負變壓線 的英文怎麼說
中文拼音 [fùbiànyāxiàn]
負變壓線
英文
kaballobar-
Because of the elements which run under nonideal linearity and unentire symmetry in the power system, the loads which are different and change randomly, the methods which adjust and control the system faultily and operate improperly, the disturbance and the malfunction which happen somewhere, the current and voltage in the supply system are distorted seriously and thus large amount of harmonics are produced
但是,由於電力系統元件運行的非理想線性或非完全對稱、負載的性質各異且隨機變化、調控手段的不完善以及錯誤操作、外來干擾和各種故障的存在,供電網中的電流(電壓)發生畸變,產生大量諧波。Delay trip multiple curves can choose the " inertia delay ", or to prevent electrical transformer loading terminal unnecessary trip
多種延時跳閘曲線可選購的"慣性延時" ,可防止電動機或變壓器負載端出現不必要的跳閘This paper deduced the harmonic parameter models of electrical transformers, generators, transmission lines and electrical loads in detail
本文較為詳細的推導了電力變壓器、發電機、輸電線路、電力系統負荷等的諧波參數模型。The thesis discussed the fundamental which is voltage grade, reliability, connection mode, transformer load and power equipment
論文闡述了城市電網規劃中電壓等級、供電可靠性、接線方式、變壓器負荷率取值和供電設施的基本原則。Three phase dry type power transformer, which make it with those features : safety, reliability, and energy saving, fireproof, flameproof, simple maintenance etc., the design is advanced ; the structure of products is reasonable and the outline is fine, the main performances of the products are much better than the national standards, for example, partial discharge level no - load loss, on - load loss, noise level, it is adaptable for application on heavy humidity and severely pollute places which are near to lake, sea and rive, as well as, high demand - fireproof, heavy load capacity place, such as : high building, airport, station, port, underground, hospital, electrical power station, metallurgy, shopping center, residential area and petroleum chemical industry, nuclear power station, nuclear - powered submarine
非包封線圈三相干式變壓器,具有安全可靠節能防火防爆維護簡單等優點。其設計先進結構合理外形美觀。主要性能指標均優于國內標準,如局放水平空載損耗負載損耗噪聲以及能適應高溫度環境使用等,可安裝在靠近湖海河邊污穢潮濕的環境及防火要求高負荷較大的地區,適用於高層建築機場車站碼頭地鐵醫院電廠冶金行業購物中心居民密集區以及石油化工核電站核潛艇等場所。In at power supply system some transformers with special connection mode, such as scott transformer, anti - scott transformer, balance transformer and so on, are usual used. the voltage ratio is one of important parameters of transformer
採用斯科特變壓器、平衡變壓器等特殊接線方式變壓器作為主變壓器,能有效抑制負序電流,減少有功損耗和電壓損失,提高牽引機車的過負載能力。Owner responsible for connecting main incoming cables to high voltage side of transformer
業主負責把主進線電纜送至變壓器高壓測Furthermore, it is very important that improve the autoimmunization of substation without watch - keeper. in the design of substation, we predigest main wiring with a minitype base and adopt simple wire - connection : dule t type is used in 66kv side, segmented single bus - bar with hospital bus - bar is used in l0kv for major load
在該無人值班變電所的設計中,以小型化模式為基礎,簡化主接線: 66kv側採用雙t接線方式,正常時雙線雙變壓器分列運行; 10kv側由於饋電線路較多,負荷較為重要,因此採用單母線分段帶旁路接線方式。Application of high - voltage explosion fuses is very abroad. in addition to protecting the electrical equipment by melting itself, disjunction or close of its tube can also be manipulated by a high - voltage insulative stick under some circumstance, for example, to switch on or off no - load overhead transmission line, no - load transformer and little burden current
跌落式高壓熔斷器的應用極為廣泛,不僅能保護電氣裝置,在一定條件下還能直接用高壓絕緣鉤棒來操作熔管的分合,以斷開和接通空載的架空線路、小容量空載變壓器和小負荷電流。A simplified analysis method of distribution networks is presented. the voltages and the power on / through both end of the feeder are used to describe the load and its distribution within the feeder line. only field test datas from feeder circuit breakers in substations, switches along the feeder lines and on the loop points are needed to obtain a sactisified analysis result
提出一種通過饋線兩端的電壓和流過饋線兩端的開關的功率反映饋線上的負荷及其分佈情況的配電網的簡化分析方法,這種方法只需對變電站的出線開關、饋線的分段開關和聯絡開關進行量測,而不必量測饋線上的配電變壓器,就能得到滿意的分析結果。The basic software consists of topology analysis, on - line load flow computation, state estimator, security analysis, dispatchers training simulator, short circuit current computation, and voltage / reactive power optimize, etc. the derived softwares consist of load control, capacitor optimizer configuration, transformer and feeder load distribution, impedance computation of generator, etc. network analysis software is powerful dispatch tool, though witch the current state of the power system can be realize, then improve the security and economic potential
Dms網路分析的基本軟體有:網路結線分析、潮流計算、狀態估計、負荷預報、短路電流計算、電壓無功優化等。派生軟體有:負荷控制、電容器優化配置、變壓器與饋線負荷分配、電源阻抗計算等。網路分析軟體是有力的調度工具,通過它可以了解和掌握當前的運行狀態,從而挖掘安全和經濟方面的巨大潛力。The reactive power optimization compensation is to find the suitable compensation place and the best compensation capacitance by adjusting the generator bus voltages, transform taps and reactive compensation capacities in the condition of satisfying power load requirement, which can guarantee the secure and high quality power for consumers. the improved genetic algorithm is applied in this thesis according to the features of reactive power optimization of high voltage transmission bus, which are the non - linear problems with multi - variables and multi - restrictions
電網無功優化補償是在有功潮流調度給定的情況下,以負荷節點電壓和線路輸送無功功率作為狀態變量,運用優化演算法,調節發電機節點電壓、變壓器可調分接頭和無功補償裝置,在滿足電力負荷的要求下,尋求合理的無功補償點和最佳補償容量,保證電網能夠安全、優質地向用戶供電。By analyzing the load factor and unbalance factor of distribution transformer, the method of calculating and selecting the low voltage reactive power compensation capacity and compensation equipments, and the connection mode of capacitors were presented
摘要通過對配電變壓器負載率和不平衡率的分析,提出低壓無功補償裝置補償容量的計算選擇方法和電容器的接線方式。Because the harmonics in tangyin substation are primarily from electric traction loads, this paper gives the structures of several main locomotive models and general harmonics they produce. the harmonics produced by electric locomotive have a characteristic that their range and phase are both dispersive. this paper also analyzes the impedance - matching balance transformer ' s structure and harmonics injected into the power system at its primary side, and sums up the characteristics of the harmonics from electric traction loads in the tangyin traction substation
鑒于湯陰變電站的諧波主要來自電力牽引負荷,本文列舉了電力機車幾種主要車型的結構以及它們產生諧波的概況,得出了電力機車的各次諧波電流幅值和相角具有較大分散性的特點。針對湯陰牽引變電站的牽引變壓器,分析了阻抗匹配平衡變壓器的結構及其高壓側注入電網的諧波,推導了有關計算公式。通過理論分析並結合湯牽線的實測諧波數據,歸納了電力牽引負荷注入湯陰變電站的諧波的特點。By close study on the average temperature rise, temperature distribution, and tune constant of the class f resin dry type power transformer ' s high voltage and low voltage winding under self - cooling and wind - cooling mode, we find out the connection between the variation of the load and the items, mentioned above. the results of the experiments can be reference to both thermal design optimization of dry type power transformer and the revision of current standards. meanwhile, we develop the software, which can predict the overload ability of the dry type power transformer
本文對f級樹脂澆注式乾式變壓器的高、低線圈的平均溫升,內部溫度分佈和時間常數在自冷和風冷,兩種冷卻方式下隨負載變化的規律進行了研究,得出了平均溫升、熱點溫升和時間常數隨負載變化的相互關系和有關計算用參數和公式,試驗結果可作為改進乾式電力變壓器的熱設計的依據和對現行標準進行修改的參考。Because of forecasting reactive load at first, it can detect the change of voltage at low - voltage bus from the change of reactive load or the change of voltage at high - voltage bus, then it can decide that adjusting transformer tap or capacitor switch, and avoid blindly and deficient adjusting. on the condition the reactive power is balanced and voltage qualified, it can realize the switching times of loaded taps and capacitors being efficiently decreased
由於預先預測出無功負荷,提前了解了無功功率變化的趨勢,可以有助於判定低壓母線電壓變化是由無功負荷變化引起還是由高壓側電壓變化引起,從而適時決定是調有載調壓變壓器分接頭還是投切電容器,以此避免了盲目和不充分的調節,實現在保證無功基本平衡和電壓合格率的前提下,減少有載調壓變壓器分接頭的調節和並聯電容器組的投切次數。Finally, a compact uwb pulse source composed of pzt95 / 5 ferroelectric ceramic, a 50 coaxial transmission line charged by a pulse transformer, a peaking - chopping switch, a coaxial matched load and a pulse diagnostic system was built and tested, which can produce pulse voltage on a matched 50 load with peaking voltage of 100kv, rising time of 870ps, falling time of 670ps, and fwhm of 1. 410ns
在上述工作的基礎上,我們研製了一臺以pzt95 5鐵電陶瓷沖擊去極化為能源的新型緊湊型脈沖發生器。該發生器由pzt9515爆電能源、空心脈沖變壓器、單同軸脈沖形成線、 pc開關、同軸匹配負載和脈沖診斷系統組成,能產生100kv 、上升前沿870ps 、后沿670ps 、脈寬1 4us的超寬帶脈沖。The impact of load characteristics and on load tap changer on static voltage stability is analyzed with the methods based on v - q and v - p curves, and the phenomenon of voltage stability voltage instability and voltage collapse are studied with steady - state simulation. finally the thesis presents the essential explanations of both voltage stability and the mechanism of voltage collapse. xu yonghua ( electrical engineering ) directed by prof
通過電壓?功率曲線分析法定性分析了不同負荷特性和有載調壓變壓器對靜態電壓穩定性的影響,並通過靜態模擬法從物理現象上研究了電壓失穩和電壓崩潰現象,最後針對這些現象給出了關于電壓穩定、以及電壓崩潰的本質解釋。That is, through analysis of the principle on flow control and " hydraulic transistor ", design and calculation of flow control characteristic as well as main parts in valve inner chamber, a piloted reducing valve will be installed between main valve and pilot valve. after a pressure - difference compensating reducing valve was added in the non - pressure compensating piloted reducing valve of the flow control valve in vlalvistor valve, the calculation on control characteristic emulation and load characteristic emulation has been carried out. the result of the calculation shows that after pressure compensating reducing valve was added, the linearity of the control characteristics has been greatly improved thus eliminating influence upon outlet flow by load pressure - change of the hydraulic system and improving performance characteristics of the hydraulic component
文章還在對瑞典valvistor閥的插裝比例閥研究的基礎上,提出了一種新的流量控制原理,即:通過對流量控制和「液壓晶體管」原理的分析、流量控制特性及閥內腔主要結構件的設計計算,在主閥和導閥之間增設先導減壓閥,並進一步對valvistor閥的流量控制閥之無壓力補償先導減壓閥、加入壓差補償減壓閥后的控制特性進行了模擬計算和負載特性模擬計算,結果表明:增設壓力補償先導增壓閥后,其控制特性曲線變得非常線性,從而消除了液壓系統負載壓力變化對主閥輸出流量的影響。Fault location is an importrant function in distribuiton automation. in the thesis, the transferred information from feeder terminal unit is computed with load ’ s trapezoid fuzzy figure. the fault location is affirmed by the result of computation using the trapezoid fuzzy math theory. the atp and matlab softwares are used to simulate the 10kv lines in urmuqi distribution network. and the results shows the reliability and accuration of the method in the thesis
線路故障定位是配電自動化的一項重要功能,文中提出利用線路始端電壓、電流和線路ftu (饋線終端單元, feederterminalunit )的上傳信息,結合配電變壓器負荷的梯形模糊數模型,運用模糊數學理論通過電流計算來進行故障定位的新方法。分享友人