  1. The methods of deciding water and hot watersupply design second flow imside of buildings include square root method, experience method and probability method

    建築內部給水、熱水設計秒流量算方法有平方根法、經驗法和概率法等。
  2. The design second flow formula in our country is used in the sovia union before. but the sovia used the probability method in the 1960s

    如我國設計秒流量公式是沿用前蘇聯的算方法,但蘇聯早在七十年代就以廢除,並使用概率法。
  3. Main contents for studying of the paper is : ( 1 ) analysing the outcome, characteristic and the problem of the hot water supplydesign second flow method in the europe and the usa. ( 2 ) it is determined that value frequenly of different fixture use in the period of using water high peak. ( 3 ) the relation between the n and the hot watersupply design second flow is got by applying program to computer under the different probablity

    本課題研究的主要內容為: ( 1 )分析對比歐美主要國家熱水設計秒流量算方法的結果、特點及存在的問題; ( 2 )根據我國居民生活用熱水特點,由用水標準推算出各類型水用戶用水高峰期的衛生器具使用概率; ( 3 )編制算機程序,算不同使用概率情況下,給水當與熱水設計秒流量的關系表; ( 4 )建立熱水設計秒流量q _ g和給水當n與使用概率p之間的相關關系; ( 5 )繪制《建築給水排水規范》中有關熱水設計秒流量算方法的算用圖表。
  4. Only the flux being decided properly, the design will match the fact well, which met the demand of user and saved the material. this paper analyzed the formulas of calculation of design flow per second and maximum flow per hour used in water supply

    而是介於最大日瞬時用水和最大時平均之間,只有合理的確定給水的大小,才能使得與實際情況能比較好的符合,既滿足了小區用戶的實際需求,又節省了管材、備等的造價。
  5. Many experts and designers hold that the design flow provided by the normal formal is a lot of lack, everybody consistently thinks that the probability method is reasonable and viable in calculating the water supply by many expert, scholar, professor ' s research

    許多國內專家及人員反應我國現行規范公式給出的設計秒流量應用於實際中存在很多不足,通過許多專家、學者、教授的研究,大家一致認為用概率論方法算給水是比較合理及可行的。
  6. According to the type of buildings, with many data, we draw such conclusion that the equivalent of fixtures n and frequency of use p are interrelated to the design flow qg

    按照住宅類型,進行了大的數據分析得出:當總數n與使用概率p的乘積和設計秒流量q _ g存在很大的相關性的結論。
  7. The determination of water supply design second flow is one of the most important subject in building water supply and drainage and is the moist frequent question in designing

    給水設計秒流量算是建築給水排水中最重要的課題之一,是中使用最頻繁的工作,如何將設計秒流量算更符合實際情況是一個值得探討的問題。
  8. The paper makes quantification about the two important factors influencing the design flow - - frequency of fixture use p and water supply reliability p. the paper presents that water supply reliability does not make marked influence. so it is important to get a proper value frequency of fixture use

    本文分別對影響給水設計秒流量的兩個最重要因素? ?衛生器具使用概率p和給水保證率p _ r ,進行了化分析,提出給水保證率對的影響程度不顯著。
  9. According to the scales of small residential communities, the number of people, water supply of small residential communities have its characteristics with regulations, namely the flux formula differs from flow per second and maximum flow per hour used in water supply, but between them

    住宅小區供水因受其供水范圍和人口數的影響,其用水規律有其特點,即其應不同於按最大日瞬時用水所確定的建築內部的設計秒流量,又不同於按城市給水最大時算所得到的平均
  10. On calculation the disquisition discusses whether design flow of present design - standard is fit for high - building ; throws emphasis on attention to " control number " on calculation of fire - fighting systems ; expatiates on how to make a calculation of system flow and pipe of sprinkler systems. . .

    在水力算方面,討論了現行規范中設計秒流量公式對于高層建築干管的適用與否;強調了「控制數」在消防系統等算中應謹慎對待;闡述了如何準確進行自動噴水滅火系統的系統及配管的算。
  11. The hot water and the watersupply second flow formula is the same in the existing criterion. but the veicle, the law, the time and the probability that the people using hot water is deflsrent from that of the water. so it should have a method

    現行規范中熱水設計秒流量算方法與給水算方法一樣,但熱水的用水器具、用水規律、使用時間和用水概率都與給水不同,應有不同的算方法。