鉗位電流 的英文怎麼說

中文拼音 [qiánwèidiànliú]
鉗位電流 英文
clamp current
  • : Ⅰ名詞1 (鉗子) pincers; pliers; tongs 2 (姓氏) a surname Ⅱ動詞1 (夾住) grip (with pincers)...
  • : Ⅰ名詞1 (所在或所佔的地方) place; location 2 (職位; 地位) position; post; status 3 (特指皇帝...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. Based on the thorough investigation of the post - regulation and efficiency in multiple output switching - mode power supplies, an optimal combination topology for multiple output switching converter is presented in this thesis, which is consisted of forward converter with active clamp ( fac ), synchronous rectification ( sr ) techniques and magnetic amplifier technique ( magamp )

    本文通過研究分析近年來多路輸出開關源輔助輸出壓調節和提高效率的方案,面對開關源朝著輸出低壓大方向發展的趨勢,提出多路輸出開關源新的拓撲優化組合模式? ?有源正激變換器、同步整技術、磁放大器。
  2. It is necessary to control the mechanical stimuli precisely in the studies of cardiac mechano - electrical feedback ( mef ). in the present study a ventricular pressure - clamping system has been developed, which can be applied to isolated - perfused rabbit hearts. controlled by a computer, this system not only can make the left ventricle follow a command defining the same pressure wave as that during a beating cycle under physiological condition, but also deliver mechanical stimuli with a proper waveform to the ventricle at a particular time phase. this system integrates multiple functions, including perfusing, pacing, recording of electrocardiogram and monophasic action potentials, and clamping and measuring of ventricular pressures in isolated - perfused hearts. thus, it is a distinct system for investigating the phenomena and mechanisms of cardiac mef at organ level

    在心臟機械反饋的研究中準確控制機械刺激是非常重要的.本研究室構建了一套適用於離體家兔心臟的心室壓力系統.該系統通過計算機控制壓力,不僅能模擬正常生理條件下左心室的壓力波形,還能在心室活動周期的特定時相、以適當波形對心室施加機械刺激.該系統集心臟灌與起搏、表面心圖記錄、單相動作記錄、心室壓力制與測定等多種功能於一體,特別適用於器官水平上觀察機械反饋現象並探討其機制
  3. Abstract : it is necessary to control the mechanical stimuli precisely in the studies of cardiac mechano - electrical feedback ( mef ). in the present study a ventricular pressure - clamping system has been developed, which can be applied to isolated - perfused rabbit hearts. controlled by a computer, this system not only can make the left ventricle follow a command defining the same pressure wave as that during a beating cycle under physiological condition, but also deliver mechanical stimuli with a proper waveform to the ventricle at a particular time phase. this system integrates multiple functions, including perfusing, pacing, recording of electrocardiogram and monophasic action potentials, and clamping and measuring of ventricular pressures in isolated - perfused hearts. thus, it is a distinct system for investigating the phenomena and mechanisms of cardiac mef at organ level

    文摘:在心臟機械反饋的研究中準確控制機械刺激是非常重要的.本研究室構建了一套適用於離體家兔心臟的心室壓力系統.該系統通過計算機控制壓力,不僅能模擬正常生理條件下左心室的壓力波形,還能在心室活動周期的特定時相、以適當波形對心室施加機械刺激.該系統集心臟灌與起搏、表面心圖記錄、單相動作記錄、心室壓力制與測定等多種功能於一體,特別適用於器官水平上觀察機械反饋現象並探討其機制
  4. Under the condition of ead generation, the low and high membrane level - 25 and - 55mv of voltage were clamped during the repolarization phase of action potential. on low membrane level of - 25mv, a slow inward current similar to

    在低鉀灌並伴有ead的情況下,于動作復極相的低及高處- 25與- 55mv分別進行制。
  5. However these converters become more complicate. phase - shift zvs technique has been used in bidirectional dc / dc converters since it can realize zvs for all switches without auxiliary switches. however when the amplitude of input voltage is not matched with that of output voltage, the current stresses and rms currents of the converters become higher, in addition the converters can not achieve zvs under light - load condition

    諧振、準諧振或多諧振技術方案,變換器的應力較高,變頻控制增加了濾波器設計的難度;能量緩沖吸收路或有源路方案,由於需要增加多個額外輔助元件,增加了變換器的復雜性;全橋相移技術方案,由於主路無需增加額外元件,只需利用相移控制,即可實現軟開關,因此引起關注。
  6. With holding potential of - - 80mv depolarization beyond - - 30 mv elicited an inward current, peak at + l0 ~ + 20mv and reversed between + 50 mv and + 60mv the peak current was - - 58. 0i l3. 4 pa ( n = 7 )

    將細胞膜制在e0mv階躍性去極化刺激超過l0mv時引導出內向性鈣,峰值在去極化刺激至10 20mv時出現,翻轉在去極化刺激50一、 60mv時出現,峰值平均值為58刀士13
分享友人