線弧接點 的英文怎麼說

中文拼音 [xiànjiēdiǎn]
線弧接點 英文
zero level bank contact
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 名詞1. [數學] (圓周的任意一段) arc2. (古代指弓) bow
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ名詞1 (液體的小滴) drop (of liquid) 2 (細小的痕跡) spot; dot; speck 3 (漢字的筆畫「、」)...
  • 接點 : (接觸點; 連接點) contact; closing; junction; connection point; terminal pad接點電阻 contact resistance
  1. By this solution, a balde body model can be created by the optimization of the parametric grid of the blade body surface. some key techniques used in the solution, such as the computation of the data points on the meanline, the technology of cotinuty between the leading line and the outline of the blade body and the technology of the cross - section curve discretization, are disserated, and corresponding algorithm are presented in this paper

    在進行參數網格優化的過程中,需要進行中數據求解、緣頭拼和截面離散,本文對以上三個問題進行了深入研究,並在此基礎上提出了中數據求解演算法,緣頭拼演算法和截面離散演算法等研究成果。
  2. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議主要是在10kv電網地故障的形式、消地的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性地方式的選擇問題進行研究。論文首先對10kv電網的中性運行各種方式進行分析,比較各方式的特,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網地電容電流變化、中性電阻取值大小、地電阻值變化等多種影響因素的情況下,對中性經消地和經小電阻地方式下電網的過電壓水平和短路電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  3. Moreover, the epiipc functions properly and stably under well due to the reasonable electrical circuit design and very strong anti - jamming design. this design successfully solves the directionally power current leakage fault action and reject action, and makes it working in both neutral point non - grounded and grounded through resistors or coils under compensate systems and over compensate systems

    本次研製的保護器較好地解決了功率方向型漏電的誤動作和拒動作問題,使得它既能較好地運行在中性地的系統中,又能用在中性經消地的欠補償系統中,同時試用於過補償系統中。
  4. Arc - grounding fault line selection is the paper ' s key point and innovative point about small current grounding power systems. a lot of simulations are made based on the change rule and the character of fault voltage, fault current. the simulation study declare that the use of the method of wavelet analysis can select the fault line when the arc - grounding fault take place, it will play a important directive role in the research of the protection equipment

    對小電流地系統電故障的選模擬是本文的重,也是一個創新,本文從研究的角度,在深入分析電地時故障電壓、電流的特和變化情況的基礎上,進行了大量的選模擬,模擬表明電故障時,小波分析方法也能準確地選出故障路,這對研製高性能的地保護裝置將起到重要的指導作用。
  5. China ’ s 10kv distribution systems are almost grounded via the arc - suppression coil or not grounded systems

    我國10kv配電網大部分是中性經消地系統或者中性地系統。
  6. In mode selection of middle and large capacity units nowadays, there mainly have two types of peterson coil grounding and distribution transformer with resistor

    在現有大中型發電機中性地選擇上,主要有消地方式和地變高阻地方式。
  7. It builds a relative coordinates based on the jumping - off point of circular interpolation as its origin, caculates the sine and cosine of the angle formed by x axis and the line which connects the origin and the centre of the circle, then gets the coordinates of the centre in the relative coordinates, and enduces a uniform fomula, which is easy to program in computer

    摘要用圓插補起作為相對坐標系原,連和圓心,求出該連和相對坐標x軸的夾角的正餘弦值,由此解出圓心在相對坐標系的坐標,並得到一個統一的計算公式,易於計算機編程實現。
  8. It has been proved by test results that this protective method is suitable not only for neutral point insulated system, but also for neutral point grounded system through arc suppression coil

    實驗結果表明:該保護原理不僅適用於中性絕緣的供電系統,而且適用於中性經消地的供電系統,提高了選擇性漏電的動作可靠性,保證了動作值的穩定性。
  9. It depends on many factors. in our country, middle and low voltage distribute net system uses non - direct - grounded system including no - grounded system and anti - arc system

    我國中低壓配電網多採用小電流地系統,即中性地或者經消地。
  10. After the neutral point is grounded through perterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc

    中性經消地后,有效減小了流過故障的電容電流,減小了地過電壓,有利於電熄滅。
  11. After the neutral point is grounded through peterson coil, it can decrease the capacitor current through fault point and the over - voltage caused by the grounding fault, which is advantage for the extinguishments of electric arc

    中性經消地后,有效地減小了流過故障的電容電流,減小了地過電壓,有利於電熄滅。
  12. The thesis analyses some kinds of representative grounding devices with automatic resonance petersen coil and points out their characteristics and applicability separately

    =本文分析了國內外具有代表性的幾種自動調諧消地裝置,分別指出了它們的特和適用條件。
  13. To solve these problems, the compensating method of neutral point grounding through peterson coil is commonly used in our country

    為了解決這一問題,我國現在普遍採用中性經消地的補償方式。
  14. In china, neutral isolated and peterson coil grounded system are widely used in 6 kv ~ 35kv medium voltage distribution networks

    我國大多數6 35kv中壓配電網均採用中性地或經消地的運行方式。
  15. Finally, system ’ s measurement error and error compensation method are analyzed, and some measures of anti - interference are taken to improve system ’ s reliability. the project was finished by combination the theory and the practice, and a new way on peterson coil automatic compensation is available

    本課題將理論運用和實踐相結合,為中性經消地系統的自動調諧提供了一種新的技術手段,具有廣闊的應用前景。
  16. In recent years, with the large - scale reconstruction of city power system, the scale of power system is continuously expanding, and the power supply network is becoming larger and larger. in addition, the enormous use of cables in city power system increases the current through the grounded capacitor. these lead to more and more instantaneously grounding faults unable to eliminate naturally

    近年來,國家對城市電網的大規模改造,使得電網的規模不斷發展,配電網路越來越大,加上城網中大量使用電纜,使地電容電流大大增加,越來越多的瞬間單相地故障不能自動消除,為了解決這一問題,我國普遍採用中性經消地的補償方式。
  17. According to the present actual underground power system which neutral point is grounded through arc suppression coil in many supper big shaft, the development history and present situation of synthetic protection system used in hv flameproof switchgear are reviewed, and on the basis of analyzing the problems existed in high voltage flameproof switchgear, the selective leakage protective method based on the detecting harmonic direction of zero sequence current as well as the value of zero sequence voltage is proposed in this paper, and at the same time, harmonics extracting schematic and transforming circuit are also designed

    本文深入系統地研究了基於intel80c196kb單片機控制的6kv防爆開關綜合保護系統,主要內容如下:針對大型及特大型礦井供電系統中性普遍採用消地方式的現狀,回顧了國內外礦用高壓防爆開關保護系統的發展歷史,分析了目前國內高壓饋電開關保護系統所存在的問題,提出了「基於零序電壓基波啟動,五次諧波功率方向比較」的選擇性漏電保護原理,設計了相應的五次諧波提取電路和功率方向鑒別電路。
  18. The small current neutral grounding system is a kind of system without neutral grounding, in most of which the neutral point connects to ground through a reactor

    小電流地系統是指中性不直地系統,其中大多數採用中性經消地方式。
  19. And this paper structures the emulation model of 10kv transformer substation by utilizing matlab toolbox, emulations the fault course when single - phase ground fault occurs in the small current earth system. and validates the validity of the " gradual identifying law "

    並利用matlab工具箱構建10kv變電站模擬模型,對中性地和經消地系統在不同故障情況下的故障過程進行了模擬,進而驗證了「遞進信息法」的正確性。
  20. Association with the situation of china, the solution is grounding the neuter point by peterson coil which will decrease the fault current and improve the human security. but it also brings two problems : first, the improper compensation will cause over voltage ; second, it ’ s hard to fault select

    但是,中性經消地后存在兩方面的問題:首先,消圈調諧不當易產生諧振過電壓;其次,在中性經消地系統中,發生單相地時故障選困難。
分享友人