紅外光度法 的英文怎麼說

中文拼音 [hóngwàiguāng]
紅外光度法 英文
infrared photometric method
  • : 紅Ⅰ形容詞1 (像鮮血或石榴花的顏色) red 2 (象徵順利、成功或受人重視、歡迎) symbol of success lu...
  • : Ⅰ名詞1 (外面) outside; external side 2 (外國) foreign country 3 (以外) besides; beyond; in ...
  • : Ⅰ名詞1 (照耀在物體上、使人能看見物體的一種物質) light; ray 2 (景物) scenery 3 (光彩; 榮譽) ...
  • : 度動詞[書面語] (推測; 估計) surmise; estimate
  • : Ⅰ名詞1 (由國家制定或認可的行為規則的總稱) law 2 (方法; 方式) way; method; mode; means 3 (標...
  • 紅外 : infrared紅外報警裝置 infrared warning device; 紅外測雹 infrared detection of hail; 紅外測繪 infra...
  1. In this thesis, the oxygen sensitive materials and glucose sensitive materials had been developed by thermo - polymerization method including carrier covalence method and carrier covalence - cross linking method, and the properties had been investigated using the detection experiment of oxygen and spectrophotometer, at the mean time, the applications of oxygen sensitive materials in fiber optical gaseous oxygen sensor and fiber optical dis solved oxygen sensor, and that of biology sensitive materials in fiber optical dextrose sensor had been studied in this paper. major content of this work includes five aspects as follows : ( 1 ). oxygen sensitive materials had been prepared by carrier covalence method, and the preparation mechanism of the materials had been investigated by fi - ir, sem, and the detection experiment of oxygen

    本論文主要包括以下五個方面的內容: ( 1 )載體共價制備氧敏感材料:通過譜、掃描電鏡圖譜和氧測試實驗探討該氧敏感材料的制備機理,通過氧測試實驗評價該氧敏感材料的氧敏感性和穩定性,同時研究了各種因素對該氧敏感材料性能的影響( 2 )載體共價?交聯制備氧敏感材料:通過譜、掃描電鏡圖譜和氧測試實驗探討該氧敏感材料的制備機理,通過氧測試實驗和分計評價該氧敏感材料的氧敏感性和穩定性,同時研究了各種因素對該氧敏感材料性能的影響( 3 )氧敏感材料在纖氣態氧傳感器中的應用:該傳感器的響應時間為10s ,檢測下限為5ppm ,檢測精為0 . 5 ,具有較好的重復性和穩定性,遲滯較小,使用壽命至少為1年,適合各種環境下氣態氧濃的檢測。
  2. Water quality - determination of petroleum oil, animal and vegetable oils - infrared photometric method

    水質石油類和動植物油的測定紅外光度法
  3. There is many a method to measure oil concentration, but the commonly used one is infrared absorbance luminosity method, so firstly the article illustrates fundamental of absorbance luminosity method for quantitative analysis - lambert beer law, and puts up with the basic model for system measurement, and then designs measure logic of system

    關於水中油含量的檢測有多種方,最常用的是,本文對吸在物質定量分析中的基本理論? ? lambert - beer定律做了簡要介紹,並以此提出了系統測量的基本模型,進而設計了系統的測量邏輯。
  4. At first, the principle and technique employed in transmittance oxymetry is analyzed. the lambert - beer law and the difference in extinction coefficient of components in tissues relate to different light wavelength is applicable in reflectance oximetry as well as in transmittance oximetry, as both are relate to near - infrared spectroscopy

    本文在深入了解透射式血氧飽和測定原理及其方之後,首先明確用近測定組織血氧飽和時,無論是透射式檢測手段還是反射式檢測,其依據的基本原理都是lambert - beer定律和組織中各成分對應不同波長的吸收系數的差異。
  5. The conventional methods of the gemmology and the modern instruments of electronic probe, ultraviolet - visible spectrophotometer, fourier transform infrared spectrometer, cathodoluminescence spectrometer are used to research and analyse the flux - grown synthetic spinel and compare them with the natural spinels

    摘要採用常規的寶石學研究方以及電子探針、紫可見分計、傅里葉變換譜儀和寶石陰極發譜儀等現代測試儀器,對助熔劑合成尖晶石的寶石學特徵進行了全面分析,並與天然尖晶石進行了對比。
  6. By contrasting the dimension and appearance of fe of different precursors, verified it is true that the dimension and appearance of precursor affect these facets of fe. modern measures, for instance xrd, tem, sem, laser and infrared technique etc. are used to research the technique indexes of sfp of fe, such as crystalline, dimensions and its distribution, shape and appearance, assemble status and its oxygen content

    對所制備的超微fe粉,採用x射線衍射( xrd ) 、透射電鏡( tem ) 、掃描電鏡( sem ) 、激衍射粒分佈測定以及測氧等現代分析測試手段,詳細考察了超微fe粉的晶態、尺寸、粒分佈、形貌與團聚狀態、氧含量等多項技術指標。
  7. The interface behavior between essence and ethylene - vinyl acetate copolymer pallets was studied so that necessary data were obtained to guide the preparation of fragrant masterbatch. the adsorption type and wettability between essence and the copolymer pallets were analysed by measurements of fourier transform infrared spectrum, surface tension, contact angle and specific surface area. the technical factors affecting absorptivity such as the charge ratio, temperature, pressure and stirring speed were studied by series of adsorption experiments. the results showed that the adsorption of essence on the surface of ethylene - vinyl acetate copolymer pallets is physical in nature. essence couldn ' t moisten the surface of ethylene - vinyl acetate copolymer pallets absolutely, but it could be soaked into the surface of the pallets partly. adsorptivity could be increased by enhancing the temperature, pressure and stirring speed, but the extension of adsorption time had little influence on adsorptivity

    研究了香精與乙烯/醋酸乙烯共聚物粒子之間的界面行為,以便為香型母粒的制備提供必要的理論依據.利用傅立葉變換譜、表面張力、接觸角及比表面面積等測定手段,分析了香精與載體之間的吸附類型和潤濕作用.並通過一系列吸附實驗,討論了配料比、溫、壓力、攪拌等工藝條件對吸附量的影響.結果表明,香精在乙烯/醋酸乙烯共聚物粒子表面的吸附為物理吸附;香精無完全潤濕載體粒子表面,但可以對其形成部分浸潤;提高溫、壓力、攪拌速可以增加吸附量,而延長吸附時間對增加吸附量貢獻不大
  8. Abstract : the interface behavior between essence and ethylene - vinyl acetate copolymer pallets was studied so that necessary data were obtained to guide the preparation of fragrant masterbatch. the adsorption type and wettability between essence and the copolymer pallets were analysed by measurements of fourier transform infrared spectrum, surface tension, contact angle and specific surface area. the technical factors affecting absorptivity such as the charge ratio, temperature, pressure and stirring speed were studied by series of adsorption experiments. the results showed that the adsorption of essence on the surface of ethylene - vinyl acetate copolymer pallets is physical in nature. essence couldn ' t moisten the surface of ethylene - vinyl acetate copolymer pallets absolutely, but it could be soaked into the surface of the pallets partly. adsorptivity could be increased by enhancing the temperature, pressure and stirring speed, but the extension of adsorption time had little influence on adsorptivity

    文摘:研究了香精與乙烯/醋酸乙烯共聚物粒子之間的界面行為,以便為香型母粒的制備提供必要的理論依據.利用傅立葉變換譜、表面張力、接觸角及比表面面積等測定手段,分析了香精與載體之間的吸附類型和潤濕作用.並通過一系列吸附實驗,討論了配料比、溫、壓力、攪拌等工藝條件對吸附量的影響.結果表明,香精在乙烯/醋酸乙烯共聚物粒子表面的吸附為物理吸附;香精無完全潤濕載體粒子表面,但可以對其形成部分浸潤;提高溫、壓力、攪拌速可以增加吸附量,而延長吸附時間對增加吸附量貢獻不大
  9. The method is developing and the data is accumulated through the analysis of the glucose near - infrared spectrum

    對血清中葡萄糖濃做近譜分析可以探索實驗方,積累實驗數據。
  10. In this paper, the property difference of sio2 sols used for preparing thin films by esam method or sol - gel process has been discussed. three kinds of sio2 sols were prepared, catalyzed by hcl or nh3 h2o only, or hcl first and then nh3 h2o respectively ( please note : in following text, the sio2 sol catalyzed by hc1 first and then nh3 h2o and its correspondent films will be named sio2 sol 1 # and film 1 ; the sio2 sol catalyzed by nh3 h2o only and its correspondent films will be named sio2 sol 2 # and film 2 # ). through investigating the assembling properties of the sols, observing thin films " microscopic structure with tem and testing their transmissivity with 721 spectrophotometer, we find that the first kind of sol is not suitable for preparing esam films, but the last two, i. e. sol 1 # and sol 2 #, are good

    本文討論了esam制備薄膜所用的溶膠與sol - gel所用的溶膠在性能上的區別,在hc1或nh _ ? h _ 2o分別單獨催化和hc1 nh _ 3 ? h _ 2o分步催化三種催化條件下制備了sio _ 2溶膠(以下規定hc1 nh _ 3 ? h _ 2o分步催化的sio _ 2溶膠為1 ~ #溶膠,相應的薄膜為1 ~ #薄膜, nh _ 3 ? h _ 2o催化的sio _ 2溶膠為2 ~ #溶膠、相應的薄膜為2 ~ #薄膜) ,在通過組裝薄膜並用透射電鏡( tem )觀察薄膜微觀結構以及用721分計測試樣品的透射率,得出了后兩種催化方所制備的溶膠適合於esam鍍膜,而第一種溶膠不適于用此鍍膜的結論,用傅立葉譜( ft - ir )研究了溶膠組成;用差熱失重分析儀( dta - tg )對膠體進行了熱分析。
  11. Using the eye - gaze distinguishing and tracking method based on the image processing technique, the position relationship between pupil center and glint which produced by the corneal reflection and the near - infrared light was analyzed, the fixation point of the eye - gaze on display screen was deduced, and the mouse accuracy by eye - controlled in the screen may achieve to 40 pixels

    摘要利用基於圖像處理技術的視線方向識別、跟蹤方,通過近線在眼睛角膜反射產生的斑和瞳孔中心的位置關系來確定視線方向,推導出人眼在計算機屏幕上的注視點,進而實現人眼對鼠標的定位與操作,其在顯示屏上定位精可達到40 40像素。
  12. Abstract : how to analyze oil in sediment by infrared photometric method and preferably solve the problem of standard oil is described ; the feasibility of ip method is discussed and the experiment results is presented

    文摘:運用測定沉積物樣品中油類,較好地解決了標準油品的問題;探討了該方的可行性並總結了實驗結果。
  13. Based on the specialization of infrared optical system loading in missile, it proved that optical passive athermalisation technique is a wise choice

    根據彈載學系統工作的特殊性,採用學被動消熱方進行實例設計,得出了在? 30 ~ 50范圍內實現環境溫補償的系統設計參數和評價結果。
  14. The effect on optical system caused by environmental temperature variation and several typical athermalisation techniques as well as theirs ' advantages and disadvantages were presented in this paper

    摘要環境溫的變化對學系統的影響很大,針對此類問題,分析了國內典型的消熱方,比較其優缺點。
  15. Graphically - oriented local multivariate calibration modeling procedures called interval partial least - squares ( ipls ) was applied to select the efficient spectral regions that provided the lowest prediction error

    本研究提出一種間隔偏最小二乘的農產品近譜譜區選擇方,並將其應用於建立蘋果糖譜模型。
  16. Standard test method for determination of low levels of water in liquid chlorine by on - line infrared spectrophotometry

    在線測定液氯中水的低等級的標準試驗方
  17. Evaluation of uncertainty for determination of oxygen in copper - chromium alloy by pulse fusion - infrared spectrometry

    脈沖熔融測量銅鉻合金中氧含量的不確定評定
  18. The source of uncertainty was analyzed in detail about the determination of the epoxide index for epoxy resins by infrared spectroscopy, the determination of the temperature and the heat of the curing reaction for epoxy resins by differential scanning calorimetry, the determination of the hydroxymethyl index for phenolic resins by infrared spectroscopy and the reverse phase method of the high performance liquid chromatography for phenolic resins. the uncertainties of these testing methods were determined. some applied tests were carried out

    在大量試驗研究的基礎上,首次對測定環氧樹脂環氧指數試驗方、差示掃描量熱測定環氧樹脂反應溫和反應熱試驗方測定酚醛樹脂羥甲基指數試驗方、酚醛樹脂的高效液相色譜分析方的不確定來源進行了分析,對測量方的不確定進行了評定,並進行了應用試驗。
  19. Infrared photometric method

    紅外光度法
  20. Analysis of water used in boiler and cooling system - determination of mineral oil - infrared photometric method

    鍋爐用水和冷卻水分析方油的測定紅外光度法
分享友人