線路壓差 的英文怎麼說
中文拼音 [xiànlùyāchā]
線路壓差
英文
line regulation- 線 : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
- 路 : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
- 壓 : 壓構詞成分。
- 差 : 差Ⅰ名詞1 (不相同; 不相合) difference; dissimilarity 2 (差錯) mistake 3 [數學] (差數) differ...
- 線路 : 1. [電學] circuit; line 2. [交通運輸] line; route
-
We can use the mm5 model in definite time, definite area weather forecasting. we conclude that : : the moving route of this necw in its developing progress was direct - south along latitude, the cold air is rough, and just this made the rough vertical velocity ; the necw southern moving and conflicting with the west pacification sub - tropical high makes rough jet steam. the plenty south - west warm and wet air made by the jet stream gave the rainstorm demanded vapor ;. the rough vertical velocity by jet stream is a main reason in this rainstorm ; the mm5 model uses four - direction analysis data as its input, this avoids some errors occurred in observe and transfer, thus made the result more useful
綜合分析認為: ( 1 ) 、這次冷渦在其發生發展過程中,其移動路徑是沿經圈直線南壓,攜帶的冷空氣勢力較強,形成槽后較強的垂直運動; ( 2 ) 、西太平洋副熱帶高壓偏北位置與東北冷渦南壓形成的急流軸,把源源不斷的西南暖濕氣流輸送到遼西地區,也就是急流軸的左前方位置,為這次暴雨的產生提供了充足的水汽來源; ( 3 ) 、低空急流不但為暴雨輸送水汽,其造成的較強的垂直環流也是產生強降水的一個主要原因; ( 4 ) 、 mm5模式以四維同化資料作為初始場,最大限度地避免了觀測誤差可能造成的積分不穩定,提高了模擬結果的參考價值。The traditional protections, including the phase differential protection based on high frequency, the directional protection based on high frequency and the distance protection cannot meet the demand of these developments
在我國高壓線路保護中有著豐富運行經驗的高頻相差保護、高頻方向保護和距離保護等,很難滿足這些新情況對保護的要求。Aiming at the study actuality of fan performance monitoring system and analysis of fan performance curve changes affected by inlet - box and the different fixed - angles of guide blades in the course of installation, a fan flow monitoring model based on rbfnn in whole flow zone was established in this thesis. in the model, the method of no throttle and fan performance curve were used as basis. and on the basis of that model, fan performance curves of 4 - 73no. 8d were approached with experimental data of different speed, different opening - angles of guide blade and different resistance of pipeline, the precision and the error law of model were studied
本文針對電站風機性能監測系統研究較少的現狀,在實驗的基礎上分析了現場加裝進氣箱和由於安裝造成的導流器葉片開度不一致對風機性能曲線的影響,並在此基礎上採用無節流方法測量流量,以風機調節性能曲線為依據,建立了基於徑向基函數( rbf )神經網路的風機流量全程監測模型;以實驗室4 - 73no . 8d離心風機為研究對象,探討了rbf神經網路差壓模型在變轉速、變導流器開度和變管網阻力等工況下的應用精度和誤差分佈規律;最後用visualc + +語言開發了風機性能在線監測系統。Through analysising the characteristics of the power system with floating neutral point deeply, the paper puts forward a new plan of single - phase to ground fault line selection on the base of s ' s signal injecton method and gives the hardware and software design. in this design, the high speed sampling and data processing is carried out through using dsp processor ; the large electrice current is drived through the application of a high - performance audio power amplifier and transformer ; the communication between host computer and detectors is realized through rs485 bus technology ; the difference multilevel frequency - selected amplifier is designed and the feeble signal of space is sampled on the base of the theory of magnetic induction ; the interface between dsp and exterior chip and rs485 interface logical is designed through using fpga ; the using of lcd module and keyboard interfacing chip makes the interface between human and machine ; the programme of host computer and detectors is designed through using blocking design method
在本設計中,採用高速的dsp處理器,實現了對故障特徵信息的高速採集與處理;採用大功率的功放晶元與變壓器配合的方法,實現了大電流信號的驅動輸出;採用485總線技術,組建了裝置主機與多探測器之間的主從式通訊網路,實現了多干擾條件下裝置主機與多探測器的可靠通訊;設計了差分式多級選頻放大電路,採用磁感應的方法實現了對空間微弱信號的接收;利用fpga技術,實現了控制器與多外設的介面及數字信號的串並轉換;採用了先進的lcd液晶顯示模塊及鍵盤介面晶元,設計了人機信息交互的介面;採用了模塊化的軟體設計方法,開發了裝置主機及探測器的軟體程序。In order to make the sensitivity of 2 - demension accelerometer along the two main arbors almost identical, symmetric four - beam structure that embeds a double - sides interdigitated differential capacitive with puckered beam in two directions was used as sensitive component. in addition, the differential capacitive accelerometer fabricated by bulky silicon micromechanical technique has high sensitivity, wide measurement scope, less nonlinear error, and simple converting circuit. then, the structure parameters of the sensitive component were calculated and stimulated, which results in a set of the optimized structure design parameters, main fabrication procedure and several key fabrication technology
為使二維振動傳感器在兩主軸方向的靈敏度大致相同,敏感元件採用高度對稱的四梁結構,其中每個軸向上均採用帶折疊梁的雙側叉指電容結構,採用體硅微機械工藝製作的高深寬比叉指電容式敏感元件,具有高靈敏度、寬量程、非線性誤差小、外圍電路簡單等優點;對設計的敏感元件結構參數進行了計算,並利用有限元法進行了模擬分析,根據模擬結果得出了優化參數;在確定敏感結構的基礎上,研究了敏感元件採用體硅微機械加工工藝製作的工藝流程和關鍵工藝技術;對敏感晶元內部的c - v介面電路進行了原理設計與分析,利用差動測量技術得到由振動引起的微小電容變化量,經c - v介面電路進行相位調制處理,然後通過解調輸出與加速度成正比的電壓信號。In this paper, the application of dsp technology in electric power measurement meter has been studied, meanwhile analysed the error of the electronic energy meter, put forward the measure to compensate error with software method. it not only changes the precision degree of electric power measurement meter, but also avoids the disadvantage from error compensate with hardware method, it is unnecessary to adjust the sample value of voltage and electric current in circuitry
對dsp技術在電度表中的應用進行了研究,對電度表系統的誤差進行了分析,提出了採用軟體方法來補償誤差的措施,使電度表的精度達到了設計要求,又避免了利用硬體進行誤差補償所帶來的弊端,不用在線路中調整電壓、電流采樣值,有利於生產。In the paper, the transmission power of section constituted by the assigned branch is seen as objective function, assigning the adjustable generators both in sending system and receiving system, assigning the faults set, including the constraint conditions such as the differences between the angles of rotor and the inertia center angel of the whole system, the thermal stability of branch and node voltage, obtaining the results by using interior - point solution and line - predominant jordan
本文提出的考慮暫態穩定約束的可用輸電能力演算法是以指定線路組成的斷面的傳輸功率為目標函數,指定送端系統和受端系統中參考調節的發電機,指定故障集情況下,以發電機轉子相對全系統慣性中心的角度差、線路熱穩定、節點電壓等構成約束條件,採用內點法和行主元約當逐行消去法求解問題的最優解。Data synchronization for current differential protection based on optical fiber channel for ehv amp; uhv long transmission line
特高壓長線路光纖縱差保護數據同步Data synchronization for current differential protection based on optical fiber channel for ehv amp; amp; uhv long transmission line
特高壓長線路光纖縱差保護數據同步This article describes the plc ’ s using enviroment and the users ’ needs in details, and then tells the differences between the dplc and the troditional plc. it also describes how to decimation and compress the tele - voice, how to deal with the data tunnels, and the multiplex data through the the line which ’ s bandwidth is changeable between 10. 8bps and 28. 8kbps this project uses the programmable vopp chips, the cpld for bus controlling, the fpga and the mcu with high processing ability. all of these ensure the high ability to process the signals and the operations
本文詳細介紹了高壓電力線載波機的使用環境和用戶需求,全數字電力載波機和傳統模擬載波的的差異;按電力調度的需求設計完整的兩路語音、兩路數據的電力線載波通訊機。詳細描述電話語音的采樣,壓縮;數據通道的處理;及在10 . 8kbps 28 . 8kbps可變線路速率通道上的數據復接處理。從實現方法上看,該項目採用專用可編程vopp語音處理晶元, cpld晶元做為總線控制,大規模fpga集成電路,高處理能力的mcu 。The simulation results in this thesis indicate that, its settling - time to full swing is 15ns with 3v supply, the total static power dissipation is less than 50mw, the differential nonlinearity error is 0. 58lsb, the integral nonlinearity error is 0. 54 lsb, spurious free dynamic range is more than 60db, and the output current can be adjusted
本課題設計的數模轉換器性能指標為:工作電壓3v ,建立時間15ns ,微分非線性誤差0 . 58lsb ,積分非線性誤差0 . 54lsb , sfdr高於60db ,總功耗不到50mw ,輸出電流可調。設計成果可應用於數據處理和控制系統電路中,具有一定的先進性和實用價值。A balanced differential line receiver senses the voltage state of the transmission line across two signal input lines, a and b
譯為: 「平衡差分線路接收器感測的是通過兩個信號輸入線a和b的傳輸線上的電壓狀態」 ?In this thesis, the fault location algorithms of hv transmission line are evaluated at first, then the factors that affect the accuracy of the fault location are analyzed, and the proper solutions are presented
本文首先對現有高壓輸電線路故障定位方法進行了綜合評述,在此基礎上對造成穩態故障測距誤差的一些尚未獲得滿意消除的因素進行了深入的探討,並提出了相應的解決方法。And to the electric capacity type voltage mutual inductor, because it compares with electromagnetic type voltage mutual inductor, transient state its bad to respond characteristic, as circuit when making the short circuit two times trouble, the voltage two times delays dropping to zero while needing to pass certain one
而對于電容式電壓互感器,由於它與電磁式電壓互感器相比,其瞬態響應特性比較差,當線路故障而使二次短路時,二次電壓需經過一定的時延後才能下降到零。In fault state, a double circuit transmission line can he decoupled into common sequence component network and differential sequence component network
由於並聯電抗器的安裝,直接測取雙回線兩端母線處的電壓及線路流過的電流進行測距,必然會引起誤差。As for the dynamic performance, the linear variable differential transformer ( lvdt ) displacement sensor using signal conditioner ad598 is not so good, so the differential rectifier is designed as the measuring circuit of the sensor so as to increase its cross - over frequency. also, the static test and dynamic test is made for the sensor along with the lvdt
由於使用線性差動變壓器信號處理晶元ad598為測量電路的差動變壓器式傳感器的動態性能不夠理想,本文設計製作了差動整流電路作為差動變壓器式傳感器的測量電路以提高傳感器的截止頻率,並對差動變壓器式傳感器進行靜態和動態標定。The extending techniques such as vector transform , excitation inrush current, ta saturation and so on are analyzed, which resolves the question that the traditional optical differential protection can not satisfy the request of line - transformer unit
同時對光纖差動保護運用於線路變壓器組時涉及的矢量變換、勵磁涌流、 ta飽和等延伸技術進行了分析,解決了傳統的線路光纖差動保護不能滿足線路變壓器組保護的要求。If the pressure changes over a large area, winds start to blow in a huge circle. high - pressure air ( area ) is pulled into a low - pressure center
如果大片地域產生氣壓差,風開始以巨大的圓形路線行進。高壓的空氣被牽引到低壓區的中心。Aiming at the pressure sensor in fcs, the static nonlinear compensation vi with neural networks ( nn ) is designed using labview. secondly, the dynamic characteristic of the sensor is analyzed
首先,本文分析傳感器的靜態特性和非線性誤差,利用labview針對飛控系統中的壓力傳感器,運用神經網路方法設計靜態非線性溫度補償儀。A new distribution model that small capacity transformer and short low voltage line is presented after analyzing the power supply ability of distribution network. it is found that this method is better than that of past through comparison between them. the advice that the fifth item of standard dl / t559 - 1996 should be modified is also presented
從理論上分析了配電網的供電能力,指出了在現有配電模式下配電網的供電能力是比較差的,提出了小容量變壓器、多布點、縮短低壓供電線路的配電模式,並將這一配電模式與現有配電模式下的常用降損節能措施進行了分析比較,證實了採用這一配電模式的優越性。分享友人