熱擴散分離管 的英文怎麼說

中文拼音 [kuòsǎnfēnguǎn]
熱擴散分離管 英文
thermal diffusion column
  • : 動詞(擴大) expand; enlarge; extend
  • : 散動詞1. (由聚集而分離) break up; disperse 2. (散布) distribute; disseminate; give out 3. (排除) dispel; let out
  • : 分Ⅰ名詞1. (成分) component 2. (職責和權利的限度) what is within one's duty or rights Ⅱ同 「份」Ⅲ動詞[書面語] (料想) judge
  • : Ⅰ動詞1 (離開) leave; part from; be away from; separate 2 (背離) go against 3 (缺少) dispens...
  • : Ⅰ名詞1 (管子) pipe; tube 2 (吹奏的樂器) wind musical instrument 3 (形狀似管的電器件) valve;...
  1. The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    建立了空氣冷卻實驗臺,的加方式為電加,工質為蒸餾水.在1 1模型上對內凝結換特性、不凝性氣體對凝結換的影響及不凝性氣體的規律進行了試驗,得出有一最佳充液率,其值為45 %左右;凝結換系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對的凝結換僅影響冷凝段下部較小部,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換;隨著壓力的增加,不凝性氣體對冷凝段的影響減少.這些結論可用於器的工程設計和控制
  2. Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    文摘:建立了空氣冷卻實驗臺,的加方式為電加,工質為蒸餾水.在1 1模型上對內凝結換特性、不凝性氣體對凝結換的影響及不凝性氣體的規律進行了試驗,得出有一最佳充液率,其值為45 %左右;凝結換系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不凝性氣體對的凝結換僅影響冷凝段下部較小部,通過排氣閥排出不凝性氣體可有效地改善冷凝段下部的凝結換;隨著壓力的增加,不凝性氣體對冷凝段的影響減少.這些結論可用於器的工程設計和控制