線路接地故障 的英文怎麼說

中文拼音 [xiànjiēdezhàng]
線路接地故障 英文
line-to-ground fault
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • 線路 : 1. [電學] circuit; line 2. [交通運輸] line; route
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  1. Because the fault of field windings turn - to - turn shorted do not cause much effect of the operation of the machine or its fault characteristics are not very clear, most of the faults are neglected

    轉子匝間短對機組正常運行影響不大或特徵不明顯,因此許多匝間短被忽略了,但長期運行匝間短會導致轉子圈一點甚至兩點
  2. Network manager is the world ' s leading network management system with more than 500 installations worldwide in power generation, transmission, distribution, energy trading, business management and central market applications

    一旦發生或者超負荷,網管理員系統將即時確認其點,使工作人員可以隔離,利用另一條供電,並且派遣服務隊伍直趕赴點。
  3. The single - phase grounding fault frequently occurs in neutral ungrounded system, the fault line and fault location must be found to avoid a phase - to - phase short as soon as possible

    單相在小電流系統中出現的比較頻繁,此時必須盡快找到以及大致的點,以避免兩相對
  4. Ground fault protection this function trips ( opens ) a circuit breaker or sounds an alarm in the event that there is an electrical fault between one or more of the phase conductors and ground ( earth )

    保護當一個或多個相導之間出現電氣時,保護通過跳脫斷器或報警來示警。
  5. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv電網的形式、消弧的應用范圍、兩種運行方式供電可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以電纜為主的城區10kv電網中性點方式的選擇問題進行研究。論文首先對10kv電網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變電站10kv電網的實際參數來建立數值計算模型,在考慮了電網電容電流變化、中性點電阻取值大小、電阻值變化等多種影響因素的情況下,對中性點經消弧和經小電阻方式下電網的過電壓水平和點短電流大小進行了數值計算,其計算結果與電科院所作現場試驗進行了比較。
  6. Then the idea of integral control of automatic resonance and single - phase earth faulted line selection was put forward

    並在此基礎上給出了補償電網中消弧圈自動調諧與單相一體化的綜合控制思
  7. It includes four criterions of locating fault point ? “ transient zero sequence current amplitude law ”, “ stable base wave zero sequence current phase law ”, “ stable seventh harmonic zero sequence current phase law ” and “ s injection law ”. pointing out how the law locate the fault point to minimal fault section by applying these criterions gradually. the law will not only make up the blemishes existing in current methods for single - phase fault location in small current grounding system, but also locate the fault point to minimal fault isolating unit on fault line

    該方法通過將所包含的四個定位判據- 「暫態零序電流幅值法」 、 「穩態基波零序電流方向法」 、 「穩態7次諧波零序電流方向法」和「 s信號注入法」 -進行有選擇遞進使用,不僅有效彌補了目前已有小電流系統單相的缺陷,更將定位在最小區段。
  8. Applying relative arithmetic to all kinds of faults and calculating off - line, we can master time - distance relation chart for all kinds of faults. computation indicates : when transmission lines occur faults, the data window of protection algorithm consisting of prefault and postfault data at the same time has important significance. the following methods are useful to achieve the inverse time characteristic : calculating impedance by using flourier in a full cycle, calculating work voltage by using fault component, calculating the torque created by a phase comparator or a magnitude comparator

    實際的計算表明:輸電發生后,用前後的數據同時充滿保護演算法的數據窗,對于快速切除近區具有很重要的意義;同時利用前後的數據,下述方法可以比較好實現距離保護的反時限特性:直用全周傅里葉演算法進行阻抗計算;採用工頻變化量阻抗繼電器進行工作電壓的計算;採用轉矩的思想進行轉矩的計算。
  9. The protection constitution of connecting the ground can cut off the troubling electric circuit quickly and effectively before causing the personal casualty, a fire trouble and circuit to damage, and thus protecting the personal safety and reducing the occurrence of the trouble

    摘要保護設置能在引起人身傷亡、火災事以及損壞之前,迅速有效切斷,從而保護人身安全,減少事的發生。
  10. According to the rule of mine safety regulations, an intrinsically safe pilot circuit with perfect performance for underground motor intelligent protective systems is put forward, which can effectively avoid the phenomenon of self - starting that is caused by the earthing of control lines before starting motors, at the same time, can reliably cut off the switches to ensure the safety of underground production under operation condition no matter what the faults of short circuit, open circuit and earthing in the control circuits happened

    根據煤礦安全規程規定設計了性能完善的本質安全型先導電,起動前它能有效防止因控制造成自起動現象的發生,而且在運行中無論控制發生短、斷還是,它均能可靠跳閘,確保生產的安全,該先導電的性能指標達到了國內領先水平。
  11. In the next place, an improved algorithm of grounding fault location for tree - type distribution system which is based on new fault function and criterion measure, is proposed in order to complete fault branch ide ntification, fault location and fault value. a lot of the simulation of fault diagnosis and location by computer demonstrate that the algorithm is effective

    其次論文基於輻射狀饋的任一分支發生,通過分析與推導,建構了配電單相短點定位的定位函數和相應的判據,利用樹網單端信息完成分支識別、定位和過渡電阻定值。
  12. Computer simulation shows that the criterion measure effectively locates faults in direct distribution line, and it is also feasible to tree - type distribution system in theory but there are still some problems in practice

    經過數值模擬計算分析表明,該方法對直配定位是有效的,對樹形多分支定位理論上也是可行的,但實際應用中還有許多重要問題需要進一步深入研究。
  13. Based on the analysis of the transient and stable features of fault information on line in single carrier power supply with ineffective grounding neutral, this paper puts forward a new method for fault location in small current power system called " gradual identifying law "

    本文針對這一問題,在深入研究了中性點非有效單端供電系統發生單相上的各處信息的暫態特性和穩態特性的基礎上,提出了一種新的小電流系統單相定位方法- 「遞進信息法」 。
  14. This paper analyses the steady and transient character of line fault when the neutral point connects to ground in different ways. from the angle of signal processing, the wavelet analysis theory and the artificial neural networks are introduced to fault location, in which the fault character is not the steady signal but the transient signal

    本文在中性點不同方式下,研究和分析了零序特徵量的穩態和暫態特點,主要從信號處理的角度,提出將小波分析理論和人工神經網原理運用到定位,將基於穩態信號的定位原理轉移到基於特徵量暫態信號的定位原理。
  15. In recent years, with the large - scale reconstruction of city power system, the scale of power system is continuously expanding, and the power supply network is becoming larger and larger. in addition, the enormous use of cables in city power system increases the current through the grounded capacitor. these lead to more and more instantaneously grounding faults unable to eliminate naturally

    近年來,國家對城市電網的大規模改造,使得電網的規模不斷發展,配電網越來越大,加上城網中大量使用電纜,使電容電流大大增加,越來越多的瞬間單相不能自動消除,為了解決這一問題,我國普遍採用中性點經消弧的補償方式。
  16. When single phase to earth fault occurs on a neutral non - direct grounded power system, it is necessary to select the fault circuit quickly

    小電流系統發生單相時,盡快選出,對于系統的運行是具有重要意義的。
  17. Single - phase line - open without earth fault has been ignored for so many years because its damage is not so serious and the fault hasn ’ t explained clearly so far

    配電網架空發生單相斷長久以來一直沒有受到人們的重視,對其特徵也沒有進行清晰的闡述。
  18. For this reason, the paper gives two new arithmetic, current break arithmetic and net arithmetic, which solve the problem of fault detection in anti - arc system effectively

    為此,本文提出了兩種全新的演算法,電流突變量演算法和網演算法,有效的解決了中性點經消弧情況下單相的問題。
  19. This paper has proposed one new way of thought of differentiating the fault type. after observing the physical course of the single - phase grounding of transmission line, analyzing by the wavelet transformation the transient signals sampled during the fault period from the moment that single - phased grounding occurs to the moment that line breakers work, we can distinguish temporary fault from permanent one through the wave form

    本文提出了一種不同於現有類型判別的思,通過考察單相的物理過程,利用小波變換理論分析處理單相瞬時性和永久性發生后斷器開斷前時間段的暫態信號,通過波形識別區分兩種
  20. On the function study basis of main doublized protection type 11 and type 902 micro computer line protection device, taking permanent single phase fault occuring on power line within protected district as example, the paper analized in detail the acting behavior of type 11 and type 902 computer line protection device

    摘要在對構成主保護雙重化的11型和902型微機保護裝置功能研究的基礎上,以發生區內單相永久性為例,對11型和902型微機保護裝置動作行為作了詳細分析。
分享友人