間輻板 的英文怎麼說

中文拼音 [jiānbǎn]
間輻板 英文
interradial plate
  • : 間Ⅰ名詞1 (中間) between; among 2 (一定的空間或時間里) with a definite time or space 3 (一間...
  • : 名詞(車輪中車轂和輪圈的連接物) spoke
  • : Ⅰ名詞1 (片狀硬物體) board; plank; plate 2 (專指店鋪的門板) shutter 3 [音樂] (打拍子的樂器) ...
  1. It does not need much area, not any pollution, not consuming much electricity power, not need much cost. gshp combined floor radiation air - conditioning system possess high seasonal average cop value and great capacity of edaphic depositing heat energy, can ease up supplied water temperature fluctuating with the change of the outdoor air temperature

    地源熱泵技術聯合地射對房進行冷暖聯供的形式,具有地源熱泵季節性平均性能系數高、土壤蓄熱能力強、能緩解空氣源熱泵存在的供冷供熱能力隨環境溫度波動大的矛盾等優點。
  2. In this study, lexa mutant of deinococcus radiodurans xe has been successfully constructed. the survival curve of this strain was measured using colony formation assay after treatment with different doses of radiation and different times of mmc

    本研究利用已構建的抗射菌lexa基因突變體菌株xe ,經受不同劑量射線照射和不同時的mmc作用,平菌落計數,繪制存活曲線。
  3. At last, there is a practical design of gshp - radiant system in a villa in chongqing. the compare of the gas - heater radiant floor system and the gshp radiant floor system indicates that the heating performance coefficient of the gshp is higher than the gas - heater to a large extent. in addition, this united system can use the closed circling water in the underground heat exchanger to remove the surplus heat load in transitional season

    通過燃氣熱水器制熱的射地供暖與地源熱泵制熱的射地供暖性能實驗的對比,可以看出地源熱泵的供熱性能系數高於燃氣熱水器,同時在長江中下游地區還可在過渡季節利用閉式循環水吸收土壤冷量對房進行供冷,提高系統運行的經濟性。
  4. Using the matlab tools, a computer program is compiled to solve this mathematic model, by which simulations to the thermal environment of the heated space under different heating style are carried out. the simulations results and their analysis show that for different space with the same thermal comfort index, the energy consumption of low - temperature water floor radiant heating system is less than that of convection heating system

    基於上述採暖空的熱網模型,運用matlab數學軟體編程,對低溫熱水地射採暖方式和對流採暖方式下房的熱環境進行動態分析,並對這兩種採暖方式下採暖系統的能耗進行計算機模擬計算,結果表明低溫熱水地射採暖系統相對于對流採暖系統有顯著的節能性。
  5. Between glass - cover board and endothermic board, honeycomb is placed, which can eliminate heat loss caused by air natural convection and greatly reduce heat loss caused by radiation, and hence a better transfer heat efficiency

    而在透明玻璃蓋和吸熱放置蜂窩結構,基本上能消除吸收表面和蓋的空氣自然對流熱損失,並可大大降低射損失,顯著提高集熱器的熱轉換效率。
  6. The simplified dynamic models for radiant floor heating are developed. the effect of row distance between the tubes on temperatures are analyzed by using the models

    摘要給出了低溫地射供冷暖的簡化動態模型,作為模型使用的實例,研究分析了地供冷時管距對各項溫度的影響。
  7. Given the thermal physical parameters of the envelops and the weather data, the above two parameters are determined by the following system design parameters : radiant panel dimension, radiant panel location and radiant panel layout style ( center or peripheral ). based on the thermal net model, digital analysis of the energy consumption and thermal environment are carried out to the several representative spaces under different design parameters, through which the relations of the heating load to the design parameters are obtained and can be a reference in the practical system design

    對于給定圍護結構熱物性參數和室外氣候參數的條件下,室內平均射溫度和室內空氣溫度的大小取決于系統的設計參數:的布置方式(周邊布置和中心布置) 、尺寸和鋪設位置。基於熱網模型,利用matlab軟體編程對採暖空在不同設計參數下室內的熱環境和能耗進行數值分析,得出了低溫熱水地射採暖系統的性能和能耗指標隨這些參數變化的規律,從而為低溫熱水地射採暖系統的優化設計提供了參考。
  8. We should pay attention to the choice of the floor material to lower the impact of solar radiation

    同時,採用置換通風與冷卻頂系統的房,對于地材料應該選擇對長波射吸收較低的物質,以減小太陽射的影響。
  9. When the element of array is near enough, the stacked tem - horn array can improve the radiation of lower frequency

    當陣列疊狀排列並且相鄰陣列單元極距較小時,可以改善低頻射特性。
  10. An array of benefits is provided with the application of the integrated system, such as high cop & spf, energy saving, small fluctuation with the ambient temperature, improving the conflict between the fresh air supply and energy consumption and etc. 3. a comparison has been made on ground - source heat pump ( gshp ) with the air - source heat pump ( ashp )

    地源熱泵聯合射地對房進行冷暖聯供,既具有地源熱泵季節性平均性能系數高、土壤蓄熱能力強、隨環境溫度波動小等優點,且能改善空氣源熱泵系統新風供給量與耗能之的矛盾關系。
  11. It has a very complete products line, from cat - 5, cat - 6 to cat - 7, from utp, ftp to optic - fiber, information module, patch cord and headband etc. the products number has come to more than 500. it can provide all series of cabling products for the wider users, especially, the ftp cabling system is the expertise of schneider electric. no matter it is workshop that endures strong the electromagnetism radiation interfere, or governmental organs that have high security level requirement and the cabling system can " t product electromagnetism radiation, several patent ftp technologies that schneider electric has can ensure the safety of network

    據悉,梅蘭日蘭infra +系列定位於高端客戶群體,以品質著稱,自2001年以來已在法國的本土綜合布線市場佔有率名列第一,擁有非常完整的產品線,從超5類、 6類到7類,從非屏蔽、屏蔽到光纖,以及信息模塊、跳線、面等等,產品編號已達500多個,可以為廣大的用戶提供全系列布線產品,尤其是屏蔽布線系統更是施耐德電氣的專長,無論電磁射干擾強烈的工廠生產車,還是對網路安全性要求較高、布線系統不能產生電磁射的政府機關中,施耐德電氣所擁有的多種專利屏蔽技術都能夠確保網路安全。
  12. The thermal process model of imbed pipe floor heating room at intermittent operation was set up by analyzing the thermal storage of enclosure. then, a solution method was give for it basing on duhamel theorem. the calculation results shown a good indoor thermal environment can be hold when the system, which designed on out door temperature for heating basis, operates half day in night under outer door mean temperature in winter

    對典型房的計算結果顯示:系統歇運行時,供暖系統開啟和關閉后室內溫度呈指數規律變化;當系統按供暖室外計算溫度設計,實際運行日的室外平均溫度等於供暖期室外日平均溫度時,在室外逐時溫度較低的時段低溫熱水地射供暖系統運行半天左右可滿足全天供暖室內計算溫度要求。
  13. The advantage of this air conditioning, that is energy conservation, is for energy to overheat or overcool air in traditional air conditioning is saved with radiation directly acting to human ' s body. so, the radiant heat exchange between human body and enclosure was made as main point of this paper that the radiant heat exchange model was established and the radiant heat exchanges of different human body in different sites were calculated in detail

    本空調方式的先進性,即節能性,是由於採用了射方式直接對人體進行供冷、供熱,從而省去了傳統的過度冷卻或加熱空氣所消耗的那部分能量而表現出來的;因此,本文把人與室內環境之射換熱作為一個重點,建立了等室內壁面與人體射換熱模型,並詳細計算在不同位置各人體部分與室內環境之射換熱。
  14. Compared with traditional air - conditioning, its advantages lie in thermal comfort energy efficiency free use of spacing and etc. this paper introduces the procedure and the result of the experiment of gas - heater radiant floor system and gshp radiant floor system and compares them with traditional air - conditioner. based on the analysis of the heat transfer of radiant floor, this paper uses the theory of heat transfer to establish a mathematical model and computes it with difference equation. the important factors inferred from the model such as floor surface temperature heat intensity composite heat transfer coefficient deviate from the experiment result in a small range of 20 % and fit the need of the practical use

    在分析了射地傳熱機理的基礎上,文中利用熱傳導、大空的自然對流換熱等傳熱學理論建立了射地的傳熱模型,再採用有限差分方法對模型求解,所得有關射地供冷熱性能的重要參數如地表面平均溫度、熱流密度、地表面復合換熱系數等與實測值相差在20以內,滿足工程使用要求;同時得出射地盤管供水溫度是影響地供冷熱性能的重要因素的結論。
  15. Compared the heating load ( and energy consumption ) of a same room with floor heating or radiator heating under same operative temperature. revealed the energy consumption of floor heating room could reduce 5 % ~ 10 % to radiator heating, and the heating load could reduce 10 % ~ 15 %. the main season of energy efficiency is due to no apparent high temperature zone in floor heating room, which avoid additional heat loss in outside envelopes, rather than the lower of indoor air temperature

    利用對連續供暖房溫度場的研究結果,對分別採用上述兩種供暖方式的典型房的熱負荷和能耗進行了全面分析后發現:低溫地射供暖房熱負荷比散熱器供暖房可降低10 15 ,能耗可降低5 10 ;低溫地射供暖房節能的主要原因並不是由於房空氣溫度可以降低,而是消除了室內空氣局部高溫區,避免了由此產生的在外圍護上的附加傳熱量。
  16. Set up a mathematical model for indoor thermal environment on the base of analyzing enclosure heat gain and heat loss of each envelope. programs were developed for floor heating and radiator heating respectively. due on higher surface temperature ( or mrt ) in the same room, the calculation results shown the indoor mean air temperature of heating radiator room was 1 ~ 1. 3 c higher than floor heating room under operative temperature same

    對連續供暖房的熱過程進行了分析,根據房熱過程數學模型編程計算結果顯示:由於散熱器供暖房各圍護結構內表面對人體的平均射溫度低於低溫地射供暖房,要達到相同的作用溫度,散熱器供暖室內空氣溫度應比低溫地射供暖房高1 . 0 1 . 3 。
  17. Nx series oscillating plies are made of impored superior stainless steel. the radiation area of the osscillating box is processed specially and the longebity of the box can be prolonged ober 50 % with the same effect. the products can be widely used in preor after processing for electric plating, inbruing and lacquer covering. they have the advantages of cleaning thoroughlu and operating convenientlu without collision

    Nx振系列產品振盒採用進口優質不銹鋼製作,振盒射面經過特殊處理,在不影響超聲效果的情況下,振盒壽命增加50 %以上,產品廣泛應用與電鍍、塗裝、電泳、噴漆等工藝的前處理和后處理工序,具有操作方便,清洗徹底,工件之不碰撞等特點。
  18. The author chose two typical rooms to study floor radiation heating system, analyzed change of temperature of every radiation surface in detail, and computed and analyzed the exchanged quantity of heat and room quality of room comfort. the paper analyzed the running parameters - temperature, flux, cop etc - of the gshp combined floor radiation heating system of four conditions which depend on the amounts of the turned on single vertical u - tube heat exchanger. the four conditions are as follows : condition that turning on 26 heat exchangers, condition that turning on 12 heat exchangers, condition that turning on 16 heat exchangers, condition that turning on 20 heat exchangers

    本論文選擇了兩個典型房主要對地射採暖房的各射面的溫度變化情況進行了詳細的分析,並對地的散熱量和房的舒適性進行了計算分析;並且以開啟不同數量的地源熱泵埋管換熱器進行了四個工況的測試並進行了詳細的分析和計算,分別為開啟全部地下埋管、開啟埋管12組、開啟埋管16組、開啟埋管20組。
  19. Numerical simulation of 3 - dturbulence flow and heat transfer of the doors

    射採暖房三維流動與傳熱的數值模擬
  20. Discussion on lower temperature in top floor rooms using radiant floor heating system

    射供暖頂層房溫度偏低的探討
分享友人