熱水地 的英文怎麼說
中文拼音 [rèshuǐde]
熱水地
英文
hydrothermally-
Automatic cip local cleaning system is specializd equipment used for automatic cleaning for beverage production line and filling facility. acid washing, alkali washing and thermal washing can be chosen. the tempera - ture for acid, alkali and hot water can be set
自動ctp就地清洗系統,是用來對飲料生產線和灌裝設備進行自動清洗的專用設備;可提供酸洗,堿洗以及熱洗三個程序,設置酸液,堿液濃度及熱水溫度。Test and analysis on the indoor temperature gradient of low - temperature hot water floor radiant heating
低溫熱水地板輻射供暖的室內溫度豎向分佈的測試與分析Using the matlab tools, a computer program is compiled to solve this mathematic model, by which simulations to the thermal environment of the heated space under different heating style are carried out. the simulations results and their analysis show that for different space with the same thermal comfort index, the energy consumption of low - temperature water floor radiant heating system is less than that of convection heating system
基於上述採暖空間的熱網模型,運用matlab數學軟體編程,對低溫熱水地板輻射採暖方式和對流採暖方式下房間的熱環境進行動態分析,並對這兩種採暖方式下採暖系統的能耗進行計算機模擬計算,結果表明低溫熱水地板輻射採暖系統相對于對流採暖系統有顯著的節能性。A brief talk on factors that caused abnormal problems in operation of low temperature hydrothermal water floor panel irradiance heating system and solving method
淺談低溫熱水地板輻射供暖系統在實際運行中出現異常問題的因素和解決的方法Given the thermal physical parameters of the envelops and the weather data, the above two parameters are determined by the following system design parameters : radiant panel dimension, radiant panel location and radiant panel layout style ( center or peripheral ). based on the thermal net model, digital analysis of the energy consumption and thermal environment are carried out to the several representative spaces under different design parameters, through which the relations of the heating load to the design parameters are obtained and can be a reference in the practical system design
對于給定圍護結構熱物性參數和室外氣候參數的條件下,室內平均輻射溫度和室內空氣溫度的大小取決于系統的設計參數:輻射板的布置方式(周邊布置和中心布置) 、輻射板尺寸和輻射板鋪設位置。基於熱網模型,利用matlab軟體編程對採暖空間在不同設計參數下室內的熱環境和能耗進行數值分析,得出了低溫熱水地板輻射採暖系統的性能和能耗指標隨這些參數變化的規律,從而為低溫熱水地板輻射採暖系統的優化設計提供了參考。The thermal process model of imbed pipe floor heating room at intermittent operation was set up by analyzing the thermal storage of enclosure. then, a solution method was give for it basing on duhamel theorem. the calculation results shown a good indoor thermal environment can be hold when the system, which designed on out door temperature for heating basis, operates half day in night under outer door mean temperature in winter
對典型房間的計算結果顯示:系統間歇運行時,供暖系統開啟和關閉后室內溫度呈指數規律變化;當系統按供暖室外計算溫度設計,實際運行日的室外平均溫度等於供暖期室外日平均溫度時,在室外逐時溫度較低的時段低溫熱水地板輻射供暖系統運行半天左右可滿足全天供暖室內計算溫度要求。Some issues in design of the floor radiation heating system using low - temperature hot water
低溫熱水地板輻射採暖設計中的幾個問題Discussion about the household metering method referring to the floor radiant heating system using tepid water
低溫熱水地板輻射採暖系統熱計量探討4 low gas - introducing and retardation capability to meet the requirement of long - distance transportation
該系統是才用低溫熱水地面輻射技術來實現供暖。District heating - hot or cold water transport and distribution networks - regulation of the hot or cold water district heating networks
地區供熱.冷水或熱水傳輸分配網路.冷水或熱水地區加熱網路的規則Problems in applying radiant floor heating
低溫熱水地板供暖應用中的幾個問題Warm water floor heating systems and radiator pipe connecting - piping of plastic materials
熱水地板加熱系統和散熱器管道連接.塑料管道Design of low - temperature hot water floor radiant heating systems
淺談低溫熱水地板輻射供暖Low temperature hot water floor radiant heating system design in yinchuan
銀川民生城市花園低溫熱水地板輻射供暖設計Advantages and construction main points of low temperature and hot water floor radiation heating
低溫熱水地板輻射供暖的優點及施工要點Plastic piping systems for warm water floor heating systems and radiator pipe connecting - crosslinked polyethylene of medium density pe - mdx
熱水地板供熱系統用塑料管道系統和輻射管道連接,中等Being a new kind of heating style, much research has been done to the low - temperature water floor radiant heating system in its energy consumption, but which does n ' t get an unanimous result. the research in the optimization of system design is in great need to promote its using
低溫熱水地板輻射採暖系統作為一種既節能又舒適的新型採暖方式,國內外對其節能性和節能能力進行了相當多的研究,但結論不盡一致;同時對如何進行低溫熱水地板輻射採暖系統的優化設計的研究很少。The heat supply s stem of terrestrial surface radiation of low temperature hot water has been more and more widely used in architectural heat supply because of its comfort, cleanness, health care, limited size, heat stability and efficient energy - saving character
摘要低溫熱水地面輻射供暖系統由於其舒適、衛生、保健、不佔面積、熱穩定性好、高效節能等優點已越來越多地在建築供暖中得到推廣應用。Low temperature hot water floor radiant heating is a kind of energy - saving heating method which can adjust the temperature of rooms
摘要低溫熱水地板輻射供暖是一種節能並可有效調節房間小氣候的供暖方式,應用廣泛,但在工程實踐中存在較多問題。For the space heated by low - temperature water floor radiant heating system, the mean radiant temperature and air temperature are two main factors that affect the indoor thermal quality as well as the building energy consumption, so how to minimize the heating load as much as possible on the condition of securing thermal comfort demand
採暖空間的室內熱舒適度主要是由兩個因素來決定的:室內平均輻射溫度和室內空氣溫度,這兩個參數同時也影響室內採暖系統的能耗大小,因此,如何在保證室內人體熱舒適要求的條件下,最大限度地減少低溫熱水地板輻射採暖系統的能耗分享友人