  1. This paper introduces the radiographic examination procedure of the primary pump of 900mw nuclear power unit, including the requirement about the radiographic examination equipment such as the radiation sources, films, penetrameter, etc. ; the radiographic process when using the rectilinear accelerator, and the development & examination of radiographic files, defects examination and acceptance criteria, with the expectation that this introduction be useful for reference to the promotion of 1000mw nuclear power primary pump localization in china

    摘要介紹了嶺澳核電站主泵泵體製造過程中的射探傷工藝過程,包括膠片、象質計及底片的要求、加速透照工藝、底片沖洗及黑度要求以及缺陷評定和驗收標,以期我國今後百萬千瓦級主泵泵體的國產化有所裨益。
  2. The position and size of the monochromator, focusing curvature radii and tilting angles of the germanium focusing monochromator under different different take - off angle, size and divergency of the second collimator and intensity loss due to the use of it were determined. the neutron flux at different wavelength, under different reflection and take - off angle of the monochromator and divergency of the first collimator, were given. the simulation on the aperture used for limiting beam size in front of the sample showed that, smaller the size of the aperture and further the distance from the aperture to the sample, greater the loss of the intensity and more serious the spread of the beam along vertical direction at the sample position which makes the practical sampling volume greater than expected

    用蒙特卡羅模擬方法中子應力衍射譜儀的設計方案進行了優化研究,提出了一系列可供參考的數據:確定了單色的位置、尺寸、垂聚焦單色在不同起飛角下的聚焦曲率半徑和傾角;討論了第二的尺寸和發散,以及使用第二造成的強度損失;給出了在不同單色反射面、起飛角、中子波長和第一發散度的情況下樣品處的中子注量率,以及多種組合情況下譜儀的解析度曲限束方孔的尺寸、距離樣品遠近強度損失和測量中的影響做了深入研究。
  3. The online measurement of mold heat flux can not be replaced by online temperature measurement, the later can respond the uniformity of heat transfer and thickness of solidified shell mote accurately and directly, and online temperature and heat flux measurement of mold can be used to foresee the mold conditions such as fix and scaling of mold

    溫度的在檢測不能代替熱流的在檢測,後者可更確和接地反映結晶傳熱和坯殼厚度的均勻性;同時在檢測結晶的溫度和熱流有可能結晶的設備狀態(如結晶的安裝狀況和水垢狀況)實現在預測。
  4. Malfunctions can be diagnosed using infrared thermography without affecting the work state of tested equipments, thus the diagnostic accuracy can be improved. infrared thermography, just as often, improves electronic fault diagnosis by isolating the malfunction to specific areas of the circuit board, what is more, it usually does point directly to the failing component. thermography even can rapidly diagnose up to hundreds of elements on one pcb at one time, without requiring the operator to know the circuit principle very well, which can reduce the workload greatly

    紅外故障檢測儀可以電子設備進行在測量,檢測時不會影響待測設備的正常工作和頻率特性,這高頻電路的檢測尤其方便,且能提高診斷的確性;他通常能指出電路板上的故障區域,甚至經常能接找出故障元件,這樣就提高了維修質量;並且能在不需要檢測人員電路原理有深入理解和分析的情況下,同一塊電路板上的數十隻甚至數百隻件同時進行快速診斷,這就大大減少了維修人員的工作量,提高了維修人員的工作效率。
  5. At first, the author analyzed some chief factors such as light beam drift and atmospheric turbulence that affect the precision of the laser collimation in brief. then, the author studied the plan of the laser collimation generating nondiffracting beam and automatic level system with high precision. at last, the author completed the measurement of the straightness guideway by using ccd ( charge coupled device ) as the receiver and computer imaging processing

    文章首先簡要地分析了激光自身漂移、大氣湍流等影響激光精度的主要因素,然後系統的激光方案進行論證,並確定了無衍射光束的生成方案、高精度自動安平系統的結構方案,最後以ccd為接收件,通過計算機圖像處理,完成軌道性的測量。
  6. Initial recovery voltage and peak recovery voltage across the circuit - breaker have an essential affect on re - strike. for assessing performance of circuit - breaker, the higher inductance and lower inductance must be considered at the same time when testing according to theoretic analysis, the directly test circuit on switching the no - load overhead by high - voltage circuit breakers of rated voltage 252kv and below, in compliance with the correlative standard jb5871 and the test devices, and the test circuit parameters have been calculated and the many testes have been carried out

    在理論分析的基礎上,考慮實驗室現有設備的情況依據標jb5871的規定,選用合適的試驗設備,試驗路的參數進行計算,在實驗室建立了252kv及以下電壓等級斷路開合路充電電流接試驗路,利用該路進行了數臺產品的試驗,分析了試驗結果,並根據試驗結果和理論基礎討論了gb t1984 - 200 《交流高壓斷路》 (報批稿)關于開合路充電電流試驗的有關規定。
  7. That test part of the software is primarily used to complete the test of some parameters, such as time base, time - expand, time interval, voltage interval, vertical, stable state, transient state and scanning linearity. the result of the test needs to be analyzed and judged. clear user interface and timely warnings for mistakes of testing process inside because of the user ' s fault operating make whole test process more easier than it did on a time

    該軟體的測試部分主要用於完成示波掃描時間系數、擴展掃描時間系數、 t時間測量、 v電壓測量、垂偏轉系數、頻帶寬度、校信號、脈沖瞬態響應、掃描性誤差時等參數的測試檢定任務,並測試結果進行及時的分析和判斷,由於界面清晰,而且測試過程中由於用戶的誤操作都有及時的錯誤提示,使得整個測試過程簡單易行,于用戶來講掌握起來也更為方便些。
  8. The object of single photon emission computed tomography ( spect ) is to reconstruct an unknown radioactivity distribution inside the body from projection data consisting of the number of photon collected on a collimated gamma camera. these projections are not simple line integrals but have point - spreads due to the imperfect collimator of the detector and attenuation due to the compton scattering. so

    這種投影數據與透射ct中的數據不同,由於存在著光子的點擴散(由引起)和衰減(由散射引起) ,已經不能用簡單的積分來描述這個問題,因此相于透射ct而言,這個領域將面臨很多困難。
  9. Aim at the development of the software radio in generalization, standardization and modularization, a waveform synthesis solution based on direct digital frequency synthesis is developed

    國內外軟體無電技術通用、標、模塊化的硬體平臺的需求,本文提出了一種基於接數字頻率合成原理進行信號數字域調制的波形合成設計方案。
  10. A non - linear feed - forward loop is used to realize the coordinated control between the two controlled variables at the two control ends at first. secondly, a constant ac voltage control is implemented for a short period after the ac fault removal. finally, a staggered recovery strategy for different hvdc subsystems is also adopted, with the restart time interval of them optimized using the steepest descent gradient search method

    該協調恢復策略的三個特點是:在常規的控制結構中加入一個基於穩態工作點的非性前饋迴路;在交流故障被切除后的一個短暫時間內,逆變側採用定交流電壓控制:不同的流輸電子系統採取一種漸進的恢復策略。
  11. The methods of straightness measurement are mostly about a line, but the straightness of couple lasers is the mainly problem in the system. first the couple laser beams should be calibrated separately. then, the couple laser beams should be aligned, and it is the most important problem in the design

    現在度的測量方法多數是一條度進行測量,本文所要解決的主要問題是兩束激光的性校,首先要分別兩束激光性校,然後將兩束激光調到一條上,這也是設計中的重點問題。
  12. The system is mainly made of antenna seat and antenna controller. the antenna seat adopts humorous wave technique and can be directly connected with special computer and achieve numeric control, which has high resolving power of scanning and exact orientation

    該系統主要由天座和天控兩部分組成,天座採用諧波傳動技術,可接與專用計算機接,實現數字控制,掃描解析度高,定位確。
  13. The design of the laser and its bracket, neutral density filters, lens, and digital camera are complete in the hardware design ; the image collection and centroid calculation are complete in the software design ; and the experiment of straightness calibration is accomplished. the possible errors are analyzed about the whole system, and some methods to decrease the errors are put forward

    硬體部分主要完成了激光及其支架、衰減片組、透鏡組和數字相機的結構設計;軟體部分主要完成了圖像的採集和質心的求取;最後進行了性校實驗,並實驗過程進行了誤差分析,提出了減小誤差的方法。
  14. The linearity of laser beams is the guaranty of the whole system, to calibrate the linearity of laser beams is the primary problem in the paper

    而指示激光性是整個測量系統的保證,本文所要解決的主要問題就是激光性進行校