線性故障 的英文怎麼說

中文拼音 [xiànxìngzhàng]
線性故障 英文
linearity failure
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : Ⅰ名詞1 (性格) nature; character; disposition 2 (性能; 性質) property; quality 3 (性別) sex ...
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • 線性 : [數學] [物理學] linear; linearity線性代數 linear algebra; 線性方程 linear equation; 線性規劃 line...
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  1. The system regards the analyzing of deliquescent gas in oil as main method for diagnosing inner delitescent fault. the system carries out a comprehensive diagnosing combined with diversified high voltage tests items and it can identify the sort of fault. this method effectively remedies the limitation of single means

    該系統以油中溶解氣體分析作為診斷內部潛伏的主,結合各種相應的高壓試驗項目進行綜合診斷,確定的類別,有效地彌補了單一方法的不足。
  2. Because of the elements which run under nonideal linearity and unentire symmetry in the power system, the loads which are different and change randomly, the methods which adjust and control the system faultily and operate improperly, the disturbance and the malfunction which happen somewhere, the current and voltage in the supply system are distorted seriously and thus large amount of harmonics are produced

    但是,由於電力系統元件運行的非理想或非完全對稱、負載的質各異且隨機變化、調控手段的不完善以及錯誤操作、外來干擾和各種的存在,供電網中的電流(電壓)發生畸變,產生大量諧波。
  3. On - line fault diagnosis for high - power power electronics equipments is a significative subject. it is an intersectional subject that has been come into being in order to adapt to the engineering demand

    電力電子裝置在診斷是一個具有重要意義的課題,它是適應工程實際需要而形成的一門交叉的綜合學科。
  4. The fractal theory application to fault diagnosis is tried in order to overcome the defec t of wavelet transform to nonlinear signal analysis and complicated machine diagnosis, including the concept, function and application about fractal dimension and the process of applying it to analyze the libration signal of rolling bearing and engine burning

    針對小波變換分析復雜非機械繫統時表現出的力不從心,又嘗試探討了分形理論在診斷領域中的應用,討論了分形維數的概念、物理意義和應用,並通過滾動軸承和發動機燃燒振動信號的分析例示探討和展示了應用分形方法進行診斷的方法和過程。
  5. In this paper, the rotating machinery at high speed is studied. there are discussed about numerical calculating methods for non - linear dynamical system, the rotor system radial impact and rubbing dynamics behavior analysis having the nonlinear rigidity on the unsteady and non - linear oil film, the rotor system dynamics behavior analysis with bending - torsional - pendular coupling vibrations, application of wavelet, fractal and network in fault diagnosis. the main works in this paper are as follows : ( 1 )

    本文以高速旋轉機械為主要研究對象,系統、深入地研究了非動力學系統的數值計算方法、具有非剛度的轉子系統在非穩態非油膜力作用下的徑向碰摩動力學行為、轉子彎扭擺耦合振動的動力學分析、小波和分形理論及人工神經網路在診斷中的應用問題。
  6. In the part of detector, it mainly introduces the design of liquor tubes, heater, pressurize, and thermocouple ; in the part of controller, this design uses tms320lf2407 as the cpu. the design part mainly introduces controller circuit design which mainly contains data collection circuit, prepositive magnifying circuit, a / d convert circuit, failure self - diagnosis circuit, the tms320lf2407 interface circuit, temperature control circuit, display circuit, 4 ~ 20ma standard signal output circuit ; in the software part, it mainly introduces software chart of main program and partly linearization subprogram design

    檢測器部分重點介紹了導流管的設計、加熱器的設計、密封技術的設計以及測溫電路的設計;控制器部分以tms320lf2407為核心,重點介紹了控制器電路設計,主要包括數據選擇電路、前置放大電路、 a / d轉換電路、自診斷電路、 tms320lf2407介面電路、控溫電路、顯示電路、 4 20ma標準信號輸出電路共八個部分;軟體設計重點介紹了主程序軟體設計及分段化子程序設計。
  7. According to the quickly adjustable characteristic of the peterson coil grounding system, this dissertation proposes a new control strategy. when the system is in operation, the strategy can limit the series resonance over - voltage by using the off - resonance method. when fault occurs, the strategy can conveniently suppressing arc by rapidly adjusting the inductance value of the peterson coil to the point, which the resonance with grounding capacitance of the power network is occurred

    依據可控硅控制消弧圈接地系統的快速可控,一改傳統的電網正常運行時調節消弧圈接近於全補償的預調諧方法,提出正常運行時採用脫諧方法抑制串聯諧振過電壓;時立即調節消弧圈電感量達到與對地電容諧振,以利熄弧的新型調節原理和方法。
  8. At last, the the feasibility and validity of monitor and diagnose on - line ' s system of early hider faults is demonstrated in practical examples

    最後,本文以實例說明在監測和診斷系統對早期潛伏作出預診判斷的可行和正確率。
  9. A new intelligent on - line method for obtaining the optimal reclosing time of transient faults is presented and verified and satisfies the need of real - time

    提出並驗證了瞬時最佳重合時刻的智能式在捕捉新方法,滿足實時需要。
  10. Conventional automatic reclosing " s shortcoming is that it acts blindly entirely before reclosing and cannot distinguish instantaneous fault from permanent fault

    傳統的單相自動重合閘的缺點是在重合閘之前,完全是盲目的動作,無法區分路發生的是瞬時還是永久
  11. The software system of smart spaces distinguishs ifself from traditional distributed systems in that : 1 ) they should deliver functionality in our everyday world, which is a complex and dynamic changing environment ; 2 ) the system will consist of many wireless networked devices, while wireless connection is prone to transient failure ; 3 ) the interaction points for the people are distributed and multimodal, which imposes tight temporal constraints on the messaging between related modules ; 4 ) modules coming from diversified domains need to cooperate, which raise the need for an abstraction model at a proper level for the construction of the system

    智能空間系統具有區別于傳統分散式系統的新特徵: 1 )背景環境是復雜、動態的物理空間,新的模塊可能隨時進入和離開; 2 )存在大量無聯網設備,而無網的一個典型特徵是暫時頻繁; 3 )系統的交互點是分佈和多模態的,相關的模塊間消息的時間關系要求嚴格; 4 )各種不同應用領域的模塊都可能需要交互協作,同時需要考慮對遺留代碼的包容
  12. In order to avoid the ehv system disaster caused by reclosing on the permanent fault of transmission line, adaptive autoreclosure based on microprocessor - based protection arises at the historic moment, but is still in the stage of theory study

    為了避免超高壓輸電路採用自動重合閘時重合於永久所造成系統穩定破壞等重大系統災難,在微機保護的基礎上,自適應重合閘應運而生,但尚處于理論探索階段。
  13. On the basis of extensive reading and research of theory of the wavelet, it is presented a practical method based on odd theory of wavelet analysis to remove the white noises from transient fault current traveling waves of high voltage transmission line via multi - size analysis of wavelet

    本文在廣泛閱讀和深入研究小波理論的基礎上,論文提出了一種基於小波分析的奇異理論對通過小波多尺度變換的高壓輸電電流暫態行波信號進行白噪聲濾除的實用方法。
  14. The dissolve gas analysis method which adopted widely at home and abroad is used as dominant idea to diagnose internal incipient fault. synthetical diagnosis on the basis of combining all kinds of relevant tests make a decision for the fault position. tests include routine test for oil and preventive test for transformer

    該系統以國內外公認的油中溶解氣體分析作為診斷內部潛伏的主,結合各種相應的試驗項目(預防試驗、油務試驗等)進行綜合診斷,確定的大體部位。
  15. Using distributed architecture, this controller integrates functions of protection, metering, signaling, communication and new kind of distribution automation. it combines the function for integrated automation and feeder automation. so this product can be used not only in the reforming of substation, realizing the protection of equipments and power lines, but also in ring power network, through repetitious reclose, eliminating instantaneous faults and isolating permanent faults

    本文所研究的智能重合控制器採取戶外分散式結構,將保護和測量、控制、信號、通訊以及新型配電自動化等功能集成一體;與斷路器配合,將綜合自動化系統中的測量、保護功能與饋自動化系統中的重合功能相結合,不僅可以運用於變電站的改造,實現站內設備、路的保護;還可以運用於城鄉環網中,通過多次重合,消除暫時,隔離永久
  16. And to the electric capacity type voltage mutual inductor, because it compares with electromagnetic type voltage mutual inductor, transient state its bad to respond characteristic, as circuit when making the short circuit two times trouble, the voltage two times delays dropping to zero while needing to pass certain one

    而對于電容式電壓互感器,由於它與電磁式電壓互感器相比,其瞬態響應特比較差,當而使二次短路時,二次電壓需經過一定的時延後才能下降到零。
  17. This paper analyses the transient character of line fault when the neutral point connects to ground in different ways. from the angle of signal processing, the wavelet packet analysis theory is introduced to selecting fault, in which the fault character is not the steady signal but the transient signal

    本文在中點不同接地方式下,研究和分析了特徵量的暫態特點,主要從信號處理的角度,提出將小波包分析理論運用到
  18. Though microprocessor - based adaptive single - phase reclosing scenario can distinguish instantaneous fault from permanent fault definitely and avoid the blindness of traditional automatic reclosing, in some cases, adaptive reclosing can confound instantaneous fault with permanent fault. so it has defects too

    微機式自適應單相重合閘在重合閘之前,雖然可以明確地區分出路發生的是瞬時還是永久,從而避免了傳統自動重合閘的盲目
  19. This paper has proposed one new way of thought of differentiating the fault type. after observing the physical course of the single - phase grounding of transmission line, analyzing by the wavelet transformation the transient signals sampled during the fault period from the moment that single - phased grounding occurs to the moment that line breakers work, we can distinguish temporary fault from permanent one through the wave form

    本文提出了一種不同於現有類型判別的思路,通過考察路單相接地的物理過程,利用小波變換理論分析處理路單相瞬時和永久發生后斷路器開斷前時間段的暫態信號,通過波形識別區分兩種
  20. One is null oscillation occurred in the ehs valve, the second is the failure in the torque motor circuit, and the third is the load disturbance in the actuator

    然後對系統中其他幾種作了分析,包括伺服閥中位顫振;液壓缸運動慣變化
分享友人