起停電路 的英文怎麼說

中文拼音 [tíngdiàn]
起停電路 英文
start-stop circuit
  • : 起Ⅰ動詞1 (站起; 坐起) rise; get up; stand up 2 (取出; 取走) draw out; remove; extract; pull 3...
  • : Ⅰ動詞1 (停止) stop; halt; cease; pause 2 (停留) stay; remain; stop off [over]: 船在錨地停了一...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
  • 電路 : [訊] circuit (ckt); electric circuit; electrocircuit電路板 circuit board; 電路保持 guard of a c...
  1. 27th hkiff was not minimalist enough, kiarostami decides to completely dispense with dialogue, actors or camera movement in his latest. but far from being impenetrably austere, the iranian master has instead created one of his most poetic and humanistic works yet. each of the five zen - like static shots captures nature at its most glorious, from the driftwood washing up against the beach to the thunderous rumbles of rain upon the dark sea

    基阿魯斯達米去年完成的兩部數碼錄像影之一,是他海邊寫劇本時妙手偶拾的五個長鏡頭,長度十至二十多分鐘不等,分別是:一海灘一截木頭,隨潮來潮往二海邊上人來人往,偶爾駐足離開,浪濤不拍岸三冬日天空,大海,海灘大遠鏡,一群狗在遠方走動四鴨子一隻接一隻由左走向右,再聯群回頭向左走五晚上的池塘,偶見月光倒影,時而漆黑一片,只聞蛙聲此彼落,然後打雷閃下雨,最終黎明。
  2. This noncontact distributor assembly, which deletes mechanical breaker contact, utilizes ic ignition module assembly free of burn out of contact. therefore it has a higher ignition voltage, higher ignition volume, as well as functions of overvoltage protection, low speed & low voltage protection and power cut upon shut down. these functions are of benefit to improvement to the motive performance, economical efficiency and start up ability of engine while reduce waste exhaust

    該無觸點分器總成取消了機械斷器觸點,採用了集成組成的點火模塊總成,不存在觸點的燒蝕,因此點火壓高,點火能量大,並具有過壓保護、低速低壓啟動、車斷等多項功能,有利於改善發動機的動力性,經濟性和動性能,減少了排氣污染。
  3. Electronic soft starter is a kind of novel motor control device which can implement the soft - start, soft - stop and energy - saving of the asynchronous motor. compare in the traditional motor starter, it has outstanding advantages such as stepless regulation of the motor start, avoid the inrush of the torque and the current, and reliable protections, convenient operation and starting repetitively. so the paper aim at electronic soft starter, asynchronous soft starter of electrical machinery electron as research object, study it ' s high - performance soft starting technology - torque control soft - start, develop its realization circuit

    異步動機子軟動器是一種集機軟動、軟機、輕載節能和多種保護功能於一體的新穎機控制裝置,相比于傳統的動器,它突出的優點體現在能夠連續無級的調節動、沖擊轉矩和沖擊流小、控制簡便、動重復性好以及體積小等方面,本文以異步子軟動器為研究對象,研究高性能的機軟動技術- - -轉矩動方式,並研製其實現
  4. In case that the lease period is less than one ( 1 ) year, no matter whether at the request of the customer, or as a result of default in payment or violation of law, the customer shall be liable to cht for 35 % of the monthly rentals of port and pvc cir for the remaining period, in addition to the monthly rentals of domestic leased data circuit and dsu for the remaining minimum lease period in accordance with the leased circuit service regulations

    九、用戶租用本業務不滿一年即行拆機,不論是用戶申請退租、欠費,或違反法令而終止租用,其數據暨數位數據機月租費按國內數據契約條款有關規定計收未滿期間之租費,而通信埠暨固定通信之約定資訊速率月租費則按每月應繳費用總額百分之三十五計收自租日至租用后滿一年期間之各月租費。
  5. On - line monitoring of hvcb is the precondition of predicting maintenance, is the key element of reliable run, and is the important supplement to the traditional off - line preventive maintenance in fact, the faults are made by hvcb, no matter in number or in times, is over 60 % of total faults so it has determinative importance for improving the reliability of power supply and this can greatly decrease the capital waste used by - dating overhaul in this paper, the inspecting way of hvcb mechanism characteristic is discussed the concept of sub - circuit protector is presented, the scheme that we offered has been combined with sub - circuit integrality monitoring theory, to ensure that it has the two functions as a whole according the shut - off times at rated short circuit given by hvcb manufacturer, the electricity longevity loss can be calculated in each operation, and the remained longevity can be forecast too an indirect way for calculating main touch ' s temperature by using breaker shell temperature, air circumference temperature and breaker ' s heat resistance is improved in this paper, and main touch resistance can be calculated if providing the load current msp430, a new single chip microcomputer made by ti company, is engaged to develop the hardware system of the on - line monitoring device, and special problem brought by the lower supply voltage range of this chip is considered fully

    高壓斷器所造成的事故無論是在次數,還是在事故所造成的時間上都占據總量60以上。因此,及時了解斷器的工作狀態對提高供可靠性有決定性意義;並可以大大減少盲目定期檢修帶來的資金浪費。本文論述了斷器機械特性參數監測方法;提出了二次迴保護器的概念,並將跳、合閘線圈完整性監視和二次迴保護結合來,給出具有完整性監視功能的二次迴保護器實現方案;根據斷器生產廠家提供的斷器額定短流分斷次數,計算每次分閘對應的觸頭壽命損耗,預測觸頭壽命;提出根據斷器殼體溫度和斷器周圍空氣溫度結合斷器熱阻來計算斷器主觸頭穩態溫升的方法,並根據此時的負荷流間接計算主觸頭迴阻;在硬體設計上,採用美國ti公司最新推出的一種功能強大的單片機msp430 ,並充分考慮該晶元的適用壓范圍給設計帶來的特殊問題;在通信模塊的設計中,解決了不同工作壓晶元之間的介面問題,並給出了直接聯接的接線方案。
  6. The practical situations of system operations are considered in this paper. based on the enumeration of the cut sets for the load point interruption, load transition character, maintenance of devices, active failure mode and overload of transmission line are all discussed

    該方法考慮了系統運行的實際情況,列舉引負荷點事件割集,還考慮了負荷點供的轉移特性,網元件的計劃檢修和主動性故障使評估過程更加合理和有效。
  7. For the great amplitude, oscillation and long time lasted, galloping tends towards evoking the nasty accident of inter - phase shortcutting, damage to fitting and supporting structures, causing short - circuiting, conductor burned, hold down towers, and conductor broken, which engender serious economy damage

    因為舞動的幅度大,有擺動,一次持續很長時間,因此容易引相間閃絡、金具損壞,造成線跳閘或引燒傷導線、拉倒桿塔、導線折斷等嚴重事故,從而造成重大經濟損失。
  8. Stop lights at intersections weren ' t working in many places because of a power outage, causing confusion among motorists and considerable congestion

    由於龍卷風造成,許多十字口的指示燈無法正常工作,使得眾多汽車擁擠而引混亂。
  9. The practical situations of system operations are considered in this paper. based on the enumeration of the cut sets for the load point interruption, load transition character, maintenance of devices, active failure mode and overload of transmission line are all discussed. the evaluation is more realistic and effective

    該方法充分考慮了系統運行的實際情況,在列舉引負荷點供止事件割集的基礎上還考慮了負荷點供的轉移特性,網元件的計劃檢修和活動性故障,以及系統運行的過負荷約束等諸多情況,使評估過程更加合理和有效。
分享友人