線路斷開器 的英文怎麼說

中文拼音 [xiànduànkāi]
線路斷開器 英文
cb
  • : 名詞1 (用絲、棉、金屬等製成的細長的東西) thread; string; wire 2 [數學] (一個點任意移動所構成的...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • : Ⅰ動詞1 (分成段) break; snap 2 (斷絕;隔斷) break off; cut off; stop 3 (戒除) give up; abstai...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 線路 : 1. [電學] circuit; line 2. [交通運輸] line; route
  • 斷開 : break; discon; disconnect; disconnection; interrupt; off; open; opening; switch off; throw off; t...
  1. For the circuit - breakers of rated voltage 252kv up, the synthetic test methods are introduced according now condition because of the limitation of the transformer short - circuit capacity. the correlative prescribes on switching line - charging current in gb / t1984 - 200x " alternating - current high - voltage circuit - breaker " are discussed according to the test results and theoretic analysis

    由於合空載架空試驗對電源側的阻抗有明確的規定,這就要求試驗電源必須具有足夠大的短容量,實驗室很難滿足要求,因此,一般對較高電壓等級的採用合成試驗方法,本文介紹了利用現有條件,對252kv以上電壓等級的採用合成試驗時的試驗
  2. The paper gives the evidences for making use of auto - reclose technology in ineffectively grounded systems from its importance, feasibility and validity. to develop the single - chip microcomputer of the device, the paper does a lot of work of design hardware and software include using soft timer with task - plan solving the whole arrangement of the process

    在選裝置的實現方式上,本文提出了基於單片機方式的硬體電發方案和軟體系統設計方案,嘗試了使用80c196kb的三個軟體定時結合任務型設計方法解決程序流程的問題。
  3. Application of high - voltage explosion fuses is very abroad. in addition to protecting the electrical equipment by melting itself, disjunction or close of its tube can also be manipulated by a high - voltage insulative stick under some circumstance, for example, to switch on or off no - load overhead transmission line, no - load transformer and little burden current

    跌落式高壓熔的應用極為廣泛,不僅能保護電氣裝置,在一定條件下還能直接用高壓絕緣鉤棒來操作熔管的分合,以和接通空載的架空、小容量空載變壓和小負荷電流。
  4. Initial recovery voltage and peak recovery voltage across the circuit - breaker have an essential affect on re - strike. for assessing performance of circuit - breaker, the higher inductance and lower inductance must be considered at the same time when testing according to theoretic analysis, the directly test circuit on switching the no - load overhead by high - voltage circuit breakers of rated voltage 252kv and below, in compliance with the correlative standard jb5871 and the test devices, and the test circuit parameters have been calculated and the many testes have been carried out

    在理論分析的基礎上,考慮實驗室現有設備的情況依據標準jb5871的規定,選用合適的試驗設備,對試驗的參數進行計算,在實驗室建立了252kv及以下電壓等級充電電流直接試驗,利用該進行了數臺產品的試驗,分析了試驗結果,並根據試驗結果和理論基礎討論了gb t1984 - 200 《交流高壓》 (報批稿)關于充電電流試驗的有關規定。
  5. When switching the no - load overhead lines by alternating - current high - voltage circuit breaker which is a kind of daily operations in electric power system, over - voltage is probably bringed out and insulating property of the electric devices is breakdowned sometimes, especially, when occuring re - strike. the main purposes that the tests on switching line - charging current are performed in the laboratory are assessing re - strike performance of circuit - breakers. according to the test results, the design of the circuit - breaker is optimized and re - strike performance is improved

    交流高壓是電力系統中最關鍵最重要的設備之一,合空載架空是電力系統中常見的操作,操作過程中通常會出現過電壓,對系統絕緣造成威脅,嚴重時會破壞系統的絕緣性能,發生事故,隨著電力系統電壓等級的提高、輸電延長及傳輸容量的增大,由操作過電壓引起的絕緣閃絡、設備破壞事故的幾率更加突出。
  6. Based on the analysis of the paper, we can draw the conclusion that this device has several issues to be solved to put into use, such as low filtering capacity, large bulk and area the device occupies, complexity of connection, and the hazard of ferro - resonance existing when switching without disconnecting the circuit of the step - up transformer

    經過分析發現,這種補償方案存在一些問題,如濾波能力低,補償裝置體積大,佔地面積多,接復雜;並且如果在投切過程中不將升壓變壓高壓側迴,存在著發生鐵磁諧振的危險。
  7. Air circuit breaker an air circuit breaker automatically interrupts the current flowing through it when the current exceeds the trip rating of the breaker

    空氣空氣的功能是當電流大小超過的過流跳脫設定值后自動
  8. High - voltage alternating current circuit - breakers - guide for short - circuit and switching test procedures for metal - enclosed and dead tank circuit - breakers

    高壓選擇電流.金屬封閉的和不通電的箱式關試驗設備指南
  9. High - voltage alternating current circuit - breakers - inductive load switching

    高壓選擇電流.感應負載
  10. Standard for metal - enclosed low - voltage power circuit breaker switchgear - amendment 1 : short - time and short - circuit withstand current tests ; minimum areas for multiple cable connections

    金屬殼密封的低壓電力關設備標準.修改1 :短時間和短可耐電流測試;多電纜連接的最小區域
  11. Its rated voltage class includes 40. 5kv, 72. 5kv and 126kv. this product is applied for connecting and disconnecting of hv lines at no load, electrical isolation between inspected hv busbar, circuit breaker and other electrical equipment, and live hv lines, as well as connecting and disconnecting of small capacitance current and inductance current. the new - type hv disconnecting switch can effectively prevent such common problems as overheat in galvanic circle, misoperation and

    該系列產品為三相交流50hz的戶外高壓電設備,額定電壓等級有33kv 40 . 5kv 72 . 5kv和126kv ,供高壓在無負載情況下進行合,以及對被檢修高壓母等電氣設備與帶電的高壓進行電氣隔離之用,也可用於合小的電容或電感電流,並可按用戶要求加裝接地關。
  12. Its rated voltage class includes 40. 5kv, 72. 5kv and 126kv. this product is applied for connecting and disconnecting of hv lines at no load, electrical isolation between inspected hv busbar, circuit breaker and other electrical equipment, and live hv lines, as well as connecting and disconnecting of small capacitance current and inductance current. the new - type hv disconnecting switch can effectively prevent such common problems as overheat in galvanic circle, misoperation and part rusting

    該系列產品為三相交流50hz的戶外高壓電設備,額定電壓等級有33kv 40 . 5kv 72 . 5kv和126kv ,供高壓在無負載情況下進行合,以及對被檢修高壓母等電氣設備與帶電的高壓進行電氣隔離之用,也可用於合小的電容或電感電流,並可按用戶要求加裝接地關。
  13. In this dissertation, firstly, characteristics of no - load overhead line and processes of switching no - load overhead line by circuit - breakers are analyzed, then, transient recovery voltage across circuit - breaker are calculated emphatically and the factors of affecting transient recovery voltage are analyzed

    這就要求具有良好的合空載架空的能力。實驗室進行充電電流試驗是考核合空載架空性能的重要手段,通過試驗可以優化的設計、提高合空載架空性能。
  14. Paralleling breaker a paralleling breaker is the circuit breaker that connects the generator set to the emergency bus, and across which all the individual generator synchronizing functions occur

    並聯關並聯關是連接發電機組和應急母排的,所有的單個發電機通過它完成同步運行。
  15. See air circuit breaker, main breaker, molded case circuit breaker and power circuit breaker

    (見空氣、主關、塑殼等) 。
  16. Main breaker a main breaker is a circuit breaker at the input or output of the bus, through which all of the bus power must flow

    關主關是在母排輸入或輸出端的,所有的電流都要從那通過。
  17. After the user certification is passed, the broadband access server ( bas ) sends start - of - billing packet to the back - end radius server. after the user logs off ( e. g., active user hang - up, unusual outage and network breakdown ), bas will send end - of - billing packet to the back - end radius server

    在用戶認證通過后,由寬帶接入服務( bas ) ,向後臺的radius服務發送計費始包,在用戶下后(用戶主動掛、異常死機、網等) ,由bas向後臺的radius服務發送計費結束包。
  18. Thus, it can be easily deployed without the use of any existing network infrastructure and make mobile users more convenient to access it. motion is wmsn ' s main characteristic which cause dynamic variety of network topology. the wireless datalink status information sense scheme design introduced in this paper is developed for this specific environment. it mainly informes dynamic routing module to update dynamic routing information in time and improve its response time to dynamic variety of network topology

    網際網與傳統的有網際網相比,其最顯著的特徵就是其移動性,因此無( wr )需要及時感知網拓撲結構的變化,並根據發生的變化對動態由進行調整,這要求能通過無驅動進行相鄰wr加入與離的感知,主動及時地向由模塊通告無等相關信息。
  19. This paper has proposed one new way of thought of differentiating the fault type. after observing the physical course of the single - phase grounding of transmission line, analyzing by the wavelet transformation the transient signals sampled during the fault period from the moment that single - phased grounding occurs to the moment that line breakers work, we can distinguish temporary fault from permanent one through the wave form

    本文提出了一種不同於現有故障類型判別的思,通過考察單相接地故障的物理過程,利用小波變換理論分析處理單相瞬時性故障和永久性故障在故障發生后前時間段的暫態信號,通過波形識別區分兩種故障。
  20. Switchgear - low - voltage ac power circuit breakers used in enclosures - test procedures

    關設備.封裝式低壓交流電力.試驗程序