表乙靈 的英文怎麼說

中文拼音 [biǎolíng]
表乙靈 英文
epiethylin
  • : Ⅰ名詞1 (外面;外表) outside; surface; external 2 (中表親戚) the relationship between the child...
  • : Ⅰ形容詞1 (靈活; 靈巧) quick; clever; bright 2 (靈驗) effective Ⅱ名詞1 (精神; 靈魂) spirit; ...
  1. The results showed that the extract by etoac presented a significant effect on staphylococcus aureau 、 bacillus cereus 、 bacillus megateriurn 、 proteus species, corynebacterium pekinense 、 trichoderma viride and aspergillus flavus all of which belonged to bacteria ; the extract by n - buoh presented significant inhibitory effect on bacillus mesentericus, bacillus subtilis 、 proteus species 、 bacterium prodigious, trichoderma viride and aspergillus flavus all of which belonged to bacterium ; the inhibitory effect become stronger and stronger with the extract concentration increaseing and the water phase of the extract did not present any antimicrobial effects

    結果明,酯萃取物對細菌中的金黃色葡萄球菌、蠟狀芽孢桿菌、變形桿菌、巨大芽孢桿菌、北京棒狀桿菌和黴菌中的綠色木霉、黃麴黴有明顯的抑菌作用;正丁醇萃取物對細菌中的馬鈴薯芽孢桿菌、變形桿菌、枯草芽孢桿菌、桿菌和黴菌中的綠色木霉以及黃麴黴有明顯的抑菌作用,且提取物的抑菌作用隨濃度增大而增強,而水相則沒有抑菌活性。
  2. Results of calculation indicate that the bubble & dew points may be reduced extremely, but the relative volatility rises slightly and the separation of them is affected hardly by decreasing pressure. and this article puts forward more reasonable modifying suggestions after analyzing numerically in detail the common method of determining the position of sensitive plate in distillation tower and finds out something unsatisfactory about it

    計算結果明,減壓可大大降低苯?苯烯物系的泡、露點,但相對揮發度增加甚微,對其分離的難易程度幾乎無影響;對常用求取精餾塔敏板位置的方法進行了詳盡的數值分析,對其不合理性提出了改進措施。
  3. Results show that triple reflection signal and quintuple reflection signal of ytype and s type are less 12db, 16. 67 db and 11. 8 db, 17. 3 db than that of " - ' " type saw mass sensor device. experiment results show that insertion loss ( about 14db ) of the devices in center frequency is close to the theoretical value ( about 16db ) developed by p matrix representation. sensing characteristics of y type and s type saw mass sensors have been also tested and analysed in detail. ethanol and pure water mixed solution containning trace nacl is titrated into mass loading area of y type and s type saw mass sensors devices to detect their mass loading sensitivities

    本文對y型和s型雙聲路saw質量傳感器件的傳感特性進行詳細測試分析,在y廠書型和s型雙聲路聲面波器件的質量沉積區中滴定含有微量naci溶質的醉和水的混合溶液,以測試器件的質量沉積效應敏度,它們分別約為2967ppm . cm丫夢g ( y型)和3一15ppm . emz /協g ( s型) ,與理論值38 . 93ppm . emz / 「 g相近,拼處于國內外同型和s型雙聲路聲面波器件的頻率一溫度特性幾,其單聲雙聲路相對溫度系數約為10一12hz / ,處于國內外同類研究先進水平。
  4. An injecting biosensor was also investigated. the preliminary result showed that it had the advantage of simplifying the replacement of enzyme membrane. however, the sensitivity of this biosensor still needed some improvement

    同時,本文嘗試了酰膽堿酯酶的其它一些固定化方法,並對反應器式生物傳感器進行了初步研究,結果明,雖然其具有更換酶膜方便的優點,但是檢測敏度仍有待提高。
  5. Applying r. f. glow discharging plasma to process the surface of the trlethanolamine coating on the qcm sensor, the qcm sensor ? performances are well ameliorated. analysis and testing indicates that the processed sensor responses to various organic compounds vapor steadily, sensitively and quickly

    實驗明:處理后的三醇胺塗膜qcm傳感器依然現出對醛的良好的化學選擇性與敏度,同時最為重要的是,器件的性能大有改良:響應穩定可靠,易於再生,且使用壽命較長。
分享友人