磷光測定器 的英文怎麼說
中文拼音 [līnguāngcèdìngqì]
磷光測定器
英文
phosphoroscope- 磷 : 名詞[化學] phosphorus (15號元素,符號p)
- 光 : Ⅰ名詞1 (照耀在物體上、使人能看見物體的一種物質) light; ray 2 (景物) scenery 3 (光彩; 榮譽) ...
- 測 : 動詞1. (測量) survey; fathom; measure 2. (測度; 推測) conjecture; infer
- 定 : Ⅰ形容詞1 (平靜; 穩定) calm; stable 2 (已經確定的; 不改變的) fixed; settled; established Ⅱ動詞...
- 器 : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
- 測定 : determine; determination; setting-out; admeasurement; assignment; assay; finding
-
In this thesis, new fluorescence carriers with good properties were synthesized and copolymerized under uv irradiation on the silanized glass or quartz disk and - the sensors prepared were studied. ( 1 ) n - propyl - 4 - ( n - methylacryloxy - ethyl ) amino - 1, 8 - naphthalimide ( pmean ) was synthesized and used for determination of picric acid. the linear range of the sensor is 9. 80x10 - 7 - 1. 96x10 - 4 mol i - 1
( 1 )合成了n -丙基- 4 - ( n -甲基丙烯酰基氧乙基)氨基- 1 , 8 -萘酰亞胺( pmean ) ,研製出了苦味酸熒光光纖傳感器,可間接測定藥片中磷酸氯喹和水樣中苦味酸的含量。In order to compare the retention time ( rt ) and limits of detection of 20 organophosphorous insecticides in different conditions the experiments were carried out using a medium polar capillary column ( db - 1701 ) and a no polar capillary column ( db - 1 ) with two detectors ( gc - fpd and npd ). the rt of 20 organophosphorous insecticides in two different polar capillary columns was a retention qualitative method for 20 organophosphorous insecticides. db - 1701 capillary column coupled with gc - fpd detector was used in the following study, the limits of detection were in range of 5x10 - 11 ~ 2x 10 - 12 g, the linear range was 2x 10 - 9 ~ 1 x 10 - 11g
本研究用兩種檢測器(氮磷檢測器和火焰光度檢測器儀器)和兩種不同極性色譜梓(中極性毛細管色譜柱db - 1701 、非極性毛細管色譜柱db - 1 )作為研究手段,比較了20種有機磷殺蟲劑在兩種色譜柱( db - 1 、 db - 1701 ) 、兩種檢測器( fpd 、 npd )上的保留時間及最小檢測量,建立了用不同極性色譜柱上有機磷農藥的保留時間可作為有機磷農藥雙柱定性確證的的方法;建立了db - 1701 , gc - fpd測定蔬菜中20種有機磷殺蟲劑的氣相色譜法,該方法的最小檢測量為5 10 ~ ( - 11 ) 2 10 ~ ( - 12 ) g ,線性范圍在2 10 ~ ( - 9 ) 1 10 ~ ( - 11 ) g時,相關性良好。Chapter 2 in the design of sensors and switches based on photoinduced electron transfer, fluorescence was often used with high sensitivity and convenience. it is noteworthy that room temperature phosphorescence ( rtf ) has many advantages over fluorescence, e. g., large stokes shift, higher signal to noise ratio, good selectivity and easily measurable luminescence lifetimes etc., and it can be found as a helpful complementary method of fluorescence sensing
第二章在光誘導電子轉移傳感器和分子開關的設計中,熒光由於其靈敏度高、使用方便,受到人們的廣泛關注,相對于熒光室溫磷光選擇性好、信噪比高、較大的stokes位移、壽命易測定等優點,在許多方面與熒光互補。
分享友人