脈動儀 的英文怎麼說
中文拼音 [màidòngyí]
脈動儀
英文
oscillograph-
Leave sensor probe in place until oximeter reaches constant value and pulse display reaches full strength during each cardiac cycle. read spo2 on digital display
打開電源,接通血氧儀。觀察脈搏波形/強度和嘟嘟聲。對比血氧儀脈率與病人橈動脈搏動。Other common devicesintravenous medication pumps allow the nursing staff to titrate medications ; foley catheters and urine collection bags aid in monitoring urine output ; sequential compression devices squeeze the lower extremities and reduce the incidence of deep venous thrombosis ; transvenous pacemakers stimulate the patient ' s heart to beat ; dialysis machines remove fluid and correct electrolyte and acid - base disturbances ; intraaortic balloon pumps assist the heart ' s contractility ; and neurologic monitoring systems measure intracranial pressure
其他常用裝置靜脈內給藥泵由普通護士用於滴定藥物;弗利氏導管和集尿袋幫助監測排尿量;連續壓迫裝置擠壓下肢,減少深部靜脈血栓形成;經靜脈起搏器刺激病人心臟跳動;透析儀除去液體,糾正電解質和酸堿紊亂;主動脈內氣囊泵支持心臟收縮;神經病學監測系統測定顱內壓。Coronary perfusion pressure monitor
冠狀動脈灌注壓力監護儀All subjects underwent spirometry, measurement of aortic pulse wave velocity ( pwv ) and augmentation index, dual - energy x - ray absorptiometry, and blood sampling for inflammatory mediators
所有的研究對象接受肺量測定法,測量主動脈脈沖速度和增強指數,雙能x線吸收儀和採集血樣分析炎性介質。All subjects underwent spirometry, measurement of aortic pulse wae elocity ( pw ) and augmentation index, dual - energy x - ray absorptiometry, and blood sampling for inflammatory mediators
所有受試對象都進行肺活量測定、主動脈脈搏波速( pw )和增強指數測量、雙能x -線吸收儀檢查,以及炎癥介質血樣檢測。A novel pneumatic massage device for lower limb varix
治療下肢靜脈曲張的新型氣動式按摩儀A new type of pneumatic massage device treating lower limb varicosity and its clinical application
治療下肢靜脈曲張氣動式按摩儀的研製及其臨床應用The sediment - laden flow fluctuating velocimeter designed in this study has a well static and dynamic charateristic
本文研製的渾水脈動流速儀具有良好的靜、動態特性。Simulated experiments effects of intrathoracic pressure change on hemodynamics three models that simulated the anatomic arrangement of the venous return systems and chest cavity were established to investigate the hydromechanic principle of the different influence of the itpc on the ventricular fillings. effects of intrathoracic pressure change on the motion of interventricular septum ( ivs ) acuson ' s sequoia 512 ultrasonographic system was used in this study to record the m - mode and two - dimensional cineloop images of the simulated interventricular septum movement with different intrathoracic pressure changes
指標觀測觀察並記錄外周靜脈壓和模擬胸腔壓力分別變化及同時變化時,模擬右心室的容積變化;觀察並記錄模擬胸腔壓力變化時,模擬肺血管床和左心室內壓力的變化;用sequoia512超聲心動圖儀觀察胸腔壓力變化對模擬心臟室間隔運動的影響。Intravenous medication pumps allow the nursing staff to titrate medications ; foley catheters and urine collection bags aid in monitoring urine output ; sequential compression devices squeeze the lower extremities and reduce the incidence of deep venous thrombosis ; transvenous pacemakers stimulate the patient ' s heart to beat ; dialysis machines remove fluid and correct electrolyte and acid - base disturbances ; intraaortic balloon pumps assist the heart ' s contractility ; and neurologic monitoring systems measure intracranial pressure
靜脈內給藥泵由普通護士用於滴定藥物;弗利氏導管和集尿袋幫助監測排尿量;連續壓迫裝置擠壓下肢,減少深部靜脈血栓形成;經靜脈起搏器刺激病人心臟跳動;透析儀除去液體,糾正電解質和酸堿紊亂;主動脈內氣囊泵支持心臟收縮;神經病學監測系統測定顱內壓。Other : connected with the isolanting diaphragm part ( code : bw ), ytfn series can be used to measure the pressure of an impulsing, a shocking or a suddenly unloaded medium
Ytfn系列儀表配裝強耐震體后,可測量劇烈脈動、沖擊及突然卸荷的介質壓力。On the basis of theory analysis, the average transmitted light intensity ( correspond to dc value ) was determined as characteristic parameter of raw water using photoelectric method for monitoring the fluctuation of transmitted light and photometric dispersion analyzer ( pda ). the dc value was closely related to both particle concentration and surface area of sand clay simultaneously. the experimental results shows that there is an exponential function relation between dc and surface area of sand clay in unit volume water ( sp ) : dc = asbp in which a and b are empirical coefficients. then the formula of macromolecule flocculant dosage is found to be d = f ( dc ) = e ( dc ) f in which e and / are empirical coefficients and the average correlation coefficient equal to 0. 981. so the model of automatical control system of water treatment plant was established using the formula
應用透光率脈動檢測技術和光散射顆粒粒度分析儀( pda ) ,通過理論分析,將pda的輸出信號之一? ?平均透光強度(對應于dc值)作為原水的特性表徵參數, dc值可以同時反映顆粒濃度和比表面積因素的影響,試驗結果證明, dc值與單位體積水中泥沙顆粒總表面積s _ p之間具有很好的冪函數關系: dc = cs _ p ~ d ,式中c 、 d為經驗系數,進而得到了以dc值為參數的高分子絮凝劑投藥量公式: d = f ( dc ) = e ( dc ) ~ f ,式中: e 、 f為經驗系數,平均相關系數達0 . 981 ,利用所建立的公式,建立了前饋? ?后饋聯合控制的在線自動投藥模型。Provides for the exchange of information among its members, hosts continuing education seminars, publishes a newsletter, and represents the industry for important issues facing medical publishers today
-致力於中醫基礎理論尤其是中醫脈診理論的研究,研究基於北京中醫藥大學重點學科博士們提供的中醫脈診儀和自動診斷軟體。The turbulent flow in open channel is tested with laser - doppler anemometer, in which the longitudinal time average velocity and fluctuating velocity of turbulent flow in open channel under the conditions of the sudden changes of roughnesses at different water depths are measured
摘要通過激光測速儀,對壁面糙率突變時的明渠紊流進行試驗,測量了糙率突變不同水深情況下明渠紊流的縱向時均流速和脈動流速。Vibration - resisting electricity contact pressure meter is used for occasion by environment quake vibration excle in pulsaling lash by medium - resistant and suddenly unload ; usually it is make use of form a complete set by relevant eletric device ( such as relay and contact appliance and so on ). so realized attain auto - control post a letter ( give an alarm ) for pressure system by survey. compare with ordinary for a special model electricity contact pressure meter, zhe indicator ' s function by survey pressure more stabilize, more accurate, and powerful of resist eletric arc, and it is use for even more long life
耐振電接點壓力表,適用於環境劇烈振動場合,可耐介質的高強脈動沖擊及突然卸荷;通常該儀表經與相應的電氣器件(如繼電器及接觸器等)配套使用,即可對被測(控)壓力系統實現自動控制發信(報警)的目的,與普通專用型電接點壓力表相比,指針測壓性能更穩、準,且抗電弧強大,使用壽命更長。Measurement of fluid flow in closed conduits - guidelines on the effects of flow pulsations on flow - measurement instruments
密封管道中液體流量的測量.脈動流動對流量測量儀器影響的指南This system provides pulse signal and direction signal to step motor driver by computer ’ s controlling step motor control card, and makes motor and guage ’ s pointer rotate. computer gets the micro displacement measured by grating measuring system via rs232 serial port, and acquires guage ’ s image by high precison ccd camera, then processes the guage ’ s image by software, including pre - processing, graying, binarization, thinning and hough transform, so as to recognize the position of guage ’ s pointer, finally calculates all kinds of precision on basis of algorithm established by national detecting rules of gauges
本系統通過計算機控制步進電機控制卡來給出步進電機驅動器需要的脈沖信號和方向信號,進而帶動電機驅動儀表指針轉動,計算機通過串口實時採集光柵測量系統的微位移信號,並且通過高精度ccd攝像機實時獲取表盤圖像數據,同時通過計算機軟體實現表盤圖像處理,包括預處理、灰度化、二值化、細化和hough變換等,最終快速識別出表盤指針的位置,並根據國家表類檢定規程所制定的演算法檢定出指針式儀表的各種精度。Uses : extensively apply to dc and pulse circuits of broadcasting and tv sets, all kinds of instruments, and communication equipments
用途:廣泛用於廣播電視產品,各種儀器和通訊設備的直流及脈動電路中。Suitable for dc or pulsed circuit in various economical lamps and electronic instruments requiring a high frequency characteristic, high power and high voltage withstand
適用於頻率特性高、功率大、耐高壓的節能燈電路和各類電子儀器的直流或脈動電器中。Generally, under the situation of steady tested pressure, the maximum working pressure shall not exceed 2 / 3 of the upper limit value of the instrument ; while in measuring pulse pressures, the maximum working pressure shall not exceed 1 / 2 of the upper limit value of the instrument ; and while in measuring high pressures, the maximum working pressure shall not exceed 1 / 3 of the upper limit value of the instrument
一般在被測壓力穩定的情況下,最大工作壓力不應超過儀表上限值的2 / 3 ;測量脈動壓力時,最大工作壓力不應超過儀表上限的1 / 2 ;測量高壓時,最大工作壓力不應超過儀表上限的1 / 3 。分享友人