空調工況 的英文怎麼說
中文拼音 [kōngdiàogōngkuàng]
空調工況
英文
air conditioning condition- 空 : 空Ⅰ形容詞(不包含什麼; 裏面沒有東西或沒有內容; 不切實際的) empty; hollow; void Ⅱ名詞1 (天空) s...
- 調 : Ⅰ動詞1 (配合得均勻合適) harmonize; suit well; fit in perfectly 2 (使配合得均勻合適) mix; adju...
- 工 : Ⅰ名詞1 (工人和工人階級) worker; workman; the working class 2 (工作; 生產勞動) work; labour 3 ...
- 況 : Ⅰ名詞1 (情形) condition; situation 2 (姓氏) a surname Ⅱ動詞(比方) compare Ⅲ連詞[書面語] (...
- 空調 : air-conditioning
-
Using the post processing tools of this cfd software, this article analyses the temperature and velocity field in the vav air - conditioned office and finally evaluates the indoor air distribution, adopting air diffusion performance index ( adpi )
利用cfd軟體的后處理工具對不同送風方式以及不同工況下的變風量空調室內的溫度場和速度場進行了分析,最後採用空氣分佈特性指標對空調室內的氣流組織進行了綜合評價。In this paper, the author combines the theory analysis with the experiment research method, and discusses the seismic behaviours, 3d elaborate finite element analysis and simplified model analysis of a kind of multi - function tall building - " sub - shearwall supported by frame ", which is applied widely today. the main contents are as follows : in order to observe the failure process and the earthquake response of the complex structure, and to analysis the seismic behaviour of the structural system and structural members, a 1 / 20 cement mortor model of a complex tall - building which is about to be built was producted and the shaking table test of this model under 26 sorts of earthquake loads was made. using sap2000 finite element analysis program, a 3d analysis model was built in computer, and the elastic time - history analysis of the model was done
本文採用理論分析和試驗研究相結合的方法,研究了目前應用較多的綜合性大廈? ?框支分區剪力墻高層商住樓的抗震性能及空間精細分析和簡化分析方法,主要內容為以下幾方面:對一擬建的復雜高層建築結構,採用1 20比例的空間整體模型,進行了26種工況下的模擬地震振動臺試驗,觀察了結構的破壞過程和地震反應,分析了結構及構件的抗震性能;建立了結構的精細空間模型,利用sap2000n大型有限元分析程序對結構進行了彈性時程分析;通過有限元分析與試驗結果的對比,對結構的抗震性能和抗震能力做出綜合評價,認為該結構由於轉換層上部去掉部分樓板,既可滿足建築設計的通風、採光等要求,又可達到協調結構轉換層上、下樓層抗側剛度的效果,是一種較理想的有多道抗震防線的結構型式。Studies the influence of system matching on the operation stability of automobile air conditioner compressors on the endurance test bed
摘要就系統匹配對汽車空調壓縮機耐久性試驗臺運行工況穩定性的影響進行了試驗研究。Based on the first and second laws of thermodynamics and energy level theory, analyses the primary energy ratio, exergy efficiency and energy level difference of the household gas driven air conditioner at different conditions, and compares them with some other commonly used modes
摘要運用熱力學第一定律、第二定律和能級分析理論,對戶式燃氣空調各種工況下的一次能源利用系數、 (火用)效率和能級差進行分析,並與幾種常用的方式進行對比。Then the air distribution system of the above - mentioned hotel ' s multi - function - hall was simulated with fidap, and the indoor temperature and velocity under the preliminary option was calculated. under the half - load condition of small air - supply quantity and slow velocity, finds that the problem has arisen, which the cold jets fall too fast in summer and the air distributes layer upon layer in winter
然後應用fidap對上述旅館的多功能廳空調氣流組織初步方案進行了數值模擬計算,預測了該初步方案的室內溫度、速度分佈,發現在送風量和送風速度小的半負荷工況下,會出現夏季送風時冷射流過早下降,冬季送風時氣流分層分佈的現象。Tests the operation status of an air - cooled heat pump air conditioner under defrosting conditions, and records the evaporation temperature and exhaust fan current at different voltages
摘要實驗測定了一臺空氣源熱泵空調機組除霜工況下的運行狀況,記錄了蒸發溫度和不同電壓下的排風機電流。The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method
本論文從目前空調工程中使用的變流量水系統入手,研究了盤管換熱器在部分負荷下水流量與換熱量的非線性關系,分析了文獻中介紹的旁通管通流能力選擇的不足之處和一次泵水系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵變流量水系統中壓差旁通控製法、回水溫度控製法、負荷控製法的精確性,並得出了在一次泵水系統的工況轉換時,採用負荷控製法能使冷水機組及其相應水泵在啟停時的負荷變化范圍較小,更符合建築物的冷量需求,節能效果較好的結論。There are many advantages to heat by air condition system, but there are also many problems. the air distribution of air condition room is often designed according to the summer outdoor parameters. thus, in winter, the hot air will arise with the influence of buoyancy, which result in the decline of vertical temperature gradient and produce a successive of problems
空調送風供暖有著很多的優點,但也出現了很多問題,由於空調房間的氣流組織一般是以夏季工況為設計工況,在冬季由於送風熱氣流在浮升力作用下上升,引起垂直溫度梯度的增加,並產生一系列的問題,致使空調房間冬季室內熱舒適性較差、能源利用效率較低。Puts forward an improved method based on the theory in which the enthalpy difference is considered as the driving force in heat transfer under wet cooling conditions and thinks that the method can halve the testing work, require less for the experiment devices and reach higher accuracy
認為該方法遵循了焓差是濕工況下換熱推動力的規律,試驗工作量減少一半以上,對試驗裝置的要求降低,由試驗數據整理出的公式用於表冷器熱力計算完全可以滿足空調常用范圍內的要求。Adopt zoning the different air - conditioning operating mode, adjusting the fresh air ratio in different zone to the optimal, at last getting out the energy efficiency effect by changing fresh air ratio
根據空調工況的分區原則,在不同的區域內進行新風量的最佳調節,從而計算變新風比的節能性。Abstract : based on deeply investigation of evaporative cooling application condition in northwest china, the main problem existed in present application is analysed, and the improvement ways and research directions is put forward later
文摘:在深入調查研究蒸發冷卻技術在中國西北地區空調工程中應用狀況的基礎上,系統分析了目前應用中所存在的主要問題,並提出了今後的改進措施和研究方向The experiment took water as the medium and experiments on two jet modes were carried out under the falling film vacuum evaporating. the experimental results indicated that the two ejectors in series compensation method could adjust the variational work situation due to the decrease of primary steam or secondary steam and insure the normal production. at the same time, the ejector ' s best work situation founded in the experiment would provide reference for ejector ' s design and usage
本實驗建立了一套降膜真空蒸發裝置,以水為介質,對變工況下單級和串聯噴射熱泵蒸發進行了實驗,結果表明兩級串聯補償噴射裝置能對由引射蒸汽和工組蒸汽壓力降低所造成的混合蒸汽壓力降低進行調節,達到了變工況下正常生產的目的。It is indicated that hrv has many advantages certified by theoretic analyze and engineering practices, such as fully ventilating, abundant fresh air supplying, energy saving, etc. comparing with independent fresh air supplying, hrv is supposed to cause potential problems, - in summer load of fan - coil units will be increased, and the wet operating mode will be aggravated, the indoor relative humidity will be increased
新風換氣機供應新風是住宅空調系統較為理想的新風供應方式,本文通過理論計算及工程實踐表明採用,新風換氣機具有換氣充分、新風量保證、節能等優點。但與新風機組獨立供應新風相比,新風換氣機供應空調系統新風時,會造成夏季風機盤管負荷增加,濕工況加重,室內相對濕度有增加趨勢。This will appeal to engineer in the design process of the public building air condition system, satisfied the room function request, at the same time, proceeding sound attenuation sound absorption design of the air condition system reasonably. according to the noise of air - condition system and the pipe regenerative noise, compute demanded sound deadening capacity. designing and choosing the right type and equally outline measures
目前,在建築設計過程中通常首先計算空調設備運行時產生的設備噪聲以及空調管道工作時產生的再生噪聲;然後根據建築設計手冊中相應的噪聲允許值的規定計算出系統所必需的消聲量;最後根據空調系統的實際情況,科學地確定適宜的消聲器類型和規格,以此達到使用空間的噪聲要求。In september 2001, the department arranged with the electrical and mechanical services department emsd to adjust the fresh air intake and air balance of its air conditioning and ventilation systems in the revenue tower
2001年9月,機電工程署為本局籌劃改善稅務大樓的空調和抽風系統,調節新鮮空氣的進氣量和空氣平衡狀況。Clean air conditioner design used in clean eorkshop for one final packing rest
客車空調機組性能試驗臺室外側工況參數的模糊控制The author deems that the using of the gehp in northeast area of china should using gas boiler for assistant heating up, moreover, the operating mode should in alternation manner. in yellow river valley the gehp should be designed in heating mode, but in yangtze river valley we should take air conditioning mode
認為機組在東北地區應採用燃氣鍋爐進行輔助加熱,並採用交替運行方式;在黃河流域應用應按供熱工況設計;在長江流域應用應按空調工況設計;在華南地區應用則可以緩解夏季電力緊張。Air conditioning condition
空調工作狀況The investigation in some locomotive crew shows that the diesel locomotive runs freely and with part load in the most part of time ; the expense of fuel nearly accounts for 65 to 70 percent of the whole expense of all locomotive crews
本文對機務部門進行的調查表明:機車柴油機大部分時間工作在部分負荷和空轉工況;燃油費用占機務部門生產成本的65 70 。The status of indoor airflow, especially the air distribution of great space, is an important issue in heating, ventilating, and air conditioning engineering
室內氣流流動狀況,特別是高大空間的氣流組織,是採暖、通風及空調工程中的一個重要問題。分享友人