In this thesis, the development of emulsion polymerization theory and related new technologies are comprehensively reviewed, and the synthetic technologies of acrylate latex modified by organosilicon both at home and abroad are also reviewed. based on the current development and research in this field, attentions of this study are focused on three ways for preparing novel acrylate latexes modified by organosilicons, that is, 1 ) the acrylate monomers are copolymerized with unsaturated silicons by emulsion copolymerization ; 2 ) a new latex with microphase separation morphology is synthesized, which shows a core - shell structure character ; 3 ) soap - free polymerization is explored for preparing a higher - performance latex using an unsaturated silicon monomer, different acrylates and a reactive emulsifier. by using techniques of delaying addition of organosilicon monomer and a hydrolysis inhibitor, the hydrolysis and condensation of 3 - ( trimethoxysilyl ) propyl methacrylate during polymerization can be effectively prevented, as a result, organosilicon content in the macromolecular chain is increased
同時採用有機硅單體延遲滴加及添加水解抑制劑等技術,有效防止了-甲基丙烯酰氧基丙基三甲氧基硅烷在乳液聚合過程中的過渡水解及縮合反應,提高了聚合物大分子鏈中有機硅鏈節的含量;利用紅外光譜與差示掃描量熱儀對產物分子結構進行了表徵,並通過對共聚產物力學和吸水率的測試,證實了本研究所制備的有機硅改性丙烯酸酯共聚物具有比純丙烯酸酯聚合物更優良的力學及耐水性能;從分子設計角度出發,利用醇解反應合成出水解、縮合反應速率較慢的兩種新型不飽和有機硅單體: ?甲基丙烯酰氧基丙基三乙氧基硅烷和?甲基丙烯酰氧基丙基三異丙氧基硅烷;利用核磁共振對新型硅烷單體結構進行了證實;研究表明利用新型硅烷單體可以制備出高硅烷含量的有機硅改性丙烯酸酯乳液,且其聚合產物具有較高的力學及耐水性能。Simultaneously with the micro - displacement started the processe of the grating sensor measuring the displacement and image collection of the system. the grating sensor ( length gauge ) measures the displacement of the dial gauge with surveying rod. it is delivered to the computer with a block k220 in real time and the dial image by ccd camcorder is shown on the computer screen with the image collection card in real time
在實現微量進給的同時,啟動系統的光柵位移測量過程和圖像採集過程,光柵傳感器(長度計)測得指示表測桿的位移量,由計數卡ik220實時傳送給計算機,由ccd攝像頭攝取的表盤圖像經圖像採集卡在計算機屏幕上得以實時顯示,最後通過對指示表指針位移計算處理與光柵傳感器測量的位移量進行比較,得到指示表受檢點的示值誤差。Ultraviolet absorption detector, photodiode array detector ( dad ), fluorescence detector, and electrochemical detector are optional detectors, response value of which is relative to not only quality of the object under test, but also structure of the compound ; refractive index detector and evaporative light - scattering detector are universal detector, responding to structure of all compounds ; evaporative light - scattering detector is quality - type detector, whose responding value only relates to quality of the object under test for compounds with similiar structures ; photodiode array detector ( dad ) can, at the same time, record absorption spectra of the object under test in a prescribed wave scope, consequently, it can be used in spectrum control and inspection of purity of chromatographic peaks of the object under test
紫外、二極體陣列、熒光、電化學檢測器為選擇性檢測器,其響應值不僅與待測物的質量有關,還與化合物的結構有關;示差折光檢測器和蒸發光散射檢測器為通用型檢測器,對所有的化合物結構均有響應;蒸發光散射檢測器屬質量型檢測器,對結構類似的化合物,其響應值幾乎僅與待測物的質量有關;二極體陣列檢測器可以同時記錄待測物在規定波長范圍內的吸收光譜,故可用於待測物的光譜管制和色譜峰純度的檢查。It increases the precision of analysis to use differential spectrophotometry in high and trace contents. it has higher application value and upper popularization worth
摘要用示差分光光度法進行高含量或痕量物質的分析,使吸光度落在最佳測量范圍,增大了測量方法的精確性,具有較高的應用價值,值得推廣。Determination of flavonoids in tender stem and leaf of ampelosis prossedentata by differential spectrophotometry
差示分光光度法測定廣西瑤族藤茶中黃酮類成分的含量Study and application of determination of different content level iron by sulfosalicylic acid differential spectroscopy
磺基水楊酸差示分光光度法測定不同含量鐵的研究及應用Due to the advantages such as short response time, easy operation, and convenient to comprehend the wavefront modes, the hartmann wavefront sensor ( h - wfs ) is widely utilized nowadays in real - time adaptive optics system, turbulence statistical characterization, optical components test, light quality evaluation, laser atmosphere communication, the wavefront correction of ultrahigh power laser pulses, as well as human eye aberrations measurement. the detection accuracy is important to the performance of the whole optical system. considerable efforts have been performed in the investigation of h - wfs wavefront detection techniques in past years
哈特曼波前傳感器具有實時探測,易操作,可以直觀顯示波前畸變分佈等優點,被廣泛地用作自適應光學系統的波前信息探測和波前畸變補償,大氣湍流統計特性表徵,光學元件檢測,光束質量評價,超強激光脈沖波前整形,激光大氣通信以及人眼象差測量等各個領域之中,其探測精度的高低對整個光學系統的工作性能有著極其重要的影響。But for some special medium materials, such as liquid crystal display controller pcb, magnifiers must be used to gather images to gain enough precision of inspection for the weak contrast between the basic board and the conductor. the images near the light axes are much cleared than that far away from the light axes, so the images can not be simply segmented by black and white and inspected with the methods of pcb which are based on the black white image
但對於一些特殊介質材料,如液晶顯示控制電路板的檢測,由於基板和導體之間對比度不大,而且為了達到檢測精度,必須採用放大鏡頭進行圖像採集,成像系統光軸附近的圖像成像質量較好,而偏離光軸較遠的圖像質量較差。不能通過簡單二值化來很好地分割圖像,而已有的印刷電路板檢測方法都是建立在二值圖像進行分析的基礎上。Evaluation of uncertainty about indication error of headlamp testers for motor vehicle in measurement
機動車前照燈檢測儀發光強度示值誤差測量結果的不確定度評定Chapter six gives the comparing measurement results between this system and bm - 5 measuring crt color tv and liquid crystal tv. the reason of the measurement error will be analyzed
第六章給出了本系統與bm - 5彩色亮度計測量crt顯示器和液晶顯示器白場光色特性的對比測量結果,並對測量結果誤差的產生原因做了分析。The source of uncertainty was analyzed in detail about the determination of the epoxide index for epoxy resins by infrared spectroscopy, the determination of the temperature and the heat of the curing reaction for epoxy resins by differential scanning calorimetry, the determination of the hydroxymethyl index for phenolic resins by infrared spectroscopy and the reverse phase method of the high performance liquid chromatography for phenolic resins. the uncertainties of these testing methods were determined. some applied tests were carried out
在大量試驗研究的基礎上,首次對紅外光譜法測定環氧樹脂環氧指數試驗方法、差示掃描量熱法測定環氧樹脂反應溫度和反應熱試驗方法、紅外光譜法測定酚醛樹脂羥甲基指數試驗方法、酚醛樹脂的高效液相色譜分析方法的不確定度來源進行了分析,對測量方法的不確定度進行了評定,並進行了應用試驗。分享友人