線弧電纜 的英文怎麼說

中文拼音 [xiàndiàn]
線弧電纜 英文
bank cable
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 名詞1. [數學] (圓周的任意一段) arc2. (古代指弓) bow
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ名1. (拴船用的鐵索或多股粗繩) cable; hawser; mooring rope 2. (擰成多股的似纜物) thick rope; cable Ⅱ動詞(用繩索拴船) cable
  • 電纜 : cable; electric cable
  1. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv網接地故障的形式、消圈接地的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以為主的城區10kv網中性點接地方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了網接地流變化、中性點阻取值大小、接地點接地阻值變化等多種影響因素的情況下,對中性點經消圈接地和經小阻接地方式下網的過壓水平和接地點短路流大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  2. Along with the development of power network transmissed in our country, the internal electric power net in industry and enterprise and the electric power sesytem on generating electricity and power supply, the overvoltage phenomena in the electric power sesytem becomes more and more serious

    隨著我國網系統的發展,力系統中的過壓現象越來越嚴重,尤其隨著路逐漸代替架空路,流不斷增加,光接地現象更是不可避免。
  3. The cable is manufactured on argon arc welding, crrugating and slotting production lind with the most advanced technolongy byslotting the holes along outer conductor axis, so the evenly - distributed rdlatively strong radiating signal in the close vicinty lf the cable along ts axis make it possible signal transimission, across long distance in uncovered area

    50歐姆漏泄同軸系採用現今最先進的氬焊、軋紋和可多向開槽設備,切削一組合適的外導體槽孔,使周圍沿信號傳輸方向具有強度相對均勻的射頻信號,實現信號在分立天盲區的長距離輸送。
  4. In recent years, with the large - scale reconstruction of city power system, the scale of power system is continuously expanding, and the power supply network is becoming larger and larger. in addition, the enormous use of cables in city power system increases the current through the grounded capacitor. these lead to more and more instantaneously grounding faults unable to eliminate naturally

    近年來,國家對城市網的大規模改造,使得網的規模不斷發展,配網路越來越大,加上城網中大量使用,使接地流大大增加,越來越多的瞬間單相接地故障不能自動消除,為了解決這一問題,我國普遍採用中性點經消圈接地的補償方式。
分享友人