When measuring the magneto performance parameter , we find that the instrument which use to measure voltage and current is still the simple voltmeter and amperemeter in the national standard , and the form of wave that we observed is anomaly. based on the measure principles, it obviously ca n ' t be used to do quantitative analysis ; because the discharge process of ignition system is quite complex, accompanies with very strong electromagnetism interference, and the ignition current and voltage are variable , it make the measure of ignition energy become a difficult thing of ignition system performance detection
在磁電機常規測量時,發現在國家標準中用於測量電壓、電流的儀器仍然是普通的電壓、電流表,而觀測到的波形多為不規則的形狀,根據測量原理,顯然不能用其來做定量的分析;由於點火系統的放電過程比較復雜,伴隨著很強的電磁干擾,點火電流、點火電壓都是變量,使得點火能量的測量成為點火系統性能測試的一個難點。Seven test points enable a check of the output voltages and currents, by supplying proportional voltages relative to gnd
七個測試點通過對地的比例電壓能夠間接測量出輸出的電壓和電流。At the same time, combining the electrostatic measurement principle and the actual working conditions of pneumatic pipelines, the author puts forward the design principle in theory and finishes the devising, executing, debugging, experimenting and analyzing the experiment phenomena and results, testing the feasibility of the electrostatic sensor to be used in the measurement on the mass flow rate of the coal paniculate. furthermore, with the debugging and experimenting of the system, the author improves the electrostatic sensor and its signal collecting system gradually according to the problems, and makes the performance of the system to be enhanced remarkably
同時,作者結合靜電測量原理以及氣力輸送管道的實際工況,從理論上提出了靜電傳感器的設計依據,完成了靜電傳感器及其信號採集系統的設計、製作、安裝、調試和實驗,分析了實驗現象和結果,驗證了靜電傳感器用於煤粉質量流量測量的可行性,並且通過系統調試和實驗,針對發現的問題對靜電傳感器及其信號採集系統不斷地進行了改進,使其性能有了顯著地提高。However, one of the most serious impediments to wider use and improve precision of psi is its sensitivity to external vibration with the consequence that psi has rarely been used in a manufacturing in - situ and some special situations, such as that the optical path is very long or the detected unit is very large
通過嚴格控制環境條件(溫度、氣流、振動等) ,其理論光程差(位相)的最小解析度可以達到nm的數量級。然而,由於干涉計量測試靈敏度高、精度高,對外界振動非常敏感,使它的應用范圍受到限制。The measurement of oil / water two - phase flow is primarily accomplished by the combination of total flow rate and holdup measurement, and at present, the rotator flowmeter is used to measure the total flow rate. since the rotator flowmeter has movable parts, which makes its responsibility behave nonlinearly under poor environment of me under hole whose fluids have very complex and changeful characteristics and affects the measurement precision. what ' s more, the widely used centralized measurement instrumentation meets problems in oil wells characterized with high production or high water cuts
通常油水兩相流測量主要是通過總流量和持率的測量組合來完成的,目前在總流量的測量中主要使用的是渦輪流量計,由於渦輪流量計具有可動部件使其在流體特性復雜多變的惡劣井條件下的響應呈非線性變化規律,影響測量精度,此外,普遍採用的集流型測試儀器在高產井及含水率高的油井中使用也遇到困難,為此,一種新型的適合非集流型點測的測試方法和測試儀器亟待發展和推廣。Whole scheme of frame design of testing flat is proposed as : the host fanner supply the air required by flamer ’ s burning and cooling, the export parameter of the flat varies by different rotate speed of the fanner 、 angle of the fan inlet and the quantity of oil, the measurement of flow in the testing flat adopts the method of fanner dynamics performance test in the nation criterion
確立了實驗臺結構設計方案:主風機為燃燒器提供燃燒所需的一次、二次進風量及冷卻風量;模擬實驗臺出口煙氣熱流量是通過調節風機的轉速、風門開度及燃油量來改變;實驗臺的流量測量採用風機動力性能測試標準中流量方法等。Research on water hammer with gas in pressure conduit system through physical experiments, researches on pressure conduit system with gas releasing and liquid column separating, which consist of observing flow patterns, testing the conditions under which liquid column separation brings into existence and the water hammer in water interception collision, and studying effects resulting from gas content and different water velocities in pipeline, was done
3 、輸水管道系統中含氣水錘研究通過物理試驗,對有壓輸水管道系統中的氣體釋放與液柱分離進行了研究,觀察其流態、測試液柱分離發生的條件及斷流彌合水錘壓力,研究了含氣量、流速等參數對液柱分離的影響。With the experiment, the author believes that electrostatic transducer technology has several characteristics as the new means of mass flow rate measurement technique : its structure design is very novel and can be prone to be installed, it is more suitable for the measurement on the mass flow rate of the coal particulate in larger caliber pipelines and has higher delicacy in the measurement on both dilute and dense phases
通過實驗,作者認為靜電傳感技術作為一種新興的質量流量測量技術具有以下特點:靜電傳感器結構設計新穎,易於安裝,適合於大口徑管道中煤粉顆粒的質量流量測量,對稀相及濃相測試均具有較高的靈敏度。When in experiment, the air was heated by the film heater installed on the above and below surface of channel, adopting various air velocity of flow, test import ' s and export ' s temperature, wall temperature, fluid flux and the drop of pressure, and the other parameter. adopting nu and nu0 to analyze the baffle ' s situation of heat transfer and fluid flow, which baffle was holed various diameters
實驗時,通過矩形通道上下壁面敷設的電加熱膜加熱通道空氣,改變空氣流速,測試不同工況時的進出口溫度、壁面溫度、流體流量和壓力損失等參數,並採用無量綱努謝爾特準則數nu 、 nu _ 0等分析了設置不同開孔折流板的換熱與流動情況。The results show that while the mass flow of refrigerant is 1. 85g / s, the inlet temperature of refrigerant is 18. 9, the evaporating pressure is 0. 62mpa, the mass flow of water is 31. 1g / s, and the inlet temperature of water is 36. 9, the refrigerant of miniature evaporator wholly vaporizes in the tube, and the heat transfer rate is 342w. it achieved the demand of design
經過實驗測試,當製冷劑質量流量為1 . 85g / s ,製冷劑入口溫度為18 . 9 ,蒸發壓力為0 . 62mpa ,水的質量流量為31 . 1g / s ,水的入口溫度為36 . 9 ,此時,螺旋管蒸發器內製冷劑完全蒸發,換熱量342w ,達到了微型蒸發器的預期設計要求。4. during the investigation of distinction in mathematical cognitive structure, the author uses statistical sampling method. by test - analysis, observation, conversation and exchanging with teachers, the qualitative and quantitative analysis is made
在對高中生數學認知結構個體差異的調查研究中,筆者首先採用整群+分層抽樣的統計方法選取了樣本,然後通過問卷測試?分析法、觀察法、談話法以及與數學教師的交流對調查結果做出了定量和定性的分析。This experiment include many contents, in a word, that is summer condition experiment, winter condition experiment > summer - winter transition condition experiment and winter - summer transition condition experiment, furthermore summer condition experiment still include flux changing experiment and winter condition experiment still include thermal balance experiment this article dealt with the data of the test, calculating out energy absorbing ( energy discharging ) of buried pipe in winter condition ( summer condition ), input power of heat pump x heat exchanging of piece buried pipe length x co - efficiency performance ? op ( energy efficiency rate ? er ) and average heat exchanging coefficient ; in additiont this article compares the inlet water temperature and outlet water temperature of underground the first layer and the second layer buried pipe when heat pump was running, the results are that the heat exchanging ability of the second layer buried pipe outgos the first layer buried pipe, and heat exchanging is more stable ; and still analyse earth temperature resuming in the transition season. the results are earth temperature resume fast in the first week when the heat pump runs off
本文測試內容相當多,概括地說就是四個工況的測試,即夏季製冷工況的測試、冬季供熱工況的測試、夏?冬過渡季測試和冬?夏過渡季測試;另外在夏季工況的測試中還進行了變流量測試,在冬季工況的測試中還進行了熱平衡測試。本文對測試數據進行了處理,計算出了冬(夏)季工況埋管吸(放)熱量、熱泵空調器供熱量(製冷量) 、熱泵空調器輸入功率、埋管單位管長換熱量、供熱性能系數(製冷能效比)和平均傳熱系數等;另外,還比較了熱泵運行時地下一二層埋管進出水溫度變化情形,得出地下二層埋管換熱能力優于地下一層埋管,且換熱很穩定;並分析了過渡季地下一二層埋管溫度恢復情形,得出熱泵系統停機一周內地溫恢復特別快。Aiming at the structure characteristics of the pipeline system of the existing boiler combustion equipment, the paper work out the new - style air speed measure components via the theory analysis of the existing measure components of all kind of forms and measure theory. and then the paper designs and builds the wind tunnel test - bed to process the test and research of the air speed measure components in order to realize it ' s structure and each characteristic parameter
針對現有的鍋爐燃燒設備管路系統的結構特點,論文通過對現有的各種形式、測量原理的流量測量裝置的理論分析,設計出新型的風速測量元件,並且設計、建立滿足試驗所需的風洞試驗臺,對風速測量元件的結構及各項特性指標進行試驗研究,完成一次元件的開發工作。The differential pressure across the pressure test points is measured and the flow rate calculated using the calibrated chart or flow coefficient table
測量經過壓力測試點的壓差,並利用標準化圖表或流量系數表計算流動速率。Method of testing flow capacity of suction line filters and filter - driers
吸液線過濾器和濾器乾燥器的流量測試方法Secondly, the modification function and resonance produced by running power capacitor increased the harmonic at the same time, which worsen the operation environment of itself. it is very important to analyze the reason of harmonic and conduct the valid measure to restrain its affect and guarantee the safely operation of power network. the author has present the point in this paper, based on the operation characteristic of modern power system, the author described the production and development of network harmonic with the consideration on the same kind of problem
本文以現代電力網路的運行特點為基礎,結合近年來對所涉及的同類問題的思考,對系統諧波的產生、發展的一般規律進行較為全面的理論闡述;以大量事故案例分析諧波所帶來的危害和影響;通過實地測試和對所得數據的分析研究,推導出一種應用matlab的fft的諧波分析方法,給出了該方法的程序流程框圖及結果界面顯示;在此基礎上進一步探討了利用現代通信網路建立電網諧波網路管理分析系統的總體構想和功能。The trim valves of the confirming flow test
應該確認這些閥門通過流量測試。Method of test for amount of material passing test sieve 75 mum in aggregates
集料通過75 m試驗篩總流量測定的試驗方法After several tests, it is showed that the system is reliable, flow measurement is accurate, and data ' s confidentiality and the system ' s anti - interference functions are very strong
通過試驗,該智能渦街流量計系統運行可靠,流量測量準確,數據的顯示清晰明了,系統數據保密性能和抗干擾能力強。Calibration of a single range dc insulation resistance tester for one output voltage ( normally not exceeding 5 test points )