電阻接地 的英文怎麼說

中文拼音 [diànjiēde]
電阻接地 英文
resistance grounded
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
  • 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
  • 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
  1. Furthermore, problems easy to make mistake are demonstrated, for instance, grounding resistance of large grounding grid is impedance

    研究論證了被一些研究者錯誤理解的關于大型抗、四極法及其倒相法測量結果為抗等問題。
  2. According to the topology of the substation and resistance measurements of down - leaders, the erosion diagnosis equation is built and the resistance variations of grounding grid branches are solved, and the erosion of grounding grid could be found through the fuzzy diagnosis regulation

    利用網拓撲結構圖及網引下線間的測量值,建立腐蝕診斷方程,通過求解診斷方程,計算出網支路值變化量,採用模糊診斷方法判斷出網導體腐蝕的情況。
  3. First, passive resistance network was selected as direct current biasing network, which offered direct voltage for base through the resistance voltage divider composed of two resistances, among them the upper resistance connected from the dc to base, the lower resistance connected from the base to ground. the collector connected with dc directly

    直流偏置網路採用無源網路,通過由兩個組成的分壓器為基極提供直流壓,上偏源串聯到基極,下偏從基極到,集極直
  4. Energy consume, electric strength, insulation resistance, ground conductivity, leakage current, microwave leakage, power input, normal temperature, humidity treatment, glow wire, horizontal flame, vertical flame, tracking, ball pressure, rainproof, water splash, dustproof, salt fog, endurance, motor load test, cord flexing, cord pulling, pull & torque test, lamp replacement, construction check etc

    能耗、氣強度、絕緣連續性、泄漏流、微波泄漏、功率、溫升、濕熱試驗、灼熱絲、水平燃燒、垂直燃燒、漏起痕、球壓試驗、防雨淋、防濺水、粉塵、鹽霧、耐久性(壽命)試驗、機負載試驗、源線彎折、源線提拉、拉扭力測試、燈頭互換性、安全結構檢查等。
  5. By analyses and compares, the conclusion is that it would be better to choose high resistance grounding of distribution transformer for hydro turbine in hydro power station. there is no certain conclusion for steam turbine in fossil - fired power plant. getting a clear answer to choose good generator grounding mode still needs practice and time

    經分析比較認為,在水站水輪發機組宜選用變高方式;在火廠和熱廠汽輪發機組,選用何種方式,給出明確的結論尚需理論和實踐的進一步深入。
  6. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv故障的形式、消弧線圈的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了流變化、中性點取值大小、值變化等多種影響因素的情況下,對中性點經消弧線圈和經小電阻接地方式下網的過壓水平和點短路流大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  7. Grounding resistance is important technical parameter of grounding system

    是發、變系統的重要技術指標。
  8. This project is applied to the control circuit of the frequency converter power source of for measuring ground resistance in an electric substation

    此方案成功應用於變測量變頻源控制路中。
  9. The influences of vertical grounding electrodes on grounding resistance, step and touch voltages were analyzed numerically

    採用數值計算方法分析了垂直極對系統的壓及跨步壓等的影響。
  10. It creates the model of layer soil by using the cdegs software, analyses the resistance error which is measured by traditional three - poles way, measures the grounding grids resistance and soil resistance rate of hejin power plant, creates the electromagnetic model of layer soil and grounding grids model of hejin power plant, calculates the step voltage > touch voltage n voltage distribution of earth surface in fault of hejin power plant. in the end, it compares the measuring value and calculating value of grounding grids resistance in hejin power plant

    本文利用cdegs軟體建立分層土壤模型,對傳統三極法測量誤差進行分析;對河津和土壤率進行測量;建立河津廠分層土壤磁模型和網模型;計算河津和事故狀態下跨步壓、壓和位分佈;最後對河津實測值與計算值進行比較分析。
  11. However, some unique geographical characters, such as fire grounding, bamboo grounding and treetop grounding, can cause single phase high - impedance grounding fault frequently. since the voltage drops down very little and the voltage among three phases keeps symmetric, this fault increases the difficulty of the check on this fault

    然而,由火焰、毛竹或樹梢等原因引起的單相高故障,由於壓降小、三相線間壓依然幾乎對稱,從而增加了高檢測的難度。
  12. When this fault is cutted off and the breaker is reclosed, this scheme ca n ' t start by mistake. the availability of this scheme is proved with matlab test. the single phase high - impedance grounding fault is settled properly

    Matlab模擬分析證明了該方案耐受過渡的能力強,在故障切除和重合閘時不會因出現的暫態信號而誤啟動,不受系統振蕩、頻率偏差的影響,克服了常規保護靈敏度不足的缺點,較好解決了單相高故障的難題。
  13. In mode selection of middle and large capacity units nowadays, there mainly have two types of peterson coil grounding and distribution transformer with resistor

    在現有大中型發機中性點選擇上,主要有消弧線圈方式和變高方式。
  14. The devices have many merits. they can sensitively and reliably cut off all the faults occurring in the power system. even under the critical situation, faulting on the long heavy load transmission lines through high ground resistances, the criterion based on fault components still has considerable sensibility

    此裝置的優點是:能夠靈敏、可靠的切除力系統發生的各種故障,尤其是基於故障分量的差動判據與傳統差動判據相比,在重載線路上發生各種故障,即使是高時,也具有很好的靈敏性。
  15. Firstly, we analyze the transient and steady character of single phase high - impedance grounding fault. secondly, based on wavelet analysis on checking mutational signal and direction high frequency protection theory, utilizing zero sequence current and module current, this paper provides a new scheme including fault starting element, fault phase selection element, directional element and main criterion. this scheme can bear high impedance and is immune to system surge and frequency warp, which gets over the shortcoming of the lack of sensitivity

    由於現有的保護方案無法快速有效切除此類故障,本文在詳細分析了單相高故障的穩態和暫態特性的基礎上,從小波分析原理出發,利用小波變換檢測突變信號的原理,以零序流、模流等為研究對象,結合方向高頻保護的原理,設計了一套包含啟動元件、選相元件、方向元件、主保護的保護新方案。
  16. Have studied generator ground model mostly used in detail for middle and big domestic generator units. calculates and deduces fault current as grounding of single phase and third harmonic fault protection schemes. first time contributes overall knowledge about generator neutral grounding of distribution transformer with secondary resistor, in which considered inductance of the transformer to people

    針對大中型發機的兩種主要方式進行了分析,進行了故障流、三次諧波保護的計算推導,首次在變高方式有關公式推導中計入變感抗,從而使人們對變高認識更為全面。
  17. In this paper, the research was made to solute these problems. the peterson coil compensation system has been designed which can measure capacitor current and damp degree ; a fault selection method of distribution network which was put forward that based on ftu

    本課題就這兩方面的問題進行了深入研究,設計了一種消弧線圈自動補償裝置,該裝置可測量系統對流和尼率,具有響應快、準確性高的優點;同時提出了一種基於ftu的配選線方法。
  18. Manufacturer of analog switches, capacitors, diodes, inductors, integrated modules, power ics, leds, power mosfets, resistors and thermistors

    -生產由非金屬材料製成的用降劑防雷降模塊降模塊。
  19. The machine contain main functions of four testing apparatus, it can automatic test leaking current, grounding electric resistance, dielectric intensity, resting voltage and print testing data

    詳細說明具備四種測試儀的全部主要技術性能,可連續自動測試漏流、抗、介質強度、剩餘壓。可列印測試數據。
  20. The paper provides scientific method and explains for decreasing grounding resistance in a limited, high soil resistivity area by using kongfu grounding equipment

    為空腹式裝置在高土壤區或網面積較小的情況下的降提供科學的依據。
分享友人