短路電阻 的英文怎麼說

中文拼音 [duǎndiàn]
短路電阻 英文
short circuit resistance
  • : Ⅰ形容詞(空間、時間兩端之間的距離小) short; brief Ⅱ動詞(缺少; 欠) lack; owe Ⅲ名詞1 (缺點) we...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • 短路 : [電學] short; short circuit; cutting out; direct short; short out; short pass短路保護(裝置) sho...
  • 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
  1. We close this chapter on resistive circuits with a brief introduction to the subject of electrical measurements.

    我們結束這一章時,簡地介紹一下氣測量問題。
  2. The development of a visual short circuit software under ptcad2000 is presented in this paper, as well as the system structure, the definition of the data structure, the interface to ptcad2000, the conversion of the original wiring diagram of power network to calculable power network, the implement of three sequence network, the implement of impendence matrix and admittance matrix of power network considering the zero sequence mutual inductances among lines, and the implement of short circuit calculation by using computer

    本文介紹了在ptcad2000平臺下流可視化計算軟體的開發。介紹了軟體的系統結構、數據結構定義、與ptcad2000平臺的介面、力系統原始接線圖轉成等值可計算網、序網的生成、考慮零序互感線抗時網導納矩陣和抗矩陣的生成,以及故障點流計算的計算機實現。
  3. For the circuit - breakers of rated voltage 252kv up, the synthetic test methods are introduced according now condition because of the limitation of the transformer short - circuit capacity. the correlative prescribes on switching line - charging current in gb / t1984 - 200x " alternating - current high - voltage circuit - breaker " are discussed according to the test results and theoretic analysis

    由於開合空載架空線試驗對源側的抗有明確的規定,這就要求試驗源必須具有足夠大的容量,實驗室很難滿足要求,因此,一般對較高壓等級的斷器採用合成試驗方法,本文介紹了利用現有條件,對252kv以上壓等級的斷器採用合成試驗時的試驗線
  4. In order to avoid gas blast because of short circuit, it should popularize shielded mine cable under coal mine. except insulated surface of part products adopting tinnint brass wires and nylon wires, its protective shield adopting conducting rubber and shielded layer which transition resistance not bigger than 3k. the protective layer adopt high machinery chloroprene rubber which is fireproof

    為防止纜相間而造成瓦斯氣體爆炸,在煤礦井下應大力推廣使用屏蔽礦用纜,除部分產品的絕緣表面採用鍍錫銅絲和尼絲交叉紡織之外,其外屏蔽型纜的保護屏蔽採用導橡皮及屏蔽層,其屏蔽層的過渡不大於
  5. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv網接地故障的形式、消弧線圈接地的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點接地方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了網接地流變化、中性點取值大小、接地點接地值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小接地方式下網的過壓水平和接地點流大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  6. For multi - infeed hvdc systems, when the minimum eigenvalue of the system becomes zero, the voltage stability graph can be plotted effective short circuit ratio as function of coupling impedance

    對于多饋入hvdc系統,在最小特徵值為零的情況下,可以根據這種關系作出有效比?連接抗圖,即壓穩定圖。
  7. Its voltage, short circuit and resistance have not linear relation. and the temperature also affects its short circuit, when the temperature is higher, the short circuit is lower. when the battery is short joined directly, there is lots of heat in the battery to make the temperature be higher

    堿錳池是一種化學源,其復雜的化學性質使得其供壓、流和內呈非線性關系,故而其流值並不滿足歐姆定律,不僅和堿錳池的開壓、內有關系,還和池溫度有關系。
  8. In accordance with the driving characteristics of ac driving locomotive, the working status of its traction transformer is analysed. the questions that should be considered in the traction transformer design of ac driving locomotive are mentioned. these questions are the large short - circuit impedance of traction winding, higher harmonic current, over - excitation and dc magnetization caused by large variation of the network voltage, etc. some disposal methods are given

    針對交流傳動力機車的傳動特點,對其中的牽引變壓器的工作狀態進行了分析,指出交流傳動力機車用牽引變壓器設計時需考慮的牽引繞組的抗大、流的高次諧波、網壓波動大可能引起的過勵磁以及直流磁化等問題,同時給出了相應的一些解決方法。
  9. So, we use a new method to measurement the battery ' s current index. we join a little resistance in the circuit, and use the loop current as the index for the shout current

    包池流的新方法:采地小池放進行流值采樣,把此小時的迴流值,作為堿錳池的一項流指標進行檢測。
  10. Thus, at zero magnetic field the metal disk acts as a short circuit ( very low resistance ), and in a strong enough field it is equivalent to an empty space ? an open circuit ( very high resistance )

    因此,沒有磁場時金屬圓盤會造成很低) ,磁場夠強時它就像空無一物的空間,成為開很高) 。
  11. For the severe limitation that the selectivity of transient current protection will lose when the fault with small resistance or without resistance takes place at the end of transmission line, the basic reason for the selectivity loss of transient current protection was investigated

    摘要針對保護出口處發生金屬性或小故障時,暫態流保護完全失去選擇性的嚴重缺陷,利用時域分析方法,進行了詳細的故障暫態分析和模擬研究。
  12. Impedance - matching balanced traction transformers ( balanced transformers in this paper for short ) are step - down transformers, they transfer symmetrical three phase voltage in primary side to perpendicular two phase voltage in secondary side. they are different from any other transformers, so their short - circuit current analysis and short - circuit test method must be taken into special account

    抗匹配平衡牽引變壓器(本文中簡稱平衡變壓器)是一種將一次側三相對稱壓變換為二次側二相垂直壓的降壓變壓器,它不同於已有的任何一種變壓器,流的分析計算和試驗必須予以重新研究。
  13. After electric heating system is installed, check electrical insulation of all circuits. the insulation resistance between generatrix and shielding layer, core wires of series cable before connection at end not be less than 20 m. and then check if dc resistance of circuit is normal and phase resistance is banlance

    伴熱系統安裝完工後,應逐檢查系統的絕緣:各種熱帶母線與屏蔽層之間、串聯帶芯線尾端末接前的各芯線間絕緣均應不小於20m ;然後再檢查熱帶直流是否正常,三相是否平衡。
  14. Research on surface and grain boundary passivation mechanism obtained effects of surface recombination on crystalline silicon solar cell performance and the theoretical expression of grain boundary recombination velocity. the limit ratio of short - circuit current increment for anti - reflection coating utilization on solar cells was obtained. the crystalline silicon solar cell spectral response, contact resistance and minority carrier lifetime measurement systems were established

    鈍化機理研究獲得了表面復合對不同表面摻雜濃度晶體硅太陽池性能的影響、表面和界面復合速度的理論表達式;研究得到了減反射膜對太陽流增量比的極限;建立了太陽池光譜響應、柵線極接觸和少子壽命等測試系統。
  15. Based on the relative theories about electric circuit and synchronous generators " post - fault transient, a practical computerized method making use of node impedance matrix is proposed to calculate the instantaneous currents of a faulty power system

    本文基於理論和發機的過渡過程理論,利用節點抗陣推導出力系統時任意時刻流的實用計算機演算法。
  16. The basic software consists of topology analysis, on - line load flow computation, state estimator, security analysis, dispatchers training simulator, short circuit current computation, and voltage / reactive power optimize, etc. the derived softwares consist of load control, capacitor optimizer configuration, transformer and feeder load distribution, impedance computation of generator, etc. network analysis software is powerful dispatch tool, though witch the current state of the power system can be realize, then improve the security and economic potential

    Dms網分析的基本軟體有:網結線分析、潮流計算、狀態估計、負荷預報、流計算、壓無功優化等。派生軟體有:負荷控制、容器優化配置、變壓器與饋線負荷分配、抗計算等。網分析軟體是有力的調度工具,通過它可以了解和掌握當前的運行狀態,從而挖掘安全和經濟方面的巨大潛力。
  17. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷器所造成的事故無論是在次數,還是在事故所造成的停時間上都占據總量60以上。因此,及時了解斷器的工作狀態對提高供可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷器機械特性參數監測方法;提出了二次迴保護器的概念,並將跳、合閘線圈完整性監視和二次迴保護結合起來,給出具有完整性監視功能的二次迴保護器實現方案;根據斷器生產廠家提供的斷器額定流分斷次數,計算每次分閘對應的觸頭壽命損耗,預測觸頭壽命;提出根據斷器殼體溫度和斷器周圍空氣溫度結合斷器熱來計算斷器主觸頭穩態溫升的方法,並根據此時的負荷流間接計算主觸頭迴;在硬體設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  18. This paper presents a novel method for short - circuit current calculation, using zero impedance branch to simulate electrical equipment ( such as circuit breaker )

    提出了將氣設備(如斷器等)用一條零抗支模擬的流計算方法。
  19. It utilizes zero impedance branch characteristic, combining structure - transform and structure - static short - circuit current calculation method to calculate the short - circuit current directly through the electrical equipment when short - circuit fault takes place at the two sides of the electrical equipment, and settles the problems that the traditional method cannot directly figure out the short - circuit current

    該方法利用零抗支特點,結合定結構和變結構流計算方法,能夠直接求出在氣設備兩側分別發生時,通過氣設備(如斷器)的流,從而合理地解決了傳統的故障分析方法不能直接求出流過設備的流的問題。
  20. The transient simulation model of impedance - matched balancing transformers is established. the effect of transient model and equivalent circuit in calculation of steady short circuit current are compared

    摘要建立了抗匹配平衡變壓器的暫態模擬模型,比較了暫態模型和等值在計算穩態流中的效果。
分享友人