送風端 的英文怎麼說
中文拼音 [sòngfēngduān]
送風端
英文
lancing end-
For instance, emerson company intends to make guangdong province its largest base of undertakings in china and will carry out such undertakings as logistics, finance and housing in guangdong province. the edf expressed its desire to broaden its cooperation with guangdong province in terms of power construction
據傳公元1042年在包公離任途中,本來風和日麗,但船過羚羊峽卻風雲突變,烏雲翻滾。包公感到事有蹊蹺,經查有個紳士送的端硯放在船上。包公當即將端硯拋到江里。The zone supply and return air paths are used to describe the configuration of the flow path that the supply air takes in moving from the main air handler to the zone terminal units and that the return air takes on leaving the zones and returning to the central return air duct
空調區域的送風和回風路徑用於描述,送風從主要空氣處理設備到區域終端設備和回風從空調區域到集中回風管道的過程。Paper rolling machine indicator ( three colors, with beep ), wire collecting machine, with or without terminal, terminal overload sensor wire feeding machine ( wrs20dr ) terminal track not cutting machine, cooling fan for crimping machine, 1mm stripping corresponding knife
卷紙機,表示燈( 3色,帶蜂鳴) ,皮帶收線機,端子有無,端子過負荷感應器,送線機( wrs20dr , )端子履帶不切斷裝置,壓著機冷卻風扇, 1剝皮對應刀。There is no thoroughly rounded theory about displacement ventilation system in our country at present and our research begins recently. the study work of this paper will be useful for further optimization design of displacement ventilation system. this dissertation includes five parts. the first part introduces the development of the displacement ventilation and the background of research in domestic and oversea. in the second part, it gives working principle of displacement ventilation system and it ’ s advantages to the mixture ventilation. the study also gives a series of indexes to evaluate displacement ventilation system and specifies air supply terminal device and so on. it is needed to simulate and analyse the velocity field, temperature field and distribution of flow field. this is the third part. the forth part specifies the simulative method for thermal stratification of displacement ventilation system. it gives some factors affecting thermal stratification height such as inlet temperature, inlet velocity, heat transfer of wall body, distance of heat source and so on
本文的研究工作主要包括以下幾個方面的內容: ( 1 )綜述了國內外相關的研究現狀和研究背景; ( 2 )簡介了置換通風的工作原理,並分析了它相對于混合通風的優良特性及評價指標、末端裝置等; ( 3 )對採用置換通風方式房間的溫度場、速度場和氣流分佈進行了模擬計算與分析; ( 4 )對採用置換通風方式房間的熱力分層高度進行了模擬計算,並分析其影響因素,如:送風溫度、送風速度、圍護結構傳熱和熱源分佈等; ( 5 )擬合了無量綱熱力分層高度相應于送風溫度t 、送風速度v 、熱源間距離l和圍護結構傳熱q的經驗公式。The experiment ' s results show that the system is stable under the static pressure control and energy saving under the minimum total supply air volume control. although the terminal dampers ' s tuning time is prolonged under the minimum total supply air volume control, it can be reduced by adopting the appropriate sampling time when debugging the system. from all of this we can conclude thart the minimum total supply air volume control has a good application perspective
實驗結果表明,定靜壓控制方式下系統較為穩定,最小總送風量控制比定靜壓更加節能,但它延長了末端閥位的調節時間,在系統調試時,我們可通過選擇合適的采樣時間來縮短閥門的調節過程,所以最小總送風量控制具有廣闊的應用前景。Ventilation at one end of vault is accustomed used in main workshop of underground hydropower station, the flux uniformity of the outlet influences how the basic network cell model - - - - blast vault should be established in network simulation
地下電站主廠房常採用拱頂一端送風進行送風,其各個風口的送風均勻性直接關繫到主廠房送風拱頂這一網路基元在網路模型中應如何圖化。The paper studies the the flux uniformity of the outlet when ventilates at one end of vault in the main workshop of xiluodu underground hydropower station via the method of numerical simulation cfd, puts forward means which can achieve symmetrical ventilation, validates the cfd results credibility by the way of model experiment afterward
本文採用cfd數值模擬的方法對溪洛渡地下電站主廠房拱頂一端送風的均勻性進行了研究,提出了實現均勻送風的手段,然後用相似模型實驗進行了驗證,並據此提出了均勻送風拱頂與非均勻送風拱頂的網路基元模型。As new terminal equipment in air - conditioning, the mechanism of radiant floor is heating or cooling the room mainly through radiation and convection
輻射地板作為一種新型空調末端設備,主要利用輻射和對流形式對房間供冷或供暖;與常規空調送風相比,具有熱舒適性好、節能、美觀、對環境影響小等優點。分享友人