The biggest actionable concern is time to recover from overload
最值得關心的是為了恢復超負荷壓力下的時間。This article aims at the boiler ' s problems in operation : 1 ) under nominal load, the smoke temperature at the outlet of hearth reaches 1200, far more exceeds 1050 the original designed temperature. this will always result in slag inside boiler and the temperature of overheater ' s pipe superheat, so that boiler cannot take nominal load and all these influence boiler ' s nomal operation heavily, 2 ) this article also studied the reason why the assistant oil becoming necessary when coal changes. during the nomal operation, many factors ( makeup of combustor and its disposal, smirch and encrust of water wall, excessive air coefficient, temperature of primary air, coal type and density of coal dust ) can deviate the designed working conditions, then affect the boiler ' s nomal operation
本文針對該鍋爐在實際運行中存在的問題:在額定負荷下,爐膛出口超溫、低溫段過熱器前煙溫高達936 ,遠遠超過815的設計值;噴燃器四周水冷壁結焦嚴重,過熱器管壁溫度超標,無法帶上額定負荷;甚至有時因燃煤質量的變化,必須投油助燃的嚴重情況進行了分析研究。在實際生產過程中,燃燒器的結構、布置,水冷壁的粘污、結垢,過剩空氣系數、一次風溫、煤種及其濃度變化等許多因素都會偏離鍋爐的設計工況,從而影響爐內的傳熱和燃燒,造成爐膛出口超溫、水冷壁結渣等問題。It shows that the injection quantity and the difference of temperature distribute as a parabola which is at the same load, and the minimum of the parabola corresponds to the optimum quantity of injection ( g ). under the condition that the quantity of injected mass, the air speed and the heat quantity is respectively g, v and q, the research demonstrates that the pentium iv chip ' s temperature variation can be controlled under 40c and work normally when the wind speed overpass 1. 5m / s and the power dissipation of the chip is 60w. otherwise this paper calculates the flooding limit of thermosiphon with several different methods
對其充灌量、散熱量、電子元件( cpu模擬晶元)表面與環境溫度之差及通風、流速的影響進行了系統的測試,發現充液量與溫差的關系在負荷不變時呈拋物線分佈,其極小值點對應的充液量是最佳充液量g 。在充液量為g時,對風速v 、散熱量q進行的研究表明,當風速超過1 . 5m / s后,奔騰晶元在60w發熱條件下晶元溫度小於40 ,能滿足長期正常工作。The over - current relay works to protect oscillation tubes and rectifier, when the current exceeds its limits. frequency deviation caused by faulty operation is also prevented
當電流超過限制值時,過負荷電流繼電器自動保護振蕩管和整流器,同時可以避免由不當操作所引起的頻率漂移。The numerical results indicate that the deformation within the solid inner core is very small. however, in the fluid outer core, the changes of the displacement with relatively low spherical harmonic degree ( n < 10 ) is very complicated via the radius, due to the resonance near the eigenfrequenies of the core long - period oscillations. while the spherical harmonic degree of the loading is larger than 10, the deformation and the gravitational perturbation in the core are very small, and the earth ' s deformation response is dominantly represented as the radial displacement in the elastic mantle
研究了地球在日月引潮力和表面負荷作用下的形變特徵,數值計算結果表明,在固體內核中的形變很小,由於在長周期核模本徵頻率附近的共振,液核中低階( n 10 )位移隨半徑的變化非常復雜,當負荷階數超過10時,地核中的形變和擾動位都很小,地球的響應主要表現為彈性地幔中的徑向位移,且隨深度增加急劇減弱,地表負荷love數與信號頻率的依賴關系很弱,給出了體潮love數計算的一種有效的近似處理方案。In chapter 4, for the first time, in the way of virtual malfunction simulation, cooling water of diesel engine type 4135 has been simulated under the stopping water supply malfunction. and the analysis and discussion has been taken on the result of transient temperature curve of the simulation. and in the same way, internally cooling oil piston of diesel engine type 180 has been numerically simulated on the virtual thermal loading mal
得出了虛擬其斷水故障模擬的瞬態溫度曲線結果,並對其進行了分析和探討;同時也用虛擬模擬的思想對180型柴油機內油冷活塞進行了虛擬其熱負荷故障的數值模擬,得出了其在斷油情況下和超負荷運轉情況下的分析結果。Over load working of transformers are guided by iec905 loading guide for dry type power transformers
按照iec905 《乾式電力變壓器負載導則》 ,是指導變壓器過負荷(超銘牌額定值)運行。This program can predict the wall temperature 、 internal wall heat tranfer coefficient 、 fluid temperature and entropy profile along the water wall. all of these provide an important foundation for designing this type of water wall structure to ensure the safety of the boiler operation. this hydrodynamic calculation program and the results can be used to analyze operation reliability and structure design of water wall system
利用所開發的程序對設計的超臨界cfb進行了計算,給出不同負荷下,水冷壁出口工質溫度分佈,水冷壁受熱面不同位置處的金屬壁溫、內壁放熱系數、流體溫度焓值分佈,以及不同管子的流動壓降等結果,為分析鍋爐工作可靠性及水冷壁系統的結構設計提供了重要依據。The temporal, spatial and frequency - field characteristics are discussed. the validity of the corresponding empiric formula is analyzed and the atmospheric effects and correction method are investigated in the data analysis of the ground - based observations. the atmospheric effects on the gravity observations are analyzed and detected using the gravity data recorded with the superconducting gravimeters at the global geodynamic project ( ggp ) stations
利用實測地面氣溫、氣壓資料獲得大氣負荷效應時間序列的數值結果,研究大氣影響的時間、空間和頻率特徵,分析經驗公式的有效性,研究地面觀測和數據分析大氣影響和改正的方案;利用ggp臺站超導重力觀測資料,分析檢驗大氣重力影響;分析igs臺站大氣位移改正的可能性Recommended practice for performing temperature rise tests on oil immersed power transformers at loads beyond nameplate ratings
超出銘牌額定值的負荷下進行油浸電力變壓器升溫試驗的推薦慣例With the expansion of reformation and opening policy, transportation trade in our country has developed very quickly. traffic is heavy and the load of vehicle is growing, which greatly exceeds the value of highway vehicle. so some roads have to be used over its design parameter and some bridges are damaged
隨著我國改革開放的不斷深入,交通運輸業有了突飛猛進的發展,公路交通量和汽車載重量日益增加,遠遠超出了當年的設計計算值,致使公路橋梁遭到了不同程度的破壞,但仍在超負荷使用,改造和加固這些超限服役的橋梁迫在眉睫,如何找出一條既合理,又省錢,又不斷交(省時)的加固方案,已是公路建設者們的一道課題。分享友人