鐵心繞組 的英文怎麼說

中文拼音 [tiěxīnrào]
鐵心繞組 英文
cored winding
  • : Ⅰ名詞1 (金屬元素) iron (fe) 2 (指刀槍等) arms; weapon 3 (姓氏) a surname Ⅱ形容詞1 (形容...
  • : 繞名詞1. [書面語] (彎曲) bend2. (姓氏) a surname
  • : Ⅰ名詞1 (由不多的人員組成的單位) group 2 (姓氏) a surname Ⅱ動詞(組織) organize; form Ⅲ量詞(...
  1. Analysis for magnetic field of srm is very complicated since the flux waveforms in different parts of the motor vary with motor phase, stator pole and rotor number, also with the winding connections, etc, which results in the srm losses, especially iron loss calculation difficult. the temperature analysis due to the losses has become a study hot spot

    Sr電機的磁通波形不僅與電機的相數有關,還與定、轉子齒極數、定子連接方式等密切相關,從而使得sr電機磁場分析很復雜,復雜的磁通密度波形導致電機損耗特別是損的計算非常困難。電機的損耗又會引起電機的溫升,因此高性能的sr電機的熱分析也成為目前的研究熱點。
  2. 4. to get the motor ' s performance by calculation with known formulas, as a result an adjustment for the motor ' s configuration can be practised. when a combined method of altering the length of armature, the number of turns in the winding and the dimension of permanent magnet is used. 5. to get the motor ' s performance when it is driven by the power converter. finally, the calculated data are compared with the experimental measurements, so as to verify the rationality and reliability of the method

    Q採用數值分析直軸負載磁場和交軸電樞反應磁場的方法來計算,得到較為準確的結果;根據電機工作特性的計算公式計算電機性能,由計算結果調整電機的結構,而調整工作使用改變電機長度、匝數和永磁體尺寸相結合的方法,這樣可以得到較為理想的結果;對變頻電源供電時電機的工作特性進行計算,以檢驗其變頻時的性能。
  3. The no - loading emf of prototype and the no - loading emf of conventional generator are contrasted and analyzed, in the condition of considering the influence of damping winding and core saturation

    並在考慮飽和、考慮阻尼影響情況下,將傳統發電機的空載電勢與電力發生器樣機的空載電勢進行了比較、分析。
  4. Considering the influence of damping winding and if core is saturated or not, the no - loading emf waveform of a conventional generator having the same size with the prototype ( except the stator slot ) is analyzed, and the waveform deviation factor is taken out

    對一臺具有與電力發生器樣機相同尺寸(除定子槽形)傳統發電機的空載電勢波形進行了分析。分析了不考慮飽和、考慮阻尼影響和考慮飽和、考慮阻尼影響兩種情況下,它的空載感應電勢,求取了空載電勢波形畸變率。
  5. According to the no - loading waveform deviation factor, the prototype conforms to the national design standard and practical needs in the engineering. more important, the high voltage is achieved. in the condition of considering core saturation and damping winding influence, the influence to powerformer of the no - loading tooth harmonic emf is smaller than conventional generator, and the waveform deviation factor of the former is smaller, too

    由求得的樣機空載電勢波形畸變率可知,該樣機滿足國家設計標準和工程實用要求,更重要的是,實現了產生高壓的目的;考慮飽和、考慮阻尼影響情況時,電力發生器與具有相同尺寸(除定子槽形)的傳統發電機相比,空載齒諧波電勢對電力發生器的影響較小,前者的空載波形畸變率較小。
  6. As a new kind of motor, switched reluctance motor ( srm ) has a doubly salient structure, and its windings are only mounted on the stators. these characteristics bring srm lots of virtues : solid structure, high reliability and efficiency, good fault - tolerance, low cost etc. switched reluctance driver ( srd ) combined srm with modern power electronic technology and control technology

    開關磁阻電機( srm )作為調速電動機的新品種,採用定、轉子雙凸極結構,並且只在定子上裝有集中,轉子上無或永磁體,具有結構簡單堅固、運行可靠、效率高、功率變換簡單、容錯性好和成本低等優點。
  7. The series of current transformers are resin insulated , fully enclosed and busbar type. the iron core is circular and the secondary winding goes around the core before casting by epoxy

    本型電流互感器的為圓環形,二次制在圓周上,用環氧樹脂混合料澆注成形。
  8. The thermal model used in this paper can figure out the temperature rise of the winding and core respectively

    本文採用的熱模型包含兩個熱源和三個熱阻,可以分別計算出平面變壓器的溫升。
  9. The three - phase to four - phase transformer with a four - phase four - leg structure solves the problem. the windings on each leg of this transformer are not more than three

    這種變壓器每相柱上的不超過三個,是不等相變換的最簡單形式。
  10. The iron core of the product is annular. the secondary winding go uniformity around the core. the clip clamps the core

    本型零序電流互感器的為環形,二次均勻制在上,用夾件夾緊,夾件備有安裝孔。
  11. In order to improve the veracity of pttdm, it ' s necessary to correctly calculate the planar transformer ' s heat sources which include the winding and core losses

    為了提高平面變壓器熱設計方法的準確性,必須比較準確的計算平面變壓器的熱源,即變壓器的損耗。