起始出力試驗 的英文怎麼說

中文拼音 [shǐchūshìyàn]
起始出力試驗 英文
initial output test
  • : 起Ⅰ動詞1 (站起; 坐起) rise; get up; stand up 2 (取出; 取走) draw out; remove; extract; pull 3...
  • : Ⅰ名詞1 (最初; 起頭) beginning; start 2 (姓氏) a surname Ⅱ動詞(開始) start; begin Ⅲ副詞[書面...
  • : Ⅰ名1 (力量; 能力) power; strength; ability; capacity 2 [物理學] (改變物體運動狀態的作用) forc...
  • : 名詞(古代占卜用的器具) astrolabe
  • : 動詞1. (察看; 查考) examine; check; test 2. (產生預期的效果) prove effective; produce the expected result
  • 起始 : origin; origination; parentage; germ; initiation
  • 試驗 : trial; experiment; test
  1. In this thesis hydraulic experimental studies and theoretical analyses on the vortex - flow drop shaft were conduced and the following results were accomplished : ( 1 ) in the model test some hydraulic characteristics including the shape of air core in the center of the drop shaft, the radial distribution of water flow velocity and the distribution of pressure on the wall of the drop shaft were measured under the condition of high water head above 250m and large discharge above 1400m3 / s. ( 2 ) a kind of computational method for the spiral water flow in the air core region of drop shaft was discussed and applied and the results agree the experimental data well. ( 3 ) the total ratio of energy dissipation in the drop shaft can reach 90 % and the energy dissipation in every region was discussed quantitatively

    本文通過研究與理論分析對旋流式豎井泄洪洞應用於高水頭、大泄流量情況時存在的一些水學問題進行了研究和探討,取得以下主要成果:一、結合小灣工程導流洞改建,對高水頭( 252m ) 、大泄流量( 1400m ~ 3 s )條件下旋流式豎井中的水流運動特徵進行了比較全面的測量,包括空腔形態、徑向流速分佈及井壁壓強等;二、提了豎井空腔段螺旋水流水計算方法,其計算結果與實測值吻合良好;三、利用與計算結果,對旋流式豎井的消能機理進行了探討,對豎井各部分的消能能有了總體認識;四、對豎井下部消井的合理井深進行了優化研究,發現消井合理深度為0 . 9d左右;五、通過研究,歸納豎井水流總摻氣量估算方法,為導流洞排氣方案的設計提供了參考依據;六、在高水頭、大流量條件下,豎井空腔段下部流速很高,盡管水流螺旋運動引的離心可以確保井壁壓強保持正壓,但空化數依然較低,因此豎井的空化空蝕終是工程界關注的重大問題。
  2. In light of the limitation of fast fourier transform ( fft ) for the method of traditional spectrum analysis to analyze the unsteady signal, wavelet and wavelet analysis are made for the typical unsteady process signal of starting up and shut down with the good characteristic of simultaneous localization in both the time and the frequency domains based on the field test on the vibration of two - row placed units in lijiaxia hydropower station, in which the signal is decomposed into different frequency band, and then the weak signal is caught and the dominant frequency is picked up for the analysis of the vibration source

    摘要基於李家峽水電站雙排機組振動的現場研究,並且針對傳統頻譜分析方法傅立葉變換( fft )對于非平穩信號已不從心這一缺陷,利用小波分析方法在時域和頻域上同時具有良好的局部化性質,通過對開停機這一典型非平穩過程信號進行小波及小波包分析,將其分解到不同頻帶內,獲取微弱信息和提取優勢頻率,並對其作振源分析,得開停機初時刻因水流不穩均現強烈的振動現象,且低頻段信號能量最大,開停機過程水流脈動壓和尾水渦帶擺動是引定子基礎振動的主要原因。
  3. The paper is on how to set up lab platform of vapour spewing to uppercooling water surface to coagulate directly and to observe and analyse which vapour coagulate on the water surface, the results enable people to know the security system of nuclear power. the range of the pressure parameters of prz is from 0. 2mpa to 0. 6mpa, and the range of the initial temperature parameters of cmt is from 23. 5 to 78. 5, all of the testing points are 30 and there are fifty thousand testing data. many results of vapour spewing to uppercooling water surface vertically to coagulate can get. for example : coagulating can make the water of cmt surge forcefully when vapour spews to uppercooling water surface, too many vapour - bubbles come into being and strike the water of cmt owing to rupture continually, all these will strengthen the surge because of the vapour pressure of cmt

    中prz飽和蒸汽壓變化范圍為: 0 . 2mpa - 0 . 6mpa , cmt中水初溫度變化范圍: 23 . 5 - 78 . 5 ,實中測工況30個左右,實數據50萬余個,得了很多與非能動安全系統相關的蒸汽垂直噴向過冷水表面凝結時的結論:蒸汽垂直噴入過冷水表面凝結時會造成cmt中液面的強烈波動和振蕩,產生大量蒸汽汽泡,汽泡不斷破裂對cmt中液體帶來很大沖擊,勢必引cmt中液體的振蕩,造成cmt汽空間汽壓不均勻,加強cmt液體的振蕩和波動。
分享友人