method. the constant reactive current control can adjust reactive power consume at the inverter and improve the voltage stability
在第四章hvdc基本控制器的設計中,針對逆變站消耗無功功率與電壓穩定性之間的矛盾,在逆變側採用了有別于傳統方式的定無功電流控制,目的在於調整逆變側吸收的無功功率,從而獲得較好的電壓穩定性。分享友人