輸出負載率 的英文怎麼說

中文拼音 [shūchūzǎi]
輸出負載率 英文
output factor
  • : Ⅰ動詞1 (運輸; 運送) transport; convey 2 [書面語] (捐獻) contribute money; donate 3 (失敗) l...
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 載Ⅰ名詞(年) year : 一年半載 six to twelve months; six months to a year; 三年五載 three to five ...
  • : 率名詞(比值) rate; ratio; proportion
  • 輸出 : 1 (從內部送到外部) export 2 [電學] output; outcome; outlet; out fan; fanout; 輸出變壓器 output ...
  • 負載 : [電學] load
  1. To the zvt - pwm soft - switching converter, not only the resonant parameters but the input and output voltage and the load can affect the converter efficiency. a detailed research of a typical zvt - pwm buck converter is done in this paper

    對zvt - pwmbuck變換器而言,除了諧振參數對工作效有很大的影響外,變換器電壓和所帶對工作效都有影響。
  2. Based on the study of transferring characteristics of the lcc - type resonant voltage, the parameter combinations, which make widths and magnitudes of voltage pulses of resonant network adjustable, arededucedo when the following requirements are met : fn > 3, k > 3 or cp / cs > 8, the above circuit is of natural voltage - stabilized characteristics, thus open - loop control method for bucking voltage is presented and the experimental results verify that the method is feasible.,

    實測整機在額定時效達到88以上。在研究lcc諧振網路電壓傳特性的基礎上,推導滿足可變寬度和幅度的諧振網路電壓脈沖列的參數組合。設計f n 3 、 k 3或c _ p / c _ s 8時,諧振網路具有自然穩壓特性,因此本文提並實驗驗證了一種整機為降電壓時的開環控制策略。
  3. 1 m 0. 5, the phase - shifted angle 6 is controlled in term of sine law which makes the magnitude of resonant voltage track a reference sine voltage, and the resonant voltage is rectified, filtered, inverted and then the better sine - voltage output is obtained, theoretical analysis and experimental results show that for the resistive load and inductive load, the switches of leading leg of the phase - shift - controlled circuit are always turned on at zvs, and ones of lagging leg are turned on at zvs ( < 0 ) or turned off at zcs ( ( > 0 ), moreover, all switches in the low - frequency inverter are always turned on and off at zvs, the measured circuit efficiency for rated load reaches up to 88 %

    從功單向流動角度發,提了一種lcc諧振型恆頻移相單相高頻鏈逆變電路拓撲,在調制系數0 . 1 m 0 . 5情況下,控制移相角按正弦規律變化,使諧振電壓脈沖列的幅值追蹤參考正弦電壓信號,經過整流、濾波、低頻逆變,從而獲得正弦度較好的電壓。理論分析和實驗結果證明對于阻性或阻感性,移相全橋具有超前橋臂零電壓開通,滯后橋臂或者零電壓開通( _ 0 )或者零電流關斷( _ 0 )的軟開關特性,而低頻逆變器的各個開關均實現零電壓條件下的開通與關斷。
  4. The harmonic circulating current balancing is an important factor in the parallel operating control for it makes the units of the system to get. an equal power factor and makes foundation for the system to work stable and reliable

    並聯電源系統的諧波環流均分控制是實現的失真功均分,保證各並聯單元的因數均衡,保證並聯系統穩定可靠工作的一個重要方面。
  5. In view of this situation this article has conducted research to the design of metallurgy auxiliary biography with the frequency conversion table electrical machinery first multianalysis to the frequency changer and the frequency conversion table electrical machinery movement characteristic is carried out, the voltage waveform harmonious which the frequency changer outputs is big, attacks in a big way, and the voltage climbing rate reaches as high as 6600v / mu s which is 20 times ordinary sine alternating voltage, the rolling mill auxiliary biography table set the extremely strict request to the electrical machinery ; its movement frequency is very low, rate frequency in 8 - 20hz ; the velocity modulation scope is wide, the lowest movement frequency lowers to 1hz, and the starting number of times is quite frequently, each hour reaches as high as 600 - 800 time, the impact shoulders in a big way, the overload capacity request is high

    針對這一情況本文對冶金輔傳用變頻輥道電機的設計進行了系統研究。首先對變頻器和變頻輥道電機的運行特性進行詳細分析,變頻器的電壓波形諧波大,沖擊大,電壓上升高達6600v / s ,是普通正弦交流電壓的20倍;軋機輔傳輥道對電機提了十分嚴格的要求:其運行頻很低,額定頻在8 - 20hz ;調速范圍寬,最低運行頻低到0 . 5hz ,起動次數相當頻繁,每小時高達600 - 800次,沖擊荷大,過能力要求較高。
  6. Thirdly, it simulated the pumping circuit & dividing circuit with the widely used software matlab / simulink. the displacement of the rod piston and the impact of hydraulic are analyzed in the different input flow ( frequency of pump ) and different reversing time. it found out the cause of hydraulic impact ( one - to - one incorrespondence between the response time of dividing circuit and the operation time of rod piston ), and gave some methods to weaken hydraulic impact. in the final part of the paper, the reliability of the theory analysis is further verified by the experiment of hydraulic system

    首先在流變學原理的基礎上,深入分析混凝土在送管道內的流動狀態,得混凝土泵的特性方程;然後根據功鍵合圖的建模方法,建立泵送迴路和分配迴路的數學模型,並運用模擬軟體matlab simulink對泵送和分配迴路模型進行了模擬,分析了在不同的入流量(泵送頻)和換向時間下,活塞桿的位移和系統的液壓沖擊情況,找到了引起液壓沖擊的根本原因(即分配迴路的響應時間(固定值)與活塞桿的運動時間(變化值)不相匹配) ,並提了相應的改進方法。
  7. The methods that can efficiently suppress the disturbance on gate of switching component of the inverter - bridge are synthesized. a dual - inductor output filter is employed to improve electromagnetic interference ( emi ), due to turn - on or turn - off of the power switches of the inverter, which may be lead loads into trouble

    本文詳細論述了1kva25hz新型鐵路信號電源和2kva高頻在線式ups的設計和調試工作,總結了幾種能夠有效抑制逆變橋功開關管門極干擾的措施,並且運用一種雙電感結構的濾波器來改善由逆變器功管在開關過程中產生的、影響設備正常工作的電磁干擾。
  8. The typical performance characteristics include : line and load transient response, efficiency, output voltage ripple, quiescent current, maximum load current, output voltage temperature characteristics and the short

    其中,整體模擬指標包括:晶元線性調整調整、轉換效電壓紋波、晶元靜態電流、最大電流、電壓溫度特性及短路電流。
  9. The programme logic controller is utilized to control the inverter ' s output frequency which accomplishes controlling the velocity of speed - controlling asynchronous moter. the velocity between main asynchronous moter and speed - controlling asynchronous moter is composed by way of the differential planetary gear train, the tranmission system is made to regulate velocity stepless in large scope which succeed in controlling starting progress of load

    使用可編程式控制制器對變頻器的進行控制,實現對調速電機轉速的控制。調速電機與主電機的轉速經差動行星輪系的速度合成,可使傳動系統在很大范圍內無級調速,實現對的可控起動。
  10. Dc input voltage ; output voltage ; frequency ; load capacity

    直流入電壓,交流電壓,頻容量
  11. This project makes some researches with emphasis on the mv / lv distribution power supply situation under the present load condition. some results such as the calculation of line load rate, theoretical line consumption rate and electric voltage decrease are acquired by the mathematical analysis, and thus the power supply capability is evaluated comprehensively. the same has been done to the lv power network

    課題在系統搜集分析蘇州供電企業的背景資料,即企業概況、電力需求、電網、高壓配電網狀況基礎上,重點研究了當前荷下的中低壓配電網供電情況,並通過數學分析得線路的的計算、理論線損以及電壓降等各項運行指標,綜合評估得其供電能力。
  12. The simulated test of the mechatronics soft start equipment is made regarding the experimental platform of belt conveyor as load, the sensor design is had for selecting type, the testing datum are gatherd and analyzed, the rational curve of velocity in the starting and braking progress are gained, the best matching ratio of driving power for the double asynchronous moters is found

    以帶式送機實驗臺為進行了機械電子式軟起動裝置的模擬試驗,對傳感器進行了選型設計,對試驗數據進行了採集與分析,確定了合理的起、制動速度曲線,求雙電機驅動功的最佳配比。
  13. It is evident from above two expressions when the btl circuit and the ocl circuit operate under same power supply voltage and same load, the output power of the former is four times of that for the latter

    對比以上二式不難看:橋式電路和單端電路在電源電壓和相同條件下,前者的為後者的四倍。
  14. The result shows that, when the full - bridge power converter is joined with boost / buck dc chopper in parallel, it can serve a dc voltage of over 340v and a power of 800w, meanwhile, as output voltage of the fuel cells changes due to loadings, the sliding - mode controller can cause more rapid responses and robustness to the dc bus voltage source

    實驗結果顯示,本論文之全橋式功轉換器與升壓/降壓直流截波器並聯供電時,電壓可達340v以上,約為800w ,同時,當燃料電池之電壓因而改變時,本論文所提之滑動模式控制器能使直流鏈電壓具有較快速的響應及強健性。
  15. These topologies of inverters are composed of two bi - boost dc / dc converters, they are symmetry. so whole circuit turn into four - quadrant converters, we can control every power mosfet on or off. then we can get sine wave with direct current polarization at the left, at the same we also can get sine wave with direct current polarization phase contrast 180 compared of the left at the right

    這類逆變器由左右二個雙向boostdc / dc變換器構成,左右二邊是對稱的,所以整個電路構成了一個四象限變換器,我們可以恰當控制各功管的開、關,使左邊的兩象限dc / dc變換器一個帶直流偏置的正弦波,使右邊的兩象限dc / dc變換器一個相差180度帶同樣直流偏置的正弦波形,這樣,zl上的電壓是左、右兩個dc / dc變換器電壓的差動,正好可以消掉直流偏置,最終在r1上得到的就是正弦波。
  16. The simulation results show that the power factor and efficiency of lim are much lower than that of rotary induction motor due to end effect and big air gap of lim. end effect force has a great influence on the thrust of lim. the performance of lim can be improved with the proper secondary structure, small air gap, big goodness factor or heavy load

    結果表明:受邊端效應及大氣隙影響,直線感應電機功因數及效較低;運行狀態下的邊端效應力對電機推力有較大影響;設計電機時選用合適的次級材料、減小氣隙、增大品質因數、增加都可提升電機的性能,通過設計有效的控制演算法可使電機在額定滑差下具有較高的運行效
  17. The ic modulation circuits and microprocessor are used in the control unit. on the side of input of inverter, the maximum power point tracking of solar module is well realized by using a kind of thought of self - optimizing control ; on the side of output of the inverter, a kind of approximate optimum v / f control strategy is used in order to optimize the match between the output of the inverter and load of motor - pump

    在逆變器入側,採用自尋優控制思想實現太陽能電池最大功點跟蹤( mppt ) ;在側,採用了v / f近似優化的控制策略,以優化逆變器與機泵之間的匹配。
  18. The inverted pwm changing electric current the technique is applied in the prototype model. the prototype model was tested and operated on spot, power factor could reach beyond 0. 95, the effect of following modulating voltage was better, the curve of factor of modulated voltage of exchanging systems changed following load rate was linear, the output of wave form was a flat and steady sinusoidal wave

    樣機採用了逆變式pwm變流技術,對其進行了現場測試與試運行,測試結果是電網側的功因數可達0 . 95以上,跟蹤調壓效果良好,變流系統調壓系數( k )隨( p )的變化曲線基本滿足直線關系,波形呈平滑穩定的正弦波。
  19. The open voltages and power outputs of graded materials are much higher than monolithic materials, and when the length was kept at 15 : 2, the maximum values were achieved. the measured maximum power outputs of graded materials is about 320 wm " 2 when the loaded is fixed at 0. 1, which is about 1. 8 times than that of cosbj compounds ( 178wm " 2 )

    Sb :熱電材料具有最大的開路電壓和功;梯度熱電材料bizte3 / cosb3在外界為0 . iq時的功約為32owm 「 ,約為均質材料cosb3功178wm一2的1
  20. For the cell working range ascertainment, the algorithm determines the maximum output load, the minimum output load, the maximum input signal slope and the minimum input signal slope ; for the cell working surface representation, the algorithm inserts the characterization points dynamically. the table optimization algorithm for redundantly characterized points is proposed. its result table can represent the whole parameter surface accurately and concisely

    通過計算單元在各測試狀態下的最大、最小入信號的最大、最小斜,演算法能精確計算單元的工作曲面范圍;通過參數測試點的動態插入,演算法能獲得最佳的參數測試點,最大程度地表徵整個參數曲面空間。
分享友人